Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
f1-main-foyer-public-lobby-screen-assemblyverified · observed
paired-door count
three separate paired swing symbols in BAY V, BAY U, BAY T3 pair
verified-for-count-and-row-only. Source-side classification does not establish a physical face or finished jamb station.
f1-main-foyer-public-lobby-screen-assemblyunreviewed · derived
distance between classified physical room-facing faces
unresolvedNumeric value unresolved
unresolved; parent face stations null. Source-side classification does not establish a physical face or finished jamb station.
Calculated from: audit-w3-main-screen-lobby-face-station, audit-w3-main-screen-foyer-face-station
f1-main-foyer-public-lobby-screen-assemblyunreviewed · inferred
lobby-facing finished face world Z
UnresolvedNumeric value unresolved
unresolved: no classified continuous finished face. A composed screen cannot be extruded as one opaque wall.
IMG_1202 · sheet-W3 · Locate on drawing ↗unresolved: no classified continuous finished face; The candidate is a composed transparent screen rather than one continuous opaque wall; no classified front/back face, thickness, segment footprints, finished jamb pairs, threshold elevation, or finished top is accepted in canonical coordinates.
f1-main-foyer-public-lobby-screen-assemblyunreviewed · inferred
foyer-facing finished face world Z
UnresolvedNumeric value unresolved
unresolved: no classified continuous finished face. A composed screen cannot be extruded as one opaque wall.
IMG_1202 · sheet-W3 · Locate on drawing ↗unresolved: no classified continuous finished face; The candidate is a composed transparent screen rather than one continuous opaque wall; no classified front/back face, thickness, segment footprints, finished jamb pairs, threshold elevation, or finished top is accepted in canonical coordinates.
f1-main-foyer-public-lobby-screen-assemblyunreviewed · inferred
face-to-face depth by segment
UnresolvedNumeric value unresolved
unresolved. A composed screen cannot be extruded as one opaque wall.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY U; HALF ELEVATION OF BAY U; BAYS T & V SIMILAR
unresolved; The candidate is a composed transparent screen rather than one continuous opaque wall; no classified front/back face, thickness, segment footprints, finished jamb pairs, threshold elevation, or finished top is accepted in canonical coordinates.
f1-main-foyer-public-lobby-screen-assemblyunreviewed · inferred
each solid pier/return XZ footprint and join
UnresolvedNumeric value unresolved
unresolved. A composed screen cannot be extruded as one opaque wall.
IMG_1202 · sheet-W3 · Locate on drawing ↗unresolved; The candidate is a composed transparent screen rather than one continuous opaque wall; no classified front/back face, thickness, segment footprints, finished jamb pairs, threshold elevation, or finished top is accepted in canonical coordinates.
f1-main-foyer-public-lobby-screen-assemblyunreviewed · inferred
finished threshold or screen bottom local Y
UnresolvedNumeric value unresolved
unresolved; floor datum alone is not threshold elevation. A composed screen cannot be extruded as one opaque wall.
IMG_1099 · sheet-W218 · Locate on drawing ↗Drawing notation: PLAN OF DOORS BETWEEN FOYER & LOBBY
unresolved; floor datum alone is not threshold elevation; The candidate is a composed transparent screen rather than one continuous opaque wall; no classified front/back face, thickness, segment footprints, finished jamb pairs, threshold elevation, or finished top is accepted in canonical coordinates.
f1-main-foyer-public-lobby-screen-assemblyunreviewed · inferred
finished screen/pier top local Y
UnresolvedNumeric value unresolved
unresolved; neither room ceiling nor next-storey datum assigns screen top. A composed screen cannot be extruded as one opaque wall.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY U; HALF ELEVATION OF BAY U; BAYS T & V SIMILAR
unresolved; neither room ceiling nor next-storey datum assigns screen top; The candidate is a composed transparent screen rather than one continuous opaque wall; no classified front/back face, thickness, segment footprints, finished jamb pairs, threshold elevation, or finished top is accepted in canonical coordinates.
f1-main-foyer-public-lobby-screen-assemblyverified · printed
Bay U elevation pattern applies to T and V as similar types
BAYS T & V SIMILAR1 count
supported for typological repetition only, not exact per-bay dimensions. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-main-foyer-public-lobby-screen-assemblyverified · printed
section title names three bays
SECTION THRU BAYS U T & V3 count
supported for section applicability, not a canonical vertical interval. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-main-foyer-public-lobby-screen-assemblyverified · observed
fixed glazed field above the paired door-head ornament
FIXED ... CLEAR PLATE GLASS; METAL & GLASS1 count
supported as Bay U construction; precise glazing limits unresolved. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-main-foyer-public-lobby-screen-assemblyverified · observed
fixed glazed upper field on foyer-facing side
FIXED CLEAR PLATE GLASS1 count
supported for construction class; top/bottom limits unresolved. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-main-foyer-public-lobby-screen-assemblyverified · observed
decorative metal band between paired door field and upper glazing
REPEAT CAST METAL ORNAMENT AS SHOWN1 count
supported for distinct band; thickness and elevation unresolved. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-main-foyer-public-lobby-screen-assemblyverified · observed
fixed glazed jamb beside paired leaves
FIXED JAMB1 count
supported for component identity, not face stations. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-main-foyer-public-lobby-screen-assemblyverified · printed
threshold material at screen passage
METAL THRESHOLD1 count
supported for material; top elevation and profile unresolved. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-main-foyer-public-lobby-screen-assemblyunreviewed · observed
finished screen/threshold bottom local Y
UnresolvedNumeric value unresolved
unresolved: floor line and threshold are shown, but threshold top/bottom is not tied by a checked elevation to W3's finish datum. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
IMG_1099 · sheet-W218 · Locate on drawing ↗Drawing notation: SECTION G-G; METAL THRESHOLD
unresolved: floor line and threshold are shown, but threshold top/bottom is not tied by a checked elevation to W3's finish datum
f1-main-foyer-public-lobby-screen-assemblyunreviewed · observed
finished screen, pier and head top local Y by segment
UnresolvedNumeric value unresolved
unresolved: screen meets overhead plaster/beam zone, with no accepted finished top height for every segment. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-main-foyer-public-lobby-screen-assemblyunreviewed · observed
solid pier/return finished depth at Bay U
UnresolvedNumeric value unresolved
unresolved: drawn depth layers cannot be equated to one continuous two-face wall depth. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-main-foyer-public-lobby-screen-assemblyunreviewed · observed
foyer-to-lobby finished face depth by door/screen segment
UnresolvedNumeric value unresolved
unresolved: horizontal dimension chains run along the screen; transverse arrows do not identify both finished room faces for all segments. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
IMG_1099 · sheet-W218 · Locate on drawing ↗Drawing notation: PLAN OF DOORS BETWEEN FOYER & LOBBY
unresolved: horizontal dimension chains run along the screen; transverse arrows do not identify both finished room faces for all segments