Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
elevator-w229-w231-to-w3-registration-gateverified · observed
Physical elevator placement gate
FAIL — all three physical transforms withheldW229 and W230 retain defensible unit-scale symbolic column frames. W229 establishes the west outside Elevator 1 enclosure face at world X = -65.020833 ft and the 10-foot clear hatch's south/north edges at world Z = 46/56 ft, but its world-X hatch edges remain unresolved. W230 establishes the east outside Elevator 2 enclosure face at X = 65.020833 ft and its 7-foot clear hatch's east/west edges at X = 66.083333/73.083333 ft, but its world-Z hatch edges remain unresolved. Neither detail supplies a complete bounded hatch or shaft. W231 has no exact non-collinear frame, and W3's elevator polygons remain provisional traces with unknown boundary classes. Therefore every physical transform remains null.
elevator-w229-w231-to-w3-registration-gateverified · observed
Accepted symbolic detail-column frames
2 of 3; W229 and W230 only2 count
These unit-scale frames apply only to explicitly dimensioned coordinates tied to named columns; they do not place shaft, hatch, cab, door or landing faces.
elevator-w229-w231-to-w3-registration-gateverified · observed
Accepted physical elevator transforms
00 count
No physical transform is accepted for Elevator 1, 2 or 3.
elevator-w229-w231-to-w3-registration-gateunreviewed · derived
Inherited W3 registration RMS diagnostic
0.8275 ft diagnostic0.8275 ft
These checks assess the provisional W3 sheet registration, not correspondence between elevator detail faces and W3 trace faces.
elevator-w229-w231-to-w3-registration-gateunreviewed · derived
Inherited W3 registration maximum diagnostic residual
0.9845 ft diagnostic0.9845 ft
These checks assess the provisional W3 sheet registration, not correspondence between elevator detail faces and W3 trace faces.
elevator-w229-w231-to-w3-registration-gateverified · observed
Elevator 1 symbolic detail-column frame
Accepted for explicitly dimensioned local coordinates only1 count
Dimensioned coordinates explicitly tied to named W229 column axes only.
elevator-w229-w231-to-w3-registration-gateverified · observed
Elevator 1 accepted physical transform
Nonefail-physical-placement-hatch-x-edges-unresolved
elevator-w229-w231-to-w3-registration-gateverified · observed
Elevator 2 symbolic detail-column frame
Accepted for explicitly dimensioned local coordinates only1 count
Dimensioned coordinates explicitly tied to named W230 column axes only.
elevator-w229-w231-to-w3-registration-gateverified · observed
Elevator 2 accepted physical transform
Nonefail-physical-placement-hatch-z-edges-unresolved
elevator-w229-w231-to-w3-registration-gateverified · observed
Elevator 3 symbolic detail-column frame
Unresolvedfail-no-dimensioned-non-collinear-frame
elevator-w229-w231-to-w3-registration-gateverified · observed
Elevator 3 accepted physical transform
Nonefail-no-dimensioned-non-collinear-frame