footing size · width
144 in144 in
Drawing notation: 12'0" × 14'0" × 2'3"
Extraction confidence: medium-high.
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Object: pad · 13
Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
144 in
Drawing notation: 12'0" × 14'0" × 2'3"
Extraction confidence: medium-high.
168 in
Drawing notation: 12'0" × 14'0" × 2'3"
Extraction confidence: medium-high.
27 in
Drawing notation: 12'0" × 14'0" × 2'3"
Extraction confidence: medium-high.
12 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: 12′0″ × 14′0″ × 2′3″
checked selected master crop, single reader; bounded C13–C15 gate, not an accepted world box.
14 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: 12′0″ × 14′0″ × 2′3″
checked selected master crop, single reader; bounded C13–C15 gate, not an accepted world box.
12 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: 12′0″ × 14′0″; plan gives 7′0″ + 7′0″ in Z
checked selected master crop, single reader; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f13-side-a, gate-c13-c15-f13-side-b, gate-c13-c15-f13-z-equal-halves
14 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: 7′0″ + 7′0″
checked extension-line endpoints in selected master crop, single reader; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f13-side-b, gate-c13-c15-f13-z-equal-halves
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: 7′0″ + 7′0″
checked selected master crop, single reader; bounded C13–C15 gate, not an accepted world box.
2.25 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: 2′3″
checked selected master crop, single reader; bounded C13–C15 gate, not an accepted world box.
Numeric value unresolved
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
withheld; bounded C13–C15 gate, not an accepted world box.
Numeric value unresolved
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
withheld; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f13-bottom-depth
Numeric value unresolved
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
withheld; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f13-bottom-el, gate-c13-c15-f13-thickness
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: C13 / C24; d
checked selected master crop, single reader; bounded C13–C15 gate, not an accepted world box.
1.75 in
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: d = 1¾″
prior selected crop, single reader; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f13-e-mark
Numeric value unresolved
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
withheld; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f13-e-magnitude
0 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: 7′0″ north + 7′0″ south of steel row
checked selected master crop, single reader; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f13-z-equal-halves
Numeric value unresolved
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
withheld; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f13-column-x, gate-c13-c15-f13-offset-x
-56 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
one-axis placement accepted; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f13-column-z, gate-c13-c15-f13-offset-z
-63 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
one-axis placement accepted; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f13-center-z, gate-c13-c15-f13-size-z
-49 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
Drawing notation: Unresolved
one-axis placement accepted; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f13-center-z, gate-c13-c15-f13-size-z
Source inventory is separate from the floor filters above. Select one drawing to inspect it; no drawing set is preloaded.