drawing_title
DISTRICT COURT ROOM BALUSTRADESAuthoring eligible: false. Source audit state: verified.
Drawing notation: DISTRICT COURT ROOM BALUSTRADES
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Object: IMG_0899 Room 602 balustrade shop-detail register
Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
Authoring eligible: false. Source audit state: verified.
Drawing notation: DISTRICT COURT ROOM BALUSTRADES
2008 count
Authoring eligible: false. Source audit state: verified.
Drawing notation: ORDER NO. 2008
68 count
Authoring eligible: false. Source audit state: verified.
Drawing notation: DRAWING NO. 68
Authoring eligible: false. Source audit state: verified.
Drawing notation: 1/3/33
Authoring eligible: false. Source audit state: verified-transcription; meaning-of-EPN-unresolved.
Drawing notation: EPN 1/27/33
36 distinct marks
Authoring eligible: false. Source audit state: verified-mark-set; not-an-installed-quantity.
Drawing notation: 1 through 36
Room 602 and Room 612 between-base-faces dimension values are unreadable/obscured. Overall height, complete rail/base sections, exact endpoints, post/baluster spacing, installed quantities, and gate width/swing are unresolved. Several visible dimensions lack defensible endpoints because folds and overlaid sheets cross the linework. The 1–36 shop-part marks are transcribed, but a complete fabrication/joinery map is not verified. IMG_0899 has no world transform and is not registered to W257 or W8. The W257 SEE DETAIL SHEET No. 238 callout is not positively resolved to IMG_0899; Shop Drawing No. 68 is not treated as architectural Sheet 238. No paper-scale or pixel-derived measurements are permitted.
Drawing notation: DISTRICT COURT ROOM BALUSTRADES
Complete photographed field after clockwise rotation to analysis-upright orientation.
1 count
IMG_0899 may augment component identity, white-oak/finish intent, the inward joint-orientation rule, shop part marks, and a few local controls. It must not generate or replace Room 602 physical balustrade geometry.
Drawing notation: DISTRICT COURT ROOM BALUSTRADES
Complete photographed field after clockwise rotation to analysis-upright orientation.
Source-local observation/reference only; no dimensions, approval or world geometry inferred beyond stated evidence.
Drawing notation: [part strips intersect folds and overlapped sheet regions]
Source-local observation/reference only; no dimensions, approval or world geometry inferred beyond stated evidence.
Numeric value unresolved
Same previously prepared upright master strip reviewed sequentially. Label readable; numerical token remains illegible. No derived run from repeated bays or mirrored Room612 length.
Drawing notation: DISTRICT COURT 602 BETWEEN BASE FACES [number obscured]
Same previously prepared upright master strip reviewed sequentially. Label readable; numerical token remains illegible. No derived run from repeated bays or mirrored Room612 length.
Numeric value unresolved
Direct high-resolution plan/title strip verifies label and endpoint class BETWEEN BASE FACES, already established in prior report; numeric room run is still unreadable. The same strip also labels612; no copied length or installed run accepted.
Drawing notation: DISTRICT COURT 602 BETWEEN BASE FACES [dimension numeral illegible]
Direct high-resolution plan/title strip verifies label and endpoint class BETWEEN BASE FACES, already established in prior report; numeric room run is still unreadable. The same strip also labels612; no copied length or installed run accepted.
Source inventory is separate from the floor filters above. Select one drawing to inspect it; no drawing set is preloaded.