Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
door-img1126-later-head-jambverified · printed
marble_applicability_exception
MARBLE OCCURS ELEV. #1 AT BASMT.Leader beside later head/jamb: an explicit material applicability statement, not a blanket marble assignment to all elevator enclosures.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: MARBLE OCCURS ELEV. #1 AT BASMT.
Leader beside later head/jamb: an explicit material applicability statement, not a blanket marble assignment to all elevator enclosures.
door-img1126-later-head-jambverified · printed
head_plate_and_buck_material
NICK. STEEL PLATE & BUCKPreserves printed abbreviation NICK.; no alloy, finish process, gauge or installed floor range inferred.
door-img1126-later-head-jambunresolved · printed
head_plate_thickness
[fraction before NICK. STEEL PLATE & BUCK unresolved]Numeric value unresolved
Fine fraction remains unreadable in existing master crop. Preserve null rather than accepting a nominal plate gauge.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: [fraction before NICK. STEEL PLATE & BUCK unresolved]
Fine fraction remains unreadable in existing master crop. Preserve null rather than accepting a nominal plate gauge.
door-img1126-later-head-jambverified · printed
later_head_nickel_steel_plate_thickness_resolution
3/16″ STEEL NICKEL PLATE & BUCK0.1875 in
Fraction belongs to later head plate-and-buck leader; original photographic layer only. Does not establish alloy, nickel process, installed thickness or applicability beyond the separate printed caption.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: 3/16″ STEEL NICKEL PLATE & BUCK
Fraction belongs to later head plate-and-buck leader; original photographic layer only. Does not establish alloy, nickel process, installed thickness or applicability beyond the separate printed caption.
Calculated from: door-20261012p-1126-m007
door-img1126-later-head-jambverified · printed
later_head_fascia_plate_gauge
14 GA. STEEL FACIA PLATE14 gauge
Printed later-head fascia stock gauge, independent of plate-and-buck thickness and sixth-floor variant.
door-img1126-later-head-jambverified · printed
later_head_fascia_plate_material
14 GA. STEEL FACIA PLATEPrinted steel fascia plate, preserving FACIA spelling; no gauge-to-inch conversion or alloy inferred.
door-img1126-later-head-jambverified · printed
later_head_cover_plate_gauge
14 GA. REMOVABLE OR HINGED COVER PLATE14 gauge
Cover gauge is distinct from steel-nickel buck and fascia stock.
door-img1126-later-head-jambverified · printed
later_head_cover_access_relationship
14 GA. REMOVABLE OR HINGED COVER PLATEPrinted alternatives removable or hinged; does not establish hinge or fixing sizes.
door-img1126-later-head-jambverified · printed
later_jamb_sill_material
ANTI-SLIP BRONZE SILLPrinted bronze sill in later jamb view; small Elevator3 first-floor exception retained separately.
door-img1126-later-head-jambverified · printed
later_sill_material
ANTI-SLIP BRONZE SILLPrinted common sill section material/surface. Separate source property from first/sixth-floor sill.
door-img1126-later-head-jambverified · printed
later_sill_horizontal_witness
11½″11.5 in
Sill-section horizontal witness across depicted bronze sill assembly; end classes and installed threshold span unresolved, not entrance clear width.
IMG_1129 · W-229 · Locate on drawing ↗Drawing notation: 11½″
Sill-section horizontal witness across depicted bronze sill assembly; end classes and installed threshold span unresolved, not entrance clear width.
door-img1126-later-head-jambverified · printed
later_sill_anchor_plate_thickness
3/16″ BENT UP ANGLES ANCHORED TO STEEL I BEAM IN AN APPROVED MANNER0.1875 in
Printed thickness prefix of bent-up angle anchors; leg dimensions, profile and attachment method not established.
IMG_1129 · W-229 · Locate on drawing ↗Drawing notation: 3/16″ BENT UP ANGLES ANCHORED TO STEEL I BEAM IN AN APPROVED MANNER
Printed thickness prefix of bent-up angle anchors; leg dimensions, profile and attachment method not established.
Calculated from: core1013j-img_1129-m004
door-img1126-later-head-jambverified · printed
later_sill_slot_short_dimension
9/16″ × 1½″ SLOTS0.5625 in
Short slot dimension in sill fixing note; no slot count or installed station inferred.
door-img1126-later-head-jambverified · printed
later_sill_slot_long_dimension
9/16″ × 1½″ SLOTS1.5 in
Long slot dimension separately recorded from same printed note; not bolt length.
door-img1126-later-head-jambillegible · printed
later_sill_bolt_length_unresolved
[bolt head/diameter/length prefix not securely transcribed]Numeric value unresolved
Bolts are named, but exact head/diameter/length glyph sequence requires a clearer witness. No fraction reconstructed from expected hardware.
IMG_1129 · W-229 · Locate on drawing ↗Drawing notation: [bolt head/diameter/length prefix not securely transcribed]
Bolts are named, but exact head/diameter/length glyph sequence requires a clearer witness. No fraction reconstructed from expected hardware.
door-img1126-later-head-jambverified · printed
later_sill_lockwasher_relationship
NUT & LOCK WASHERS ON BOTH SIDESReadable washer relationship within sill bolt note; no numerical quantity or bolt size inferred.
door-img1126-later-head-jambverified · printed
later_sill_metal_fascia_gauge
14 GAUGE METAL FACIA14 gauge
Gauge note leader at sill underside; metal type unspecified, no thickness conversion.
door-img1126-later-head-jambverified · printed
later_sill_metal_fascia_material
14 GAUGE METAL FACIAPrinted generic metal fascia; do not assign steel solely from nearby head fascia.
door-img1126-later-head-jambunreviewed · printed
elevator3_sill_exception_material
[NOTE: SILL AT ELEV.3 AT DOOR ...] ANTI-SLIP ALUMINUMReadable aluminum material in jamb note; intervening floor/door applicability phrase remains unresolved, so no floor assignment.
IMG_1129 · W-229 · Locate on drawing ↗Drawing notation: [NOTE: SILL AT ELEV.3 AT DOOR ...] ANTI-SLIP ALUMINUM
Readable aluminum material in jamb note; intervening floor/door applicability phrase remains unresolved, so no floor assignment.
door-img1126-later-head-jambverified · printed
elevator3_first_floor_sill_material_exception
NOTE: SILL AT ELEV. 3 AT 1ST FL. TO BE ANTI-SLIP ALUMINUMSame original printed jamb/sill note as elevator1013p-1129-017. The phrase is1ST FL., not a door-number or unassigned floor. Resolves this note's material and first-floor applicability only; no installation, alloy, surface pattern, dimensions or revision choice.
IMG_1129 · W-229 · Locate on drawing ↗Drawing notation: NOTE: SILL AT ELEV. 3 AT 1ST FL. TO BE ANTI-SLIP ALUMINUM
Same original printed jamb/sill note as elevator1013p-1129-017. The phrase is1ST FL., not a door-number or unassigned floor. Resolves this note's material and first-floor applicability only; no installation, alloy, surface pattern, dimensions or revision choice.
door-img1126-later-head-jambverified · printed
shared_enclosure_applicability_elevators_1_2
TYPICAL DETAIL OF ELEVATOR ENCLOSURE FOR ELEVATORS #1 & #2 FOR BASEMENT,2ND TO5TH FLOORS(INCLUSIVE),AND FOR7TH FLOORShared later enclosure applies to these explicitly printed levels for elevators1/2. First-floor and sixth-floor details remain separate variants.
IMG_1129 · W-229 · Locate on drawing ↗Drawing notation: TYPICAL DETAIL OF ELEVATOR ENCLOSURE FOR ELEVATORS #1 & #2 FOR BASEMENT,2ND TO5TH FLOORS(INCLUSIVE),AND FOR7TH FLOOR
Shared later enclosure applies to these explicitly printed levels for elevators1/2. First-floor and sixth-floor details remain separate variants.
door-img1126-later-head-jambverified · printed
shared_enclosure_applicability_elevator_3
ALSO FOR ELEVATOR #3 FOR BASEMENT TO7TH FLOORS INCLUSIVEPrinted type applicability includes Elevator3 basement through7; no evidence that1/2 first- or sixth-floor variant also applies to3.
IMG_1129 · W-229 · Locate on drawing ↗Drawing notation: ALSO FOR ELEVATOR #3 FOR BASEMENT TO7TH FLOORS INCLUSIVE
Printed type applicability includes Elevator3 basement through7; no evidence that1/2 first- or sixth-floor variant also applies to3.
door-img1126-later-head-jambverified · printed
sill_anchor_field_drilling_note
DRILL ANCHORS IN FIELDField drilling note in common sill section; hole/anchor sizes, spacing and installed stations unresolved.
door-img1126-later-head-jambverified · printed
sill_anchor_to_steel_beam_relationship
BENT ANGLE ANCHORS TO STEEL I BEAM IN AN APPROVED MANNER [size prefix unresolved]Anchor is related to structural steel I-beam in common sill section. Approved manner is not an extracted fastening specification; size prefix withheld.
IMG_1129 · W-229 · Locate on drawing ↗Drawing notation: BENT ANGLE ANCHORS TO STEEL I BEAM IN AN APPROVED MANNER [size prefix unresolved]
Anchor is related to structural steel I-beam in common sill section. Approved manner is not an extracted fastening specification; size prefix withheld.