footing size · width
48 in48 in
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Object: pad · 3
Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
48 in
48 in
Calculated from: foundation-main-3-footing-widthInches
18 in
0 degree
Nominal footing envelope only; source audit state: checked-master-crop-single-reader. Square edges follow the Madison axes; rotation is modulo 90°, with no distinct long/short axis.
Drawing notation: 3; (-6′0″); square footprint around concrete pilaster
Numeric value unresolved
Nominal footing envelope only; source audit state: not-applicable-square. Not applicable to a 4′ square; no long axis is invented.
Drawing notation: 3; (-6′0″); square footprint around concrete pilaster
Drawing notation: 3; 4′0″□ × 1′6″; cap: do
4 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: 3; 4′0″□ × 1′6″; cap: do
Drawing notation: 3; (-6′0″); square footprint around concrete pilaster
Calculated from: foundation-main-3-footing-widthInches, footing-3-placement-plan-axis
4 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: 3; 4′0″□ × 1′6″; cap: do
Drawing notation: 3; (-6′0″); square footprint around concrete pilaster
Calculated from: foundation-main-3-footing-lengthInches, footing-3-placement-plan-axis
1.5 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: 3; 4′0″□ × 1′6″; cap: do
Calculated from: foundation-main-3-footing-thicknessInches
Nominal footing envelope only; source audit state: checked-blank-header; magnitude-unresolved. C3's suffix band is blank in the inspected W409 header. This does not establish E = 0.
Drawing notation: C3; suffix area blank in inspected header
Numeric value unresolved
Nominal footing envelope only; source audit state: unresolved. No C3 suffix-to-key assignment was found. No value is borrowed from C4 or C5.
Drawing notation: C3; suffix area blank in inspected header
Drawing notation: c = 2¾″; OF FOOTINGS FROM ℄ OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Drawing notation: DISTANCES OF C. of G. OF FOOTINGS FROM C.L. OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Calculated from: footing-3-placement-e-suffix
Numeric value unresolved
Nominal footing envelope only; source audit state: unresolved. Small pilaster/footing symbol appears aligned with the column axis, but no independent dimension establishes an exact X offset. Apparent centering is not promoted to zero.
Drawing notation: 3; (-6′0″); square footprint around concrete pilaster
Numeric value unresolved
Nominal footing envelope only; source audit state: unresolved. The C3 small pilaster/footing condition differs from the larger C4/C5 pads. The labeled line pair is not sufficient to assign C3 a numeric offset or an independently established sign.
Drawing notation: 3; (-6′0″); square footprint around concrete pilaster
Drawing notation: C3; suffix area blank in inspected header
Numeric value unresolved
Nominal footing envelope only; source audit state: unresolved. No signed offset assigned.
Drawing notation: 3; (-6′0″); square footprint around concrete pilaster
Drawing notation: C3; suffix area blank in inspected header
Drawing notation: c = 2¾″; OF FOOTINGS FROM ℄ OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Calculated from: footing-3-placement-eccentricity-magnitude, footing-3-placement-offset-z-sign
Numeric value unresolved
Nominal footing envelope only; source audit state: blocked-by-missing-offset. Column control is −49 ft; footing center remains null.
Drawing notation: C3; perimeter column bay chain
Drawing notation: 3; (-6′0″); square footprint around concrete pilaster
Calculated from: column-3-registered-world-x, footing-3-placement-offset-x
Numeric value unresolved
Nominal footing envelope only; source audit state: blocked-by-missing-offset. Column control is −78′7″; footing center remains null.
Drawing notation: C3; perimeter column bay chain
Drawing notation: 3; (-6′0″); square footprint around concrete pilaster
Calculated from: column-3-registered-world-z, footing-3-placement-offset-z
74.25 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: (-6′0″)
Calculated from: foundation-finished-basement-floor-elevationFeet, foundation-main-3-bottomElevation-inchesRelativeToFinishedBasementFloor
75.75 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: (-6′0″)
Drawing notation: 3; 4′0″□ × 1′6″; cap: do
Calculated from: footing-3-placement-bottom-el, footing-3-placement-thickness
75 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: (-6′0″)
Drawing notation: 3; 4′0″□ × 1′6″; cap: do
Calculated from: footing-3-placement-bottom-el, footing-3-placement-top-el
Source inventory is separate from the floor filters above. Select one drawing to inspect it; no drawing set is preloaded.