Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
detail-mech1338b-breaker-lighting-2verified · printed
switchboard
MAIN SWITCHBOARD LIGHTINGPrinted schedule property only. Stable extraction instance represents a schedule row; installed location/floor and physical equipment identity unresolved. Yellow handwriting is not substituted for original printed rating.
IMG_1338 · Locate on drawing ↗Drawing notation: MAIN SWITCHBOARD LIGHTING
Printed schedule property only. Stable extraction instance represents a schedule row; installed location/floor and physical equipment identity unresolved. Yellow handwriting is not substituted for original printed rating.
detail-mech1338b-breaker-lighting-2verified · printed
circuit_assignment
Feeder APrinted schedule property only. Stable extraction instance represents a schedule row; installed location/floor and physical equipment identity unresolved. Yellow handwriting is not substituted for original printed rating.
IMG_1338 · Locate on drawing ↗Drawing notation: Feeder A
Printed schedule property only. Stable extraction instance represents a schedule row; installed location/floor and physical equipment identity unresolved. Yellow handwriting is not substituted for original printed rating.
detail-mech1338b-breaker-lighting-2verified · printed
quantity
11 count
Printed schedule property only. Stable extraction instance represents a schedule row; installed location/floor and physical equipment identity unresolved. Yellow handwriting is not substituted for original printed rating.
IMG_1338 · Locate on drawing ↗Drawing notation: 1
Printed schedule property only. Stable extraction instance represents a schedule row; installed location/floor and physical equipment identity unresolved. Yellow handwriting is not substituted for original printed rating.
detail-mech1338b-breaker-lighting-2unreviewed · printed
rating_amperes
Original printed rating obscured by yellow handwritten revisionNumeric value unresolved
Printed schedule property only. Stable extraction instance represents a schedule row; installed location/floor and physical equipment identity unresolved. Yellow handwriting is not substituted for original printed rating.
IMG_1338 · Locate on drawing ↗Drawing notation: Original printed rating obscured by yellow handwritten revision
Printed schedule property only. Stable extraction instance represents a schedule row; installed location/floor and physical equipment identity unresolved. Yellow handwriting is not substituted for original printed rating.
detail-mech1338b-breaker-lighting-2verified · printed
poles
33 count
Printed schedule property only. Stable extraction instance represents a schedule row; installed location/floor and physical equipment identity unresolved. Yellow handwriting is not substituted for original printed rating.
IMG_1338 · Locate on drawing ↗Drawing notation: 3
Printed schedule property only. Stable extraction instance represents a schedule row; installed location/floor and physical equipment identity unresolved. Yellow handwriting is not substituted for original printed rating.
detail-mech1338b-breaker-lighting-2verified · observed
yellow_overmark_rating_amperes
FEEDER "A" / SIZE AMP. / yellow 400400 A
Observed yellow handwritten numeral in the named MAIN SWITCHBOARD LIGHTING row under independently legible SIZE AMP. header. Governing issue/date and original white printed rating under the overmark remain unresolved; this does not replace or close the original-rating record.
IMG_1338 · Locate on drawing ↗Drawing notation: FEEDER "A" / SIZE AMP. / yellow 400
Observed yellow handwritten numeral in the named MAIN SWITCHBOARD LIGHTING row under independently legible SIZE AMP. header. Governing issue/date and original white printed rating under the overmark remain unresolved; this does not replace or close the original-rating record.
Calculated from: servicesched1013f-img1338-004-breaker_rating_header
Conflicting readings: detail-mech1338b-m009