footing size · width
150 in150 in
Drawing notation: 12'6" wide × 2'2"
Extraction confidence: medium-high.
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Object: pad · 7
Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
150 in
Drawing notation: 12'6" wide × 2'2"
Extraction confidence: medium-high.
Numeric value unresolved
Drawing notation: 12'6" wide × 2'2"
Extraction confidence: medium-high.
26 in
Drawing notation: 12'6" wide × 2'2"
Extraction confidence: medium-high.
150 in
Width-only schedule cell; this is not a 12′6″ square. Source audit state: checked-master-crop-single-reader.
Drawing notation: 7; 12′6″ wide × 2′2″; cap 7′4″ × 8′4″ × 1′4[?]″; reinforcement do
Calculated from: foundation-main-7-footing-widthInches
Numeric value unresolved
Longitudinal length is not stated in this schedule row. Source audit state: unresolved.
Drawing notation: 7; 12′6″ wide × 2′2″; cap 7′4″ × 8′4″ × 1′4[?]″; reinforcement do
Calculated from: foundation-main-7-footing-lengthInches
0 deg
The strip's longitudinal edges run parallel to Madison/world X. This establishes run direction, not a numeric longitudinal extent. Source audit state: checked-master-crop-single-reader.
Drawing notation: 7; (-11′6″); strip edges run along Madison; longitudinal break lines
90 deg
The scheduled width crosses the strip along world Z. Source audit state: checked-master-crop-single-reader.
Drawing notation: 7; (-11′6″); strip edges run along Madison; longitudinal break lines
Drawing notation: 7; 12′6″ wide × 2′2″; cap 7′4″ × 8′4″ × 1′4[?]″; reinforcement do
Calculated from: footing-7-placement-strip-run-axis
12.5 ft
Source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: 7; 12′6″ wide × 2′2″; cap 7′4″ × 8′4″ × 1′4[?]″; reinforcement do
Drawing notation: 7; (-11′6″); strip edges run along Madison; longitudinal break lines
Calculated from: footing-7-placement-schedule-width, footing-7-placement-width-axis
Numeric value unresolved
No numeric end/step location or longitudinal length was identified. Column bay dimensions are not footing end dimensions. Source audit state: unresolved.
Drawing notation: 7; (-11′6″); strip edges run along Madison; longitudinal break lines
Drawing notation: 7; 12′6″ wide × 2′2″; cap 7′4″ × 8′4″ × 1′4[?]″; reinforcement do
Calculated from: footing-7-placement-schedule-length
Numeric value unresolved
Strip run is X, but an individual segment's longest side is not asserted while its X length is unknown. Source audit state: unresolved.
Drawing notation: 7; (-11′6″); strip edges run along Madison; longitudinal break lines
Drawing notation: 7; 12′6″ wide × 2′2″; cap 7′4″ × 8′4″ × 1′4[?]″; reinforcement do
Calculated from: footing-7-placement-span-x, footing-7-placement-span-z
2.166667 ft
Source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: 7; 12′6″ wide × 2′2″; cap 7′4″ × 8′4″ × 1′4[?]″; reinforcement do
Calculated from: foundation-main-7-footing-thicknessInches
C7 is explicitly printed in the header carrying suffix c. Applicability is to this printed mark, not inferred from C5. Source audit state: reused-source-header-reviewed-for-this-mark.
Drawing notation: C5; C6; C7; c
2.75 in
The existing crop/text record explicitly includes this mark and c = 2¾″. No C5 offset measurement is used as a parent. Source audit state: reused-previously-audited-W409-header-key; not-new-image-review.
Drawing notation: C5; C6; C7; c
Drawing notation: c = 2¾″; OF FOOTINGS FROM ℄ OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Drawing notation: DISTANCES OF C. of G. OF FOOTINGS FROM C.L. OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Calculated from: footing-7-placement-e-suffix
-1 sign
Independently followed the actual C7 plan's two centerlines: footing above steel. Upright page-up is south/−Z. A detached typical diagram is not used for this sign. Source audit state: checked-master-crop-single-reader.
Drawing notation: 7; ℄ FOOTING; ℄ STEEL COL.; upper footing and lower steel centerline
Drawing notation: ℄ FOOTING; ℄ STEEL COL.
Drawing notation: 7; (-11′6″); strip edges run along Madison; longitudinal break lines
-2.75 in
This resolves the transverse offset only; longitudinal strip-segment centroid is not established. Source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: 7; ℄ FOOTING; ℄ STEEL COL.; upper footing and lower steel centerline
Drawing notation: C5; C6; C7; c
Drawing notation: c = 2¾″; OF FOOTINGS FROM ℄ OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Calculated from: footing-7-placement-offset-z-sign, footing-7-placement-eccentricity-magnitude
Numeric value unresolved
Undimensioned longitudinal break locations prevent a documented segment centroid; no zero X offset is assumed. Source audit state: unresolved.
Drawing notation: 7; (-11′6″); strip edges run along Madison; longitudinal break lines
Numeric value unresolved
Column control X is 7 ft. It is not substituted for an unestablished segment center. Source audit state: blocked-by-missing-longitudinal-extent.
Drawing notation: C7; printed perimeter bay chain
Drawing notation: 7; (-11′6″); strip edges run along Madison; longitudinal break lines
Calculated from: column-7-registered-world-x, footing-7-placement-offset-x
-78.8125 ft
Transverse axis only; full 3D footing center remains incomplete. Source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: C7; printed perimeter bay chain
Drawing notation: 7; ℄ FOOTING; ℄ STEEL COL.; upper footing and lower steel centerline
Drawing notation: C5; C6; C7; c
Drawing notation: c = 2¾″; OF FOOTINGS FROM ℄ OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Calculated from: column-7-registered-world-z, footing-7-placement-offset-z
-85.0625 ft
Cross-strip envelope bound; does not define a finite box without X bounds. Source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: 7; 12′6″ wide × 2′2″; cap 7′4″ × 8′4″ × 1′4[?]″; reinforcement do
Drawing notation: 7; (-11′6″); strip edges run along Madison; longitudinal break lines
Drawing notation: C5; C6; C7; c
Drawing notation: c = 2¾″; OF FOOTINGS FROM ℄ OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Calculated from: footing-7-placement-center-z, footing-7-placement-span-z
-72.5625 ft
Cross-strip envelope bound; does not define a finite box without X bounds. Source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: 7; 12′6″ wide × 2′2″; cap 7′4″ × 8′4″ × 1′4[?]″; reinforcement do
Drawing notation: 7; (-11′6″); strip edges run along Madison; longitudinal break lines
Drawing notation: C5; C6; C7; c
Drawing notation: c = 2¾″; OF FOOTINGS FROM ℄ OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Calculated from: footing-7-placement-center-z, footing-7-placement-span-z
Numeric value unresolved
Longitudinal end/break not dimensioned in the inspected region. Source audit state: unresolved.
Drawing notation: 7; (-11′6″); strip edges run along Madison; longitudinal break lines
Numeric value unresolved
Longitudinal end/break not dimensioned in the inspected region. Source audit state: unresolved.
Drawing notation: 7; (-11′6″); strip edges run along Madison; longitudinal break lines
68.75 ft
Source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: (-11′6″)
Drawing notation: 7; (-11′6″); strip edges run along Madison; longitudinal break lines
Calculated from: foundation-finished-basement-floor-elevationFeet, foundation-main-7-bottomElevation-inchesRelativeToFinishedBasementFloor
70.916667 ft
Source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: (-11′6″)
Drawing notation: 7; 12′6″ wide × 2′2″; cap 7′4″ × 8′4″ × 1′4[?]″; reinforcement do
Calculated from: footing-7-placement-bottom-el, footing-7-placement-thickness
69.833333 ft
Source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: (-11′6″)
Drawing notation: 7; 12′6″ wide × 2′2″; cap 7′4″ × 8′4″ × 1′4[?]″; reinforcement do
Calculated from: footing-7-placement-bottom-el, footing-7-placement-top-el
Source inventory is separate from the floor filters above. Select one drawing to inspect it; no drawing set is preloaded.