Earlier reading of printed clear width
3'-0"3 ft
Superseded by the clearer duplicate photograph IMG_1156, which securely reads 3'-10" between the janitor closet inner faces.
Drawing notation: 3'-0"
W-235 seventh-floor toilet component extraction.
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Object: Janitor closet adjacent to Rooms 720–721
Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
3 ft
Superseded by the clearer duplicate photograph IMG_1156, which securely reads 3'-10" between the janitor closet inner faces.
Drawing notation: 3'-0"
W-235 seventh-floor toilet component extraction.
7 ft
Vertical dimension between the janitor closet's inner wall faces.
Drawing notation: 7'-0"
W-235 seventh-floor toilet component extraction.
6 count
Materials represented by Finish No. 6 remain unresolved until the finish schedule is correlated.
Drawing notation: FIN. NO. 6
W-235 seventh-floor toilet component extraction.
3.833333 ft
Secure duplicate-source reading between the janitor closet's inner wall faces. Supersedes the earlier disputed 3'-0" reading from IMG_1272.
Drawing notation: 3'-10"; 7'-0"
Clearer duplicate-source correction of bounded W-235 restroom readings; no fixture or wall placement is accepted.
7 ft
Independent duplicate-source corroboration of the previously recorded 7-foot clear length.
Drawing notation: 3'-10"; 7'-0"
Clearer duplicate-source correction of bounded W-235 restroom readings; no fixture or wall placement is accepted.
-67.014731 ft
Elevator-anchored W-235 source rectification. Visible overlay coordinate only; not an accepted face, partition, wall or room boundary.
Drawing notation: 3'-10"; 7'-0"
Clearer duplicate-source correction of bounded W-235 restroom readings; no fixture or wall placement is accepted.
Calculated from: w235-img1156-elevator-1-clear-width, w235-img1156-elevator-1-clear-depth, w235-img1156-elevator-1-diagnostic-center-x, w235-img1156-elevator-1-diagnostic-center-z
34.947874 ft
Elevator-anchored W-235 source rectification. Visible overlay coordinate only; not an accepted face, partition, wall or room boundary.
Drawing notation: 3'-10"; 7'-0"
Clearer duplicate-source correction of bounded W-235 restroom readings; no fixture or wall placement is accepted.
Calculated from: w235-img1156-elevator-1-clear-width, w235-img1156-elevator-1-clear-depth, w235-img1156-elevator-1-diagnostic-center-x, w235-img1156-elevator-1-diagnostic-center-z
-63.18141 ft
Elevator-anchored W-235 source rectification. Visible overlay coordinate only; not an accepted face, partition, wall or room boundary.
Drawing notation: 3'-10"; 7'-0"
Clearer duplicate-source correction of bounded W-235 restroom readings; no fixture or wall placement is accepted.
Calculated from: w235-img1156-elevator-1-clear-width, w235-img1156-elevator-1-clear-depth, w235-img1156-elevator-1-diagnostic-center-x, w235-img1156-elevator-1-diagnostic-center-z
35.055837 ft
Elevator-anchored W-235 source rectification. Visible overlay coordinate only; not an accepted face, partition, wall or room boundary.
Drawing notation: 3'-10"; 7'-0"
Clearer duplicate-source correction of bounded W-235 restroom readings; no fixture or wall placement is accepted.
Calculated from: w235-img1156-elevator-1-clear-width, w235-img1156-elevator-1-clear-depth, w235-img1156-elevator-1-diagnostic-center-x, w235-img1156-elevator-1-diagnostic-center-z
-63.21832 ft
Elevator-anchored W-235 source rectification. Visible overlay coordinate only; not an accepted face, partition, wall or room boundary.
Drawing notation: 3'-10"; 7'-0"
Clearer duplicate-source correction of bounded W-235 restroom readings; no fixture or wall placement is accepted.
Calculated from: w235-img1156-elevator-1-clear-width, w235-img1156-elevator-1-clear-depth, w235-img1156-elevator-1-diagnostic-center-x, w235-img1156-elevator-1-diagnostic-center-z
41.981897 ft
Elevator-anchored W-235 source rectification. Visible overlay coordinate only; not an accepted face, partition, wall or room boundary.
Drawing notation: 3'-10"; 7'-0"
Clearer duplicate-source correction of bounded W-235 restroom readings; no fixture or wall placement is accepted.
Calculated from: w235-img1156-elevator-1-clear-width, w235-img1156-elevator-1-clear-depth, w235-img1156-elevator-1-diagnostic-center-x, w235-img1156-elevator-1-diagnostic-center-z
-67.037833 ft
Elevator-anchored W-235 source rectification. Visible overlay coordinate only; not an accepted face, partition, wall or room boundary.
Drawing notation: 3'-10"; 7'-0"
Clearer duplicate-source correction of bounded W-235 restroom readings; no fixture or wall placement is accepted.
Calculated from: w235-img1156-elevator-1-clear-width, w235-img1156-elevator-1-clear-depth, w235-img1156-elevator-1-diagnostic-center-x, w235-img1156-elevator-1-diagnostic-center-z
41.915051 ft
Elevator-anchored W-235 source rectification. Visible overlay coordinate only; not an accepted face, partition, wall or room boundary.
Drawing notation: 3'-10"; 7'-0"
Clearer duplicate-source correction of bounded W-235 restroom readings; no fixture or wall placement is accepted.
Calculated from: w235-img1156-elevator-1-clear-width, w235-img1156-elevator-1-clear-depth, w235-img1156-elevator-1-diagnostic-center-x, w235-img1156-elevator-1-diagnostic-center-z
-67.014731 ft
Elevator-anchored W-235 source rectification. Visible overlay coordinate only; not an accepted face, partition, wall or room boundary.
Drawing notation: 3'-10"; 7'-0"
Clearer duplicate-source correction of bounded W-235 restroom readings; no fixture or wall placement is accepted.
Calculated from: w235-img1156-elevator-1-clear-width, w235-img1156-elevator-1-clear-depth, w235-img1156-elevator-1-diagnostic-center-x, w235-img1156-elevator-1-diagnostic-center-z
34.947874 ft
Elevator-anchored W-235 source rectification. Visible overlay coordinate only; not an accepted face, partition, wall or room boundary.
Drawing notation: 3'-10"; 7'-0"
Clearer duplicate-source correction of bounded W-235 restroom readings; no fixture or wall placement is accepted.
Calculated from: w235-img1156-elevator-1-clear-width, w235-img1156-elevator-1-clear-depth, w235-img1156-elevator-1-diagnostic-center-x, w235-img1156-elevator-1-diagnostic-center-z
Source inventory is separate from the floor filters above. Select one drawing to inspect it; no drawing set is preloaded.