Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
f6-court602-img0897-door-detail-registerverified · printed
drawing_title
1" SCALE ELEVATION DOOR BEHIND JUDGES DESK DISTRICT COURTAuthoring eligible: false. Source audit state: verified.
f6-court602-img0897-door-detail-registerverified · printed
drawing_scale_notation
1" SCALE1 paper_in_per_building_ft
Drawing-scale notation only; no pixel calibration or paper scaling is allowed. Authoring eligible: false. Source audit state: verified-notation-only.
f6-court602-img0897-door-detail-registerverified · printed
fabrication_quantity
2 REQUIRED2 count
A drawing-level fabrication quantity. It does not prove two leaves in one opening and does not assign one assembly to Room 602 and another to Room 612. Authoring eligible: false. Source audit state: verified.
f6-court602-img0897-door-detail-registerverified · printed
detail_number
Detail #20Authoring eligible: false. Source audit state: verified.
f6-court602-img0897-door-detail-registerverified · printed
approval_disposition
APPROVED FOR DESIGN ONLYAuthoring eligible: false. Source audit state: verified.
f6-court602-img0897-door-detail-registerverified · printed
approval_date
EPN 10/7/32Authoring eligible: false. Source audit state: verified; initials meaning unresolved.
f6-court602-img0897-door-detail-registerverified · printed
wood_species_and_selection
All Fine grained Plain white Oak.Authoring eligible: false. Source audit state: verified.
f6-court602-img0897-door-detail-registerverified · printed
surface_tooling
Hand tooled with Jack Plane and wire Brushed to match sampleAuthoring eligible: false. Source audit state: verified.
f6-court602-img0897-door-detail-registerverified · printed
exposed_wood_finish
Exposed parts to be stained to match sample for a wax finish.Authoring eligible: false. Source audit state: verified.
f6-court602-img0897-door-detail-registerverified · printed
unexposed_wood_coating
Unexposed parts to be Primed with lead and oil.Authoring eligible: false. Source audit state: verified.
f6-court602-img0897-door-detail-registerverified · printed
overall_elevation_width
6'-5 1/2"77.5 in
Authoring eligible: false. Source audit state: verified; chain-closes.
f6-court602-img0897-door-detail-registerverified · derived
calculated_width_chain_closure
2 1/2 + 12 + 3 1/4 + 3'-6 + 3 1/4 + 12 + 2 1/2 = 6'-5 1/2"77.5 in
Authoring eligible: false. Source audit state: verified arithmetic; not independent geometry.
Calculated from: court602-img0897-left-outer-return, court602-img0897-left-pilaster-width, court602-img0897-left-trim-width, court602-img0897-door-width-correction, court602-img0897-right-trim-width, court602-img0897-right-pilaster-width, court602-img0897-right-outer-return
f6-court602-img0897-door-detail-registerverified · printed
overall_vertical_control
12'-5 5/8"149.625 in
Retained as a sheet-local vertical control only; owning architectural datum and full endpoints are not secure. Authoring eligible: false. Source audit state: verified-reading; upper endpoint is at photograph boundary.
f6-court602-img0897-door-detail-registerunreviewed · printed
intermediate_vertical_control
6'-? 7/8" [partly legible]Authoring eligible: false. Source audit state: explicit-null; middle digit and endpoints unresolved.
f6-court602-img0897-door-detail-registerverified · observed
Physical judge-door geometry gate
FAIL — design-only corrections and incomplete assemblyThe sheet is stamped APPROVED FOR DESIGN ONLY, not approved for construction. Printed 7'-7 5/8" and correction-marked 8'-2" door heights conflict without a later accepted revision. The correction-marked 3'-6" Door value is preserved but is not promoted to accepted construction width. Leaf count, swing, thickness, panel layout and every hardware item are unresolved. Complete frame, trim, cap, base, transom and flute profiles are not dimensioned. Several vertical dimension strings have incomplete readings or insecure endpoints. The drawing-level quantity 2 is not an installed Room 602 quantity and is not evidence for a Room 612 copy. No paper-scale or pixel-derived measurements are permitted.
f6-court602-img0897-door-detail-registerverified · derived
Analytical local horizontal dimension-chain study permitted
Permitted; not a door, frame or accepted construction width1 count
Only the seven closed horizontal dimension segments may be rendered as independent local witnesses. The design-only approval, vertical conflict, profiles, leaf construction, hardware and placement remain blocked.
Calculated from: court602-img0897-width-chain-closure
f6-court602-img0897-door-detail-registerRed check aligns with design-only stamp line; neither dimensions nor construction approval established. · observed-stamp-and-review-mark
approval_scope
APPROVED FOR DESIGN ONLY [red check]Source-local observation/reference only; no dimensions, approval or world geometry inferred beyond stated evidence.
IMG_0897 · Locate on drawing ↗Drawing notation: APPROVED FOR DESIGN ONLY [red check]
Source-local observation/reference only; no dimensions, approval or world geometry inferred beyond stated evidence.
f6-court602-img0897-door-detail-registerillegible · printed
intermediate_vertical_control_followup
6'-? 7/8" [middle digit still insecure]Numeric value unresolved
Same photographed dimension locus as court602-img0897-intermediate-vertical-unresolved. Master detail retains insecure middle digit and upper endpoint; no numeric resolution.
IMG_0897 · Locate on drawing ↗Drawing notation: 6'-? 7/8" [middle digit still insecure]
Same photographed dimension locus as court602-img0897-intermediate-vertical-unresolved. Master detail retains insecure middle digit and upper endpoint; no numeric resolution.