Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
f3-stair-dunreviewed · traced
Boundary vertex 1 · west
34.382 ft (trace)34.382 ft · estimated uncertainty ±2.5 ft
Calculated from: f3-stair-d-footprint-trace
f3-stair-dunreviewed · traced
Boundary vertex 1 · north
37.99 ft (trace)37.99 ft · estimated uncertainty ±2.5 ft
Calculated from: f3-stair-d-footprint-trace
f3-stair-dunreviewed · traced
Boundary vertex 2 · west
50.501 ft (trace)50.501 ft · estimated uncertainty ±2.5 ft
Calculated from: f3-stair-d-footprint-trace
f3-stair-dunreviewed · traced
Boundary vertex 2 · north
38.052 ft (trace)38.052 ft · estimated uncertainty ±2.5 ft
Calculated from: f3-stair-d-footprint-trace
f3-stair-dunreviewed · traced
Boundary vertex 3 · west
50.678 ft (trace)50.678 ft · estimated uncertainty ±2.5 ft
Calculated from: f3-stair-d-footprint-trace
f3-stair-dunreviewed · traced
Boundary vertex 3 · north
46.631 ft (trace)46.631 ft · estimated uncertainty ±2.5 ft
Calculated from: f3-stair-d-footprint-trace
f3-stair-dunreviewed · traced
Boundary vertex 4 · west
34.277 ft (trace)34.277 ft · estimated uncertainty ±2.5 ft
Calculated from: f3-stair-d-footprint-trace
f3-stair-dunreviewed · traced
Boundary vertex 4 · north
46.71 ft (trace)46.71 ft · estimated uncertainty ±2.5 ft
Calculated from: f3-stair-d-footprint-trace
f3-stair-dverified · printed
marked_up_flight_riser_count
UP 20R20 count
f3-stair-dverified · printed
marked_down_flight_riser_count
DOWN 20R20 count
f3-stair-dverified · printed
source_stair_identity
STAIR DIMG_1211 · Locate on drawing ↗Drawing notation: STAIR D
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Existing canonical f3-stair-d corresponds to this explicitly labeled assembly, not Stair B.
f3-stair-dverified · observed
W224_type_correspondence
Upper strip UP 20R to page-left; lower strip DOWN 20R; entry on page-rightMatches plan handedness and door side. Does not determine translation or wall thickness.
IMG_1211 · Locate on drawing ↗Drawing notation: UP 20R / DOWN 20R
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference.
f3-stair-dverified · observed
upright_plan_world_orientation
Page-right = Broadway / west; page-down = Main / northIMG_1211 · Locate on drawing ↗Drawing notation: MADISON ST. / BROADWAY / MAIN ST. / SIXTH ST.
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Compass/street key read in the single overview; consistent with existing canonical axes.
f3-stair-dverified · derived
local_u_world_x_coefficient
11 ratio
Axis direction only; no scale fitting or insertion translation.
IMG_1211 · Locate on drawing ↗Drawing notation: STAIR D / UP 20R / DOWN 20R
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference.
Calculated from: f3-stair-d-placement-type-correspondence, f3-stair-d-placement-compass
f3-stair-dverified · derived
local_u_world_z_coefficient
00 ratio
Axis direction only; no scale fitting or insertion translation.
IMG_1211 · Locate on drawing ↗Drawing notation: STAIR D / UP 20R / DOWN 20R
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference.
Calculated from: f3-stair-d-placement-type-correspondence, f3-stair-d-placement-compass
f3-stair-dverified · derived
local_v_world_x_coefficient
00 ratio
Axis direction only; no scale fitting or insertion translation.
IMG_1211 · Locate on drawing ↗Drawing notation: STAIR D / UP 20R / DOWN 20R
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference.
Calculated from: f3-stair-d-placement-type-correspondence, f3-stair-d-placement-compass
f3-stair-dverified · derived
local_v_world_z_coefficient
11 ratio
Axis direction only; no scale fitting or insertion translation.
IMG_1211 · Locate on drawing ↗Drawing notation: STAIR D / UP 20R / DOWN 20R
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference.
Calculated from: f3-stair-d-placement-type-correspondence, f3-stair-d-placement-compass
f3-stair-dverified · derived
local_h_world_y_coefficient
11 ratio
Axis direction only; no scale fitting or insertion translation.
IMG_1211 · Locate on drawing ↗Drawing notation: STAIR D / UP 20R / DOWN 20R
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference.
Calculated from: f3-stair-d-placement-type-correspondence, f3-stair-d-placement-compass
f3-stair-dverified · derived
UV_to_XZ_determinant
1; no reflection1 ratio
IMG_1211 · Locate on drawing ↗Drawing notation: STAIR D
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference.
Calculated from: f3-stair-d-placement-u-x, f3-stair-d-placement-u-z, f3-stair-d-placement-v-x, f3-stair-d-placement-v-z
f3-stair-dverified · derived
local_UV_to_canonical_XZ_rotation
0°0 degree
IMG_1211 · Locate on drawing ↗Drawing notation: STAIR D
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference.
Calculated from: f3-stair-d-placement-u-x, f3-stair-d-placement-v-z
f3-stair-dverified · printed
third_floor_original_finish_elevation
FIN. FL. ELEV. 125.75125.75 ft
Drawing datum, not a claim about sea-level datum. No local stair-floor step is read.
IMG_1211 · Locate on drawing ↗Drawing notation: THIRD FLOOR PLAN / FIN. FL. ELEV.125.75
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Read at the plan title in the overview. Corroborates frame-third-floor-schedule-finish and ms-frame-third-floor-schedule-finish-printed.
f3-stair-dverified · derived
third_floor_finish_above_first_floor_zero
125.75 − 93.25 = 32.5 ft32.5 ft
IMG_1211 · Locate on drawing ↗Drawing notation: FIN. FL. ELEV.125.75
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference.
Calculated from: f3-stair-d-placement-third-floor-datum, frame-first-floor-finish
f3-stair-dverified · printed
W224_right_hand_column_axis_marks
℄ OF COL. (82) (68)f3-stair-dverified · printed
printed_horizontal_column_axis_to_right_wall_reference
1′4″1.333333 ft
The numeral is secure; endpoint semantics are a separate unresolved property.
IMG_1114 · sheet-W224 · Locate on drawing ↗Drawing notation: 1′4″
Dimension lies between the C82/C68 axis and right stair-wall reference. Parenthetical sixth-floor variant is excluded. Exact inner/outer/finish-face endpoint still needs confirmation before deriving insertion coordinate.
f3-stair-dverified · printed
printed_lower_wall_reference_to_column82_distance
9′0″ TO ℄ COL 829 ft
Printed scalar only; do not subtract from C82 to obtain a finished inner corner until the witness endpoint is identified.
IMG_1114 · sheet-W224 · Locate on drawing ↗Drawing notation: 9′0″ TO ℄ COL 82
The ordinate arrow meets the lower hatched wall area. It is not securely established whether the referenced line is the finish face, structure face or another wall datum.
f3-stair-dunreviewed · observed
exact_horizontal_offset_wall_face
UnresolvedDetermine whether the 1′4″ witness terminates at the finished inner boundary used by the prototype.
IMG_1211 · Locate on drawing ↗Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Determine whether the 1′4″ witness terminates at the finished inner boundary used by the prototype.
f3-stair-dunreviewed · observed
exact_north_offset_wall_face
UnresolvedDetermine which lower wall line the 9′0″ ordinate references, including any wall/finish thickness.
IMG_1211 · Locate on drawing ↗Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Determine which lower wall line the 9′0″ ordinate references, including any wall/finish thickness.
f3-stair-dunreviewed · observed
accepted_type_origin_world_x
UnresolvedNumeric value unresolved
Requires verified interior support station and exact wall-face endpoint.
IMG_1211 · Locate on drawing ↗Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Requires verified interior support station and exact wall-face endpoint.
f3-stair-dunreviewed · observed
accepted_type_origin_world_z
UnresolvedNumeric value unresolved
Requires verified C82 station and exact 9′0″ wall-reference endpoint.
IMG_1211 · Locate on drawing ↗Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Requires verified C82 station and exact 9′0″ wall-reference endpoint.
f3-stair-dunreviewed · observed
accepted_door_jamb_world_station
UnresolvedNumeric value unresolved
Door is a handedness locator; precise jamb/host offsets not extracted.
IMG_1211 · Locate on drawing ↗Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Door is a handedness locator; precise jamb/host offsets not extracted.
f3-stair-dunreviewed · observed
north_offset_endpoint_observation
9′0″ TO ℄ COL82 meets the lower hatched-wall referencef3-stair-dunreviewed · observed
accepted_9ft_endpoint_face_category
UnresolvedLower-wall finish/core/other reference remains unresolved.
f3-stair-dunreviewed · observed
signed_inner_type_boundary_offset_from_horizontal_witness
UnresolvedNumeric value unresolved
epsilonX = type right inner boundary X minus W224 1′4″ endpoint X; null is not zero.
f3-stair-dunreviewed · observed
signed_inner_type_boundary_offset_from_north_witness
UnresolvedNumeric value unresolved
epsilonZ = type lower inner boundary Z minus W224 9′0″ endpoint Z; null is not zero.
f3-stair-dunreviewed · observed
accepted_type_origin_world_x
UnresolvedNumeric value unresolved
Interior-column control delta and wall-face correction remain unresolved.
f3-stair-dunreviewed · observed
accepted_type_origin_world_z
UnresolvedNumeric value unresolved
Interior-column control delta and wall-face correction remain unresolved.