Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
img1209-schedule-finish-5verified · printed
printed_finish_number
FINISH NO.55 finish-mark
Printed schedule row/property only. Right-edge clipped continuation preserved explicitly; no installed quantity inference. Source crops: x1780,y0,w420,h1650 (whole column); x1840,y220,w360,h620 (general); x1820,y800,w380,h830 (marble). Coordinates map source x=x0+u*w,y=y0+v*h; normalized by2200,1650.
IMG_1209 · W-4 · Locate on drawing ↗Drawing notation: FINISH NO.5
Printed schedule row/property only. Right-edge clipped continuation preserved explicitly; no installed quantity inference. Source crops: x1780,y0,w420,h1650 (whole column); x1840,y220,w360,h620 (general); x1820,y800,w380,h830 (marble). Coordinates map source x=x0+u*w,y=y0+v*h; normalized by2200,1650.
img1209-schedule-finish-5verified · printed
applicability
VAULTSPrinted schedule row/property only. Right-edge clipped continuation preserved explicitly; no installed quantity inference. Source crops: x1780,y0,w420,h1650 (whole column); x1840,y220,w360,h620 (general); x1820,y800,w380,h830 (marble). Coordinates map source x=x0+u*w,y=y0+v*h; normalized by2200,1650.
IMG_1209 · W-4 · Locate on drawing ↗Drawing notation: VAULTS
Printed schedule row/property only. Right-edge clipped continuation preserved explicitly; no installed quantity inference. Source crops: x1780,y0,w420,h1650 (whole column); x1840,y220,w360,h620 (general); x1820,y800,w380,h830 (marble). Coordinates map source x=x0+u*w,y=y0+v*h; normalized by2200,1650.
img1209-schedule-finish-5verified · printed
floor_material
CEMENT FLOORPrinted schedule row/property only. Right-edge clipped continuation preserved explicitly; no installed quantity inference. Source crops: x1780,y0,w420,h1650 (whole column); x1840,y220,w360,h620 (general); x1820,y800,w380,h830 (marble). Coordinates map source x=x0+u*w,y=y0+v*h; normalized by2200,1650.
IMG_1209 · W-4 · Locate on drawing ↗Drawing notation: CEMENT FLOOR
Printed schedule row/property only. Right-edge clipped continuation preserved explicitly; no installed quantity inference. Source crops: x1780,y0,w420,h1650 (whole column); x1840,y220,w360,h620 (general); x1820,y800,w380,h830 (marble). Coordinates map source x=x0+u*w,y=y0+v*h; normalized by2200,1650.
img1209-schedule-finish-5verified · printed
wall_material
REINFORCED CONCRETE WALLSPrinted schedule row/property only. Right-edge clipped continuation preserved explicitly; no installed quantity inference. Source crops: x1780,y0,w420,h1650 (whole column); x1840,y220,w360,h620 (general); x1820,y800,w380,h830 (marble). Coordinates map source x=x0+u*w,y=y0+v*h; normalized by2200,1650.
IMG_1209 · W-4 · Locate on drawing ↗Drawing notation: REINFORCED CONCRETE WALLS
Printed schedule row/property only. Right-edge clipped continuation preserved explicitly; no installed quantity inference. Source crops: x1780,y0,w420,h1650 (whole column); x1840,y220,w360,h620 (general); x1820,y800,w380,h830 (marble). Coordinates map source x=x0+u*w,y=y0+v*h; normalized by2200,1650.
img1209-schedule-finish-5verified · printed
ceiling_material
CEILING SLABPrinted schedule row/property only. Right-edge clipped continuation preserved explicitly; no installed quantity inference. Source crops: x1780,y0,w420,h1650 (whole column); x1840,y220,w360,h620 (general); x1820,y800,w380,h830 (marble). Coordinates map source x=x0+u*w,y=y0+v*h; normalized by2200,1650.
IMG_1209 · W-4 · Locate on drawing ↗Drawing notation: CEILING SLAB
Printed schedule row/property only. Right-edge clipped continuation preserved explicitly; no installed quantity inference. Source crops: x1780,y0,w420,h1650 (whole column); x1840,y220,w360,h620 (general); x1820,y800,w380,h830 (marble). Coordinates map source x=x0+u*w,y=y0+v*h; normalized by2200,1650.
img1209-schedule-finish-5unreviewed · printed
top_wall_ceiling_unresolved
TOP OF CEILING SLAB ... ABOVE ... FLOOR ... TO WALLS ABOVE ... WALLS AND CEILING ...Printed schedule row/property only. Right-edge clipped continuation preserved explicitly; no installed quantity inference. Source crops: x1780,y0,w420,h1650 (whole column); x1840,y220,w360,h620 (general); x1820,y800,w380,h830 (marble). Coordinates map source x=x0+u*w,y=y0+v*h; normalized by2200,1650.
IMG_1209 · W-4 · Locate on drawing ↗Drawing notation: TOP OF CEILING SLAB ... ABOVE ... FLOOR ... TO WALLS ABOVE ... WALLS AND CEILING ...
Printed schedule row/property only. Right-edge clipped continuation preserved explicitly; no installed quantity inference. Source crops: x1780,y0,w420,h1650 (whole column); x1840,y220,w360,h620 (general); x1820,y800,w380,h830 (marble). Coordinates map source x=x0+u*w,y=y0+v*h; normalized by2200,1650.
img1209-schedule-finish-5verified · printed
vault_floor_material
CEMENT FLOORFinish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
IMG_1207 · W-4 · Locate on drawing ↗Drawing notation: CEMENT FLOOR
Finish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
img1209-schedule-finish-5verified · printed
vault_wall_and_slab_material
6" REINFORCED CONCRETE WALLS AND CEILING SLABFinish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
IMG_1207 · W-4 · Locate on drawing ↗Drawing notation: 6" REINFORCED CONCRETE WALLS AND CEILING SLAB
Finish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
img1209-schedule-finish-5verified · printed
vault_concrete_note_thickness
6" REINFORCED CONCRETE WALLS AND CEILING SLAB6 in
Finish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
IMG_1207 · W-4 · Locate on drawing ↗Drawing notation: 6" REINFORCED CONCRETE WALLS AND CEILING SLAB
Finish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
img1209-schedule-finish-5verified · printed
vault_ceiling_slab_top_relative_height
TOP OF CEILING SLAB 8'6" ABOVE FINISHED FLOOR102 in
Finish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
IMG_1207 · W-4 · Locate on drawing ↗Drawing notation: TOP OF CEILING SLAB 8'6" ABOVE FINISHED FLOOR
Finish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
img1209-schedule-finish-5verified · printed
vault_upper_wall_note_thickness
4" T.C. WALLS ABOVE4 in
Finish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
IMG_1207 · W-4 · Locate on drawing ↗Drawing notation: 4" T.C. WALLS ABOVE
Finish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
img1209-schedule-finish-5verified · printed
vault_plaster_above
WALLS AND CEILING UNPLASTERED; WALLS ABOVE PLASTEREDFinish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
IMG_1207 · W-4 · Locate on drawing ↗Drawing notation: WALLS AND CEILING UNPLASTERED; WALLS ABOVE PLASTERED
Finish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
img1209-schedule-finish-5verified · printed
vault_damp_proof_paint
WALLS, CEILING AND FLOOR PAINT WITH DAMP-PROOF PAINTFinish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
IMG_1207 · W-4 · Locate on drawing ↗Drawing notation: WALLS, CEILING AND FLOOR PAINT WITH DAMP-PROOF PAINT
Finish No.5 VAULTS type row. Ceiling-slab top is a relative source note, not underside ceiling height; no reinforcement, slab span or installed vault geometry inferred. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.