Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
f7-room-714-img0931-millwork-enclosureverified · printed
distinct wall elevation compositions
NORTH WALL; SOUTH WALL; ELEVATION EAST WALL / WEST WALL SAME REVERSE3 count
Authoring eligible: false. Source audit state: verified-composition-count; four room walls represented.
f7-room-714-img0931-millwork-enclosureverified · printed
wood species / finish-note revision
MahoganyAuthoring eligible: false. Source audit state: verified-word; exact member scope unresolved. Conflict group: library714-img0931-wood-species-revision.
f7-room-714-img0931-millwork-enclosureunreviewed · printed
original wood species wording
UnresolvedAuthoring eligible: false. Source audit state: explicit-null. Conflict group: library714-img0931-wood-species-revision.
f7-room-714-img0931-millwork-enclosureunreviewed · printed
finish sample requirement
Stain to match approved sample ...Authoring eligible: false. Source audit state: partial; remaining words and approved sample unavailable.
f7-room-714-img0931-millwork-enclosureverified · observed
Physical Room 714 library geometry gate
FAIL — identities and selected local values onlyThe drawing explicitly requires contractor verification of measurements and job conditions. Complete wall lengths, vertical stacks, bay widths, panel/door/shelf quantities, profiles and dimension endpoints are not all readable or classified. The drawing is an oblique photograph with folds and local perspective; paper line lengths cannot be scaled safely. Original values and material words beneath yellow review markup remain obscured. The south-wall opening-like bays are not cross-walked one-to-one to f7-door-714-715 and f7-door-714-716. No fixture instances are safely classified. No checked IMG_0931 wall-elevation-to-plan or source-to-world transform exists.
f7-room-714-img0931-millwork-enclosureverified · observed
Room 714 source-to-world placement gate
FAIL — W8 is the wrong floor and IMG_1221 context is provisionalW8 / IMG_1219 is the sixth-floor plan. Room 714 is on the seventh floor, so a direct IMG_0931-to-W8 fit would be a floor-category error. W8 may inform shared building axes only through existing project conventions; it cannot place Room 714 millwork. The existing Room 714 polygon has 3.25-foot conservative uncertainty and unreviewed finish faces. IMG_0931 supplies wall-specific millwork plans/elevations but no accepted common controls, no scale-bearing whole-room plan and no checked orientation correspondence.
f7-room-714-img0931-millwork-enclosureverified · observed
Analytical coordinate-control study gate
FAIL — no safe coordinate fit from IMG_0931 aloneOnly wall strips and elevations are shown; there is no complete orthogonal room plan with accepted common control points. Folds and perspective vary across the photographed sheet. Several candidate controls are revision annotations with obscured originals. Plan/elevation endpoints are not consistently classified as finish face, frame face, track centerline or member edge. No independent held-out checks can be formed without opening and registering a companion source.
f7-room-714-img0931-millwork-enclosureverified · printed
original_exposed_material_clause
Doors and exposed parts Phil Mahogany Hard close ribbon grainOriginal white-line exposed-material clause. Phil abbreviation is literal, not expanded. It remains separate from adjacent yellow revision text. Source-local reading only; installation, revision authority and geometry remain unchecked.
IMG_0931 · Locate on drawing ↗Drawing notation: Doors and exposed parts Phil Mahogany Hard close ribbon grain
Original white-line exposed-material clause. Phil abbreviation is literal, not expanded. It remains separate from adjacent yellow revision text. Source-local reading only; installation, revision authority and geometry remain unchecked.
f7-room-714-img0931-millwork-enclosureverified · printed
original_standards_backs_material_clause
Standards and fixed nailed backs White PineOriginal white-line standards/back clause; adjacent yellow Mahogany stays separate. No installed material or revision selection. Source-local reading only; installation, revision authority and geometry remain unchecked.
IMG_0931 · Locate on drawing ↗Drawing notation: Standards and fixed nailed backs White Pine
Original white-line standards/back clause; adjacent yellow Mahogany stays separate. No installed material or revision selection. Source-local reading only; installation, revision authority and geometry remain unchecked.
f7-room-714-img0931-millwork-enclosureverified · printed
finish_sample_requirement
Stain to match approved sample for a shellac and Varnish finish by othersComplete printed source clause in this IMG0931 witness. The physical approved sample, shellac/varnish product and installed finish remain unavailable. Source-local reading only; installation, revision authority and geometry remain unchecked.
IMG_0931 · Locate on drawing ↗Drawing notation: Stain to match approved sample for a shellac and Varnish finish by others
Complete printed source clause in this IMG0931 witness. The physical approved sample, shellac/varnish product and installed finish remain unavailable. Source-local reading only; installation, revision authority and geometry remain unchecked.