Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
f4-stair-d-w6-tight-locator-checkverified · printed
printed_stair_identity
STAIR DRetain the exact world transform and slab-opening correspondence as null. Continue only as an analytical diagnostic. No trace fitting, source-point snapping, slab cut or physical stair placement is authorized by this evidence.
f4-stair-d-w6-tight-locator-checkunreviewed · traced
left_visible_stair_partition_trace_source_x
2345 raw-pixel2345 px
Visible line pick; rough, finish, and inner-boundary equivalence unresolved.
f4-stair-d-w6-tight-locator-checkunreviewed · traced
right_visible_stair_partition_trace_source_x
2549 raw-pixel2549 px
Visible line pick; rough, finish, and inner-boundary equivalence unresolved.
f4-stair-d-w6-tight-locator-checkunreviewed · traced
upper_visible_stair_partition_trace_source_y
1889 raw-pixel1889 px
Not classified as an upper slab-opening edge.
f4-stair-d-w6-tight-locator-checkunreviewed · traced
lower_visible_stair_partition_trace_source_y
1999 raw-pixel1999 px
Not classified as a lower slab-opening edge.
f4-stair-d-w6-tight-locator-checkunreviewed · derived
diagnostic_registered_bbox_min_x
33.226268030081414 ft33.226268 ft
Photographic registration result, not an accepted wall location.
f4-stair-d-w6-tight-locator-checkunreviewed · derived
diagnostic_registered_bbox_max_x
49.16746271807047 ft49.167463 ft
Retain the exact world transform and slab-opening correspondence as null. Continue only as an analytical diagnostic. No trace fitting, source-point snapping, slab cut or physical stair placement is authorized by this evidence.
f4-stair-d-w6-tight-locator-checkunreviewed · derived
diagnostic_registered_bbox_min_z
37.120437654228425 ft37.120438 ft
Retain the exact world transform and slab-opening correspondence as null. Continue only as an analytical diagnostic. No trace fitting, source-point snapping, slab cut or physical stair placement is authorized by this evidence.
f4-stair-d-w6-tight-locator-checkunreviewed · derived
diagnostic_registered_bbox_max_z
45.90008722329193 ft45.900087 ft
Retain the exact world transform and slab-opening correspondence as null. Continue only as an analytical diagnostic. No trace fitting, source-point snapping, slab cut or physical stair placement is authorized by this evidence.
f4-stair-d-w6-tight-locator-checkunreviewed · derived
diagnostic_registered_bbox_x_span
15.941194687989054 ft15.941195 ft
Close to but not a source-proof of W224's printed 15-foot-10-inch inner span; W-6 line classes differ or remain unknown.
IMG_1212 · sheet-W6 · Locate on drawing ↗Close to but not a source-proof of W224's printed 15-foot-10-inch inner span; W-6 line classes differ or remain unknown. Diagnostic source region; not a physical stair face.
f4-stair-d-w6-tight-locator-checkunreviewed · derived
diagnostic_registered_bbox_z_span
8.779649569063508 ft8.77965 ft
Do not equate with W224's printed 8-foot inner width.
f4-stair-d-w6-tight-locator-checkunreviewed · derived
diagnostic_w6_minus_zero_offset_w224_min_x
-1.273731969918586 ft-1.273732 ft
Comparison of potentially different line classes; cannot solve delta82X or epsilonX.
f4-stair-d-w6-tight-locator-checkunreviewed · derived
diagnostic_w6_minus_zero_offset_w224_min_z
-1.8795623457715749 ft-1.879562 ft
Comparison of potentially different line classes; cannot solve delta82Z or epsilonZ.