Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
f5-stair-d-w224-img1261-diagnostic-placementunreviewed · derived
Conditional diagnostic origin X
34.5 ft34.5 ft
Display candidate only. The nearby provisional fifth-floor trace is corroborative but not an accepted metric transform.
IMG_1261 · sheet-W224 · Locate on drawing ↗Drawing notation: W224 / DETAIL OF STAIR D AND FAN ROOM / 3RD, 4TH, 5TH & 6TH FLOOR PLAN / 1'-4" (4'-4" ON 6TH FL.) / 6'-1 1/4" ON 6TH FL. / 9'-0" TO CL OF COL. 82
Alternate W224 photograph. Printed controls and the sixth-floor landing exception are corroborated; every candidate building transform remains conditional on explicit column and wall-face offsets.
Calculated from: img1261-w224-diagnostic-origin-x, img1261-w224-ordinary-plan-applicability
f5-stair-d-w224-img1261-diagnostic-placementverified · derived
Conditional diagnostic origin Y
55.5 ft55.5 ft
The floor datum is accepted; the individual equal-riser elevations remain inferred.
IMG_1261 · sheet-W224 · Locate on drawing ↗Drawing notation: W224 / DETAIL OF STAIR D AND FAN ROOM / 3RD, 4TH, 5TH & 6TH FLOOR PLAN / 1'-4" (4'-4" ON 6TH FL.) / 6'-1 1/4" ON 6TH FL. / 9'-0" TO CL OF COL. 82
Alternate W224 photograph. Printed controls and the sixth-floor landing exception are corroborated; every candidate building transform remains conditional on explicit column and wall-face offsets.
Calculated from: env-sixth-F5-level, frame-first-floor-finish
f5-stair-d-w224-img1261-diagnostic-placementunreviewed · derived
Conditional diagnostic origin Z
39 ft39 ft
Display candidate only. Arithmetic precision does not establish the unresolved column and wall-face corrections.
IMG_1261 · sheet-W224 · Locate on drawing ↗Drawing notation: W224 / DETAIL OF STAIR D AND FAN ROOM / 3RD, 4TH, 5TH & 6TH FLOOR PLAN / 1'-4" (4'-4" ON 6TH FL.) / 6'-1 1/4" ON 6TH FL. / 9'-0" TO CL OF COL. 82
Alternate W224 photograph. Printed controls and the sixth-floor landing exception are corroborated; every candidate building transform remains conditional on explicit column and wall-face offsets.
Calculated from: img1261-w224-diagnostic-origin-z, img1261-w224-ordinary-plan-applicability
f5-stair-d-w224-img1261-diagnostic-placementverified · traced
Fifth-floor provisional trace coordination
UnresolvedThe provisional fifth-floor trace spans approximately X 34.578–49.937 and Z 37.674–46.531 feet, close to but not coincident with the W224 zero-offset candidate X 34.5–50.3333 and Z 39–47 feet. The residual is retained for review.
IMG_1261 · sheet-W224 · Locate on drawing ↗Drawing notation: W224 / DETAIL OF STAIR D AND FAN ROOM / 3RD, 4TH, 5TH & 6TH FLOOR PLAN / 1'-4" (4'-4" ON 6TH FL.) / 6'-1 1/4" ON 6TH FL. / 9'-0" TO CL OF COL. 82
Alternate W224 photograph. Printed controls and the sixth-floor landing exception are corroborated; every candidate building transform remains conditional on explicit column and wall-face offsets.
Calculated from: f5-stair-d-footprint-trace, img1261-w224-f5-diagnostic-origin-x, img1261-w224-f5-diagnostic-origin-z
f5-stair-d-w224-img1261-diagnostic-placementverified · observed
Accepted fifth-floor Stair D building transform
UnresolvedWithheld until the column/wall offsets and the provisional fifth-floor trace are reconciled.
IMG_1261 · sheet-W224 · Locate on drawing ↗Drawing notation: W224 / DETAIL OF STAIR D AND FAN ROOM / 3RD, 4TH, 5TH & 6TH FLOOR PLAN / 1'-4" (4'-4" ON 6TH FL.) / 6'-1 1/4" ON 6TH FL. / 9'-0" TO CL OF COL. 82
Alternate W224 photograph. Printed controls and the sixth-floor landing exception are corroborated; every candidate building transform remains conditional on explicit column and wall-face offsets.