Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
f6-stair-hall-604unreviewed · traced
Boundary vertex 1 · west
-64.963 ft (trace)-64.963 ft · estimated uncertainty ±3.25 ft
Calculated from: f6-stair-hall-604-footprint-trace
f6-stair-hall-604unreviewed · traced
Boundary vertex 1 · north
-53.2 ft (trace)-53.2 ft · estimated uncertainty ±3.25 ft
Calculated from: f6-stair-hall-604-footprint-trace
f6-stair-hall-604unreviewed · traced
Boundary vertex 2 · west
-56.994 ft (trace)-56.994 ft · estimated uncertainty ±3.25 ft
Calculated from: f6-stair-hall-604-footprint-trace
f6-stair-hall-604unreviewed · traced
Boundary vertex 2 · north
-53.267 ft (trace)-53.267 ft · estimated uncertainty ±3.25 ft
Calculated from: f6-stair-hall-604-footprint-trace
f6-stair-hall-604unreviewed · traced
Boundary vertex 3 · west
-56.45 ft (trace)-56.45 ft · estimated uncertainty ±3.25 ft
Calculated from: f6-stair-hall-604-footprint-trace
f6-stair-hall-604unreviewed · traced
Boundary vertex 3 · north
-45.286 ft (trace)-45.286 ft · estimated uncertainty ±3.25 ft
Calculated from: f6-stair-hall-604-footprint-trace
f6-stair-hall-604unreviewed · traced
Boundary vertex 4 · west
-64.86 ft (trace)-64.86 ft · estimated uncertainty ±3.25 ft
Calculated from: f6-stair-hall-604-footprint-trace
f6-stair-hall-604unreviewed · traced
Boundary vertex 4 · north
-44.959 ft (trace)-44.959 ft · estimated uncertainty ±3.25 ft
Calculated from: f6-stair-hall-604-footprint-trace
f6-stair-hall-604verified · printed
depicted_up_connection
UP 22R [private stair adjoining Hall604]Source depicts upward private stair at east/Sixth courtroom support hall604. Count retained in prior verified record; does not imply a generic whole-story flight.
IMG_1219 · W8 · Locate on drawing ↗Drawing notation: UP 22R [private stair adjoining Hall604]
Source depicts upward private stair at east/Sixth courtroom support hall604. Count retained in prior verified record; does not imply a generic whole-story flight.
f6-stair-hall-604unreviewed · inferred
seventh_floor_host_candidate
[east courtroom support stair / Stair F Room700 on floor7]East/Sixth host side, adjacent support group and complementary up/down marks support candidate Hall604-to-F700 connection. No accepted vertical transform, landing-datum closure or physical join; explicitly not asserted as installed.
IMG_1219 · W8 · Locate on drawing ↗Drawing notation: [east courtroom support stair / Stair F Room700 on floor7]
East/Sixth host side, adjacent support group and complementary up/down marks support candidate Hall604-to-F700 connection. No accepted vertical transform, landing-datum closure or physical join; explicitly not asserted as installed.