Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
detail-img1314-typical-beam-connectionverified · printed
connection_angle_literal
3½″ × 3½″ × ⅜″Same pair of printed angle callouts in BEAM CONNECTIONS detail as prior unresolved connection_angle_notation; lettering is upright at raw rotation0. Not an installed-member assignment.
IMG_1314 · W-400 · Locate on drawing ↗Drawing notation: 3½″ × 3½″ × ⅜″
Same pair of printed angle callouts in BEAM CONNECTIONS detail as prior unresolved connection_angle_notation; lettering is upright at raw rotation0. Not an installed-member assignment.
detail-img1314-typical-beam-connectionverified · printed
application
FOR ALL FLOORS EXCEPT AS OTHERWISE NOTEDPrinted detail-local property; no accepted building placement, historical quantity or exact room geometry inferred.
IMG_1314 · W-400 · Locate on drawing ↗Drawing notation: FOR ALL FLOORS EXCEPT AS OTHERWISE NOTED
Printed detail-local property; no accepted building placement, historical quantity or exact room geometry inferred.
detail-img1314-typical-beam-connectionverified · printed
load_condition
WHERE LOADS ARE SHOWN ON BEAMS, CONNECTIONS MUST BE MADE TO SUIT IF STANDARD CONNECTIONS ARE NOT SUFFICIENTPrinted detail-local property; no accepted building placement, historical quantity or exact room geometry inferred.
IMG_1314 · W-400 · Locate on drawing ↗Drawing notation: WHERE LOADS ARE SHOWN ON BEAMS, CONNECTIONS MUST BE MADE TO SUIT IF STANDARD CONNECTIONS ARE NOT SUFFICIENT
Printed detail-local property; no accepted building placement, historical quantity or exact room geometry inferred.
detail-img1314-typical-beam-connectionverified · printed
fabrication_condition
ATTENTION PARTICULARLY CALLED TO BEAMS FABRICATED OF MORE THAN ONE PIECEPrinted detail-local property; no accepted building placement, historical quantity or exact room geometry inferred.
IMG_1314 · W-400 · Locate on drawing ↗Drawing notation: ATTENTION PARTICULARLY CALLED TO BEAMS FABRICATED OF MORE THAN ONE PIECE
Printed detail-local property; no accepted building placement, historical quantity or exact room geometry inferred.
detail-img1314-typical-beam-connectionunreviewed · printed
connection_angle_notation
[fine angle notation unresolved]Printed detail-local property; no accepted building placement, historical quantity or exact room geometry inferred.
IMG_1314 · W-400 · Locate on drawing ↗Drawing notation: [fine angle notation unresolved]
Printed detail-local property; no accepted building placement, historical quantity or exact room geometry inferred.
detail-img1314-typical-beam-connectionverified · printed
angle_leg_1
3½″ × 3½″ × ⅜″3.5 in
Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.
detail-img1314-typical-beam-connectionverified · printed
angle_leg_2
3½″ × 3½″ × ⅜″3.5 in
Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.
detail-img1314-typical-beam-connectionverified · printed
angle_thickness
3½″ × 3½″ × ⅜″0.375 in
Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.
detail-img1314-typical-beam-connectionverified · printed
connection_standard_notation
STD CONN.Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.