Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
enveloperoof1014u-img1254-profile-groupverified · printed
profile_dd_workroom_wood_wainscot_condition
LINE OF WOOD WAINSCOT IN P.O. WORK ROOMSource-local witness only; no accepted geometry, installed quantity or governing issue. D–D interior finish condition for post-office work room only.
IMG_1254 · W-211 · Locate on drawing ↗Drawing notation: LINE OF WOOD WAINSCOT IN P.O. WORK ROOM
Source-local witness only; no accepted geometry, installed quantity or governing issue. D–D interior finish condition for post-office work room only.
enveloperoof1014u-img1254-profile-groupverified · printed
profile_dd_wood_mould
WOOD MOULDSource-local witness only; no accepted geometry, installed quantity or governing issue. D–D mould callout at top of adjacent wood finish.
IMG_1254 · W-211 · Locate on drawing ↗Drawing notation: WOOD MOULD
Source-local witness only; no accepted geometry, installed quantity or governing issue. D–D mould callout at top of adjacent wood finish.
enveloperoof1014u-img1254-profile-groupverified · printed
profile_dd_marble_wainscot_plaster_condition
LINE OF PLASTER IN ROOMS WHERE MARBLE WAINSCOT OCCURSSource-local witness only; no accepted geometry, installed quantity or governing issue. Conditional marble-wainscot interior finish face; thickness not established.
IMG_1254 · W-211 · Locate on drawing ↗Drawing notation: LINE OF PLASTER IN ROOMS WHERE MARBLE WAINSCOT OCCURS
Source-local witness only; no accepted geometry, installed quantity or governing issue. Conditional marble-wainscot interior finish face; thickness not established.
enveloperoof1014u-img1254-profile-groupverified · printed
profiles_inward_swing_reversal_requirement
NOTE THESE SECTIONS ARE SHOWN FOR OUT SWING SASH FOR IN SWING SASH USE THE SAME SECTIONS BUT JUST REVERSEDSource-local witness only; no accepted geometry, installed quantity or governing issue. Vertical note beside C–C/B–B. Directional rule preserved; not authorization to mirror all installed geometry.
IMG_1254 · W-211 · Locate on drawing ↗Drawing notation: NOTE THESE SECTIONS ARE SHOWN FOR OUT SWING SASH FOR IN SWING SASH USE THE SAME SECTIONS BUT JUST REVERSED
Source-local witness only; no accepted geometry, installed quantity or governing issue. Vertical note beside C–C/B–B. Directional rule preserved; not authorization to mirror all installed geometry.
enveloperoof1014u-img1254-profile-groupverified · printed
profile_bb_toilet_screen_top_alignment
LINE TOP OF FRAMES OF OBSCURE GLASS SCREENS IN TOILET ROOMS WITH THIS MEMBERSource-local witness only; no accepted geometry, installed quantity or governing issue. B–B local screen/frame alignment requirement only.
IMG_1254 · W-211 · Locate on drawing ↗Drawing notation: LINE TOP OF FRAMES OF OBSCURE GLASS SCREENS IN TOILET ROOMS WITH THIS MEMBER
Source-local witness only; no accepted geometry, installed quantity or governing issue. B–B local screen/frame alignment requirement only.
enveloperoof1014u-img1254-profile-groupverified · printed
profile_caulking_specification_reference
REFER TO SPECIFICATIONS PARAGRAPH No 277 FOR CAULKING277 paragraph-number
Source-local witness only; no accepted geometry, installed quantity or governing issue. Separate W211 witness of specification paragraph; no specification content transferred.
IMG_1254 · W-211 · Locate on drawing ↗Drawing notation: REFER TO SPECIFICATIONS PARAGRAPH No 277 FOR CAULKING
Source-local witness only; no accepted geometry, installed quantity or governing issue. Separate W211 witness of specification paragraph; no specification content transferred.