Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
f6-room-607-wall-south-millworkverified · printed
South-wall local horizontal dimension
6'-0"6 ft
The glyph string is secure. It is not used for geometry until both extension-line endpoints are assigned to stable members. Source audit state: verified-value-endpoints-unresolved. Physical geometry gate failed.
f6-room-607-wall-south-millworkverified · printed
South-wall local vertical dimension
7'-8 5/8"7.71875 ft
The glyph string is secure; exact upper and lower datum classifications remain unresolved. Source audit state: verified-value-endpoints-unresolved. Physical geometry gate failed.
f6-room-607-wall-south-millworkverified · printed
South-wall local upper vertical dimension
2'-3 1/2"2.291667 ft
The glyph string is secure; exact upper and lower datum classifications remain unresolved. Source audit state: verified-value-endpoints-unresolved. Physical geometry gate failed.
f6-room-607-wall-south-millworkunreviewed · printed
South-wall local overall vertical dimension
10'-5 3/4"10.479167 ft
The reading is strong but receives one more full-resolution endpoint/glyph check before modeling. It is not treated as clear ceiling height. Source audit state: provisional-reading-endpoints-unresolved. Physical geometry gate failed.
f6-room-607-wall-south-millworkverified · printed
Repeated south-wall local member dimension
3"3 in
The 3-inch callout repeats at narrow vertical divisions. Whether it controls a stile, filler, reveal or another member must be established before instancing. Source audit state: verified-value-member-class-unresolved. Physical geometry gate failed.
f6-room-607-wall-south-millworkverified-core-caption · printed
radiator_vent_relationship
Vents to RadiatorNumeric value unresolved
Caption under lower service plan associates vent condition with radiator. Does not identify individual vent counts, route, duct size or installed radiator.
IMG_0884 · Locate on drawing ↗Drawing notation: Vents to Radiator
Caption under lower service plan associates vent condition with radiator. Does not identify individual vent counts, route, duct size or installed radiator.
f6-room-607-wall-south-millworkverified-qualitative · observed
lower_plan_service_observation
UnresolvedLower plan contains rectangular crosshatched grille-like fields and oval vent symbols. Graphic repetition is not an installed quantity or exact geometry.
IMG_0884 · Locate on drawing ↗Lower plan contains rectangular crosshatched grille-like fields and oval vent symbols. Graphic repetition is not an installed quantity or exact geometry.
f6-room-607-wall-south-millworkpartial · observed
open_for_bronze_grille_condition
All sliding doors open ... for Bronze grilles [partial]South-wall central drawing annotation; presence of bronze-grille/open condition only. Connecting words and exact leaf allocation unresolved.
IMG_0884 · Locate on drawing ↗Drawing notation: All sliding doors open ... for Bronze grilles [partial]
South-wall central drawing annotation; presence of bronze-grille/open condition only. Connecting words and exact leaf allocation unresolved.