Object: Seventh-floor Elevator No. 1 · W-235 printed clear-plan envelope
Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
f7-elevator-1-w235-clear-plan-envelopeverified · printed
Printed clear plan width
7'-4 3/4"7.395833 ft
Extension endpoints terminate at the two inner faces of the W-235 Elevator No. 1 plan rectangle.
IMG_1156 · sheet-W235 · Locate on drawing ↗Drawing notation: 7'-4 3/4"; 8'-2"
Duplicate-source photograph of W-235. Printed clear dimensions are verified; the building-centered envelope remains a diagnostic overlay only.
f7-elevator-1-w235-clear-plan-envelopeverified · printed
Printed clear plan depth
8'-2"8.166667 ft
Vertical W-235 plan dimension with secure numerals and endpoints; no shaft-wall thickness is inferred.
IMG_1156 · sheet-W235 · Locate on drawing ↗Drawing notation: 7'-4 3/4"; 8'-2"
Duplicate-source photograph of W-235. Printed clear dimensions are verified; the building-centered envelope remains a diagnostic overlay only.
f7-elevator-1-w235-clear-plan-envelopeunreviewed · derived
Diagnostic center · building west/east coordinate
-69.631 ft-69.631 ft
Display diagnostic only; not an accepted W-235 building transform.
IMG_1156 · sheet-W235 · Locate on drawing ↗Drawing notation: 7'-4 3/4"; 8'-2"
Duplicate-source photograph of W-235. Printed clear dimensions are verified; the building-centered envelope remains a diagnostic overlay only.
Calculated from: f7-elevator-1-vertex-1-west, f7-elevator-1-vertex-2-west, f7-elevator-1-vertex-3-west, f7-elevator-1-vertex-4-west
f7-elevator-1-w235-clear-plan-envelopeunreviewed · derived
Diagnostic center · building south/north coordinate
51.97425 ft51.97425 ft
Display diagnostic only; not an accepted W-235 building transform.
IMG_1156 · sheet-W235 · Locate on drawing ↗Drawing notation: 7'-4 3/4"; 8'-2"
Duplicate-source photograph of W-235. Printed clear dimensions are verified; the building-centered envelope remains a diagnostic overlay only.
Calculated from: f7-elevator-1-vertex-1-north, f7-elevator-1-vertex-2-north, f7-elevator-1-vertex-3-north, f7-elevator-1-vertex-4-north
f7-elevator-1-w235-clear-plan-envelopeunreviewed · derived
Existing provisional trace width minus printed W-235 clear width
0.8951666666666638 ft0.895167 ft
The compared boundaries are not yet proven to be corresponding wall faces.
IMG_1156 · sheet-W235 · Locate on drawing ↗Drawing notation: 7'-4 3/4"; 8'-2"
Duplicate-source photograph of W-235. Printed clear dimensions are verified; the building-centered envelope remains a diagnostic overlay only.
Calculated from: w235-img1156-elevator-1-clear-width, f7-elevator-1-footprint-trace
f7-elevator-1-w235-clear-plan-envelopeunreviewed · derived
Existing provisional trace depth minus printed W-235 clear depth
-0.32716666666665795 ft-0.327167 ft
The compared boundaries are not yet proven to be corresponding wall faces.
IMG_1156 · sheet-W235 · Locate on drawing ↗Drawing notation: 7'-4 3/4"; 8'-2"
Duplicate-source photograph of W-235. Printed clear dimensions are verified; the building-centered envelope remains a diagnostic overlay only.
Calculated from: w235-img1156-elevator-1-clear-depth, f7-elevator-1-footprint-trace
f7-elevator-1-w235-clear-plan-envelopeunreviewed · derived
Diagnostic north edge residual from W229 first-floor clear-hatch north edge
0.05758333333332821 ft0.057583 ft
Strong diagnostic alignment only. W235 clear shaft face and W229 first-floor clear-hatch edge have not yet been proven to be the same construction face.
IMG_1156 · sheet-W235 · Locate on drawing ↗Drawing notation: 7'-4 3/4"; 8'-2"
Duplicate-source photograph of W-235. Printed clear dimensions are verified; the building-centered envelope remains a diagnostic overlay only.
Calculated from: w235-img1156-elevator-1-clear-depth, w235-img1156-elevator-1-diagnostic-center-z, w229-e1-clear-hatch-north-edge-world-z
f7-elevator-1-w235-clear-plan-envelopeverified · observed
Accepted W-235 clear-envelope building transform
UnresolvedWithheld. The display envelope is centered on a provisional target trace and is not an accepted placement.
IMG_1156 · sheet-W235 · Locate on drawing ↗Drawing notation: 7'-4 3/4"; 8'-2"
Duplicate-source photograph of W-235. Printed clear dimensions are verified; the building-centered envelope remains a diagnostic overlay only.