Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
f1-public-lobby-architectural-envelopeunreviewed · printed
printed_ceiling_height
18'-3"18.25 ft
The re-audit attributes this reading to IMG_1204 in the W3/first-floor-plan family. The image was not reopened for this package. Authoring eligibility: none-until-conflict-resolved. Report transcription; verify the cited drawing before promoting physical geometry. Review correction review-correction-20261013h-lobby-height-report-reading-18-3: Verified same-image raw-upright master crop resolves the same PUBLIC LOBBY ceiling glyph as9 rather than3; no different revision/station is selected.
IMG_1204 · sheet-W3 · View drawing ↗Drawing notation: Public Lobby — ceiling height 18'-3"
Existing text re-audit only; image not reopened. First-floor public-lobby plan, reported 18'-3" ceiling-height reading and repeated 14'/15' structural dimensions
Conflicting readings: lobby-height-existing-package-reading-18-9
f1-public-lobby-architectural-envelopedisputed · printed
printed_ceiling_height
18'-9"18.75 ft
Reused from first-floor-topology.json, where the printed W3 text was independently verified. It does not prove a uniform height in every recess. Authoring eligibility: none-until-conflict-resolved. Report transcription; verify the cited drawing before promoting physical geometry.
Conflicting readings: lobby-height-report-reading-18-3
f1-public-lobby-architectural-envelopeunreviewed · printed
repeated_structural_bay_dimension
14'-0"14 ft
One of the repeated structural dimensions reported on the first-floor public-lobby plan; no count or exact station assignment is asserted. Authoring eligibility: rhythm-reference-only. Report transcription; verify the cited drawing before promoting physical geometry.
IMG_1204 · sheet-W3 · View drawing ↗Drawing notation: 14'-0"
Existing text re-audit only; image not reopened. First-floor public-lobby plan, reported 18'-3" ceiling-height reading and repeated 14'/15' structural dimensions
f1-public-lobby-architectural-envelopeunreviewed · printed
repeated_structural_bay_dimension
15'-0"15 ft
One of the repeated structural dimensions reported on the first-floor public-lobby plan; no count or exact station assignment is asserted. Authoring eligibility: rhythm-reference-only. Report transcription; verify the cited drawing before promoting physical geometry.
IMG_1204 · sheet-W3 · View drawing ↗Drawing notation: 15'-0"
Existing text re-audit only; image not reopened. First-floor public-lobby plan, reported 18'-3" ceiling-height reading and repeated 14'/15' structural dimensions