footing size · width
156 in156 in
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Object: pad · 14
Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
156 in
156 in
Calculated from: foundation-main-14-footing-widthInches
27 in
13 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: 13′0″ □ × 2′3″
checked selected master crop, single reader; bounded C13–C15 gate, not an accepted world box.
13 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: 13′0″ □ × 2′3″
checked selected master crop, single reader; bounded C13–C15 gate, not an accepted world box.
2.25 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: 2′3″
checked selected master crop, single reader; bounded C13–C15 gate, not an accepted world box.
-5.833333 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: (−5′10″)
checked selected master crop, single reader; bounded C13–C15 gate, not an accepted world box.
74.416667 EL ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
arithmetic checked; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f14-bottom-depth
76.666667 EL ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
arithmetic checked; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f14-bottom-el, gate-c13-c15-f14-thickness
Numeric value unresolved
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
withheld; bounded C13–C15 gate, not an accepted world box.
Numeric value unresolved
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
withheld; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f14-e-mark
Numeric value unresolved
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
withheld; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f14-e-mark
Numeric value unresolved
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
withheld; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f14-column-x, gate-c13-c15-f14-offset-x
Numeric value unresolved
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
withheld; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f14-column-z, gate-c13-c15-f14-offset-z
Source inventory is separate from the floor filters above. Select one drawing to inspect it; no drawing set is preloaded.