Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
detail-img1304-stamps-signverified · printed
sign-lettering
STAMPSPrinted source-local specification/detail only. No installed quantity, accepted room geometry or building transform established; no cross-sheet revision equivalence assumed.
IMG_1304 · W-216 · Locate on drawing ↗Drawing notation: STAMPS
Printed source-local specification/detail only. No installed quantity, accepted room geometry or building transform established; no cross-sheet revision equivalence assumed.
detail-img1304-stamps-signverified · printed
sign-glazing
WHITE OPAL FLASHED GLASSPrinted source-local specification/detail only. No installed quantity, accepted room geometry or building transform established; no cross-sheet revision equivalence assumed.
IMG_1304 · W-216 · Locate on drawing ↗Drawing notation: WHITE OPAL FLASHED GLASS
Printed source-local specification/detail only. No installed quantity, accepted room geometry or building transform established; no cross-sheet revision equivalence assumed.
detail-img1304-stamps-signverified · printed
frame-wall-plate-material
BRONZE FRAME & WALL PLATEPrinted source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
IMG_1304 · W-216 · Locate on drawing ↗Drawing notation: BRONZE FRAME & WALL PLATE
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
detail-img1304-stamps-signverified · printed
plan-length-witness
1'-2"14 in
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
IMG_1304 · W-216 · Locate on drawing ↗Drawing notation: 1'-2"
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
detail-img1304-stamps-signverified · printed
end-width-witness
6"6 in
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
IMG_1304 · W-216 · Locate on drawing ↗Drawing notation: 6"
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
detail-img1304-stamps-signverified · printed
required-sign-count-0
STAMPS 11 count
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
IMG_1304 · W-216 · Locate on drawing ↗Drawing notation: STAMPS 1
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
detail-img1304-stamps-signverified · printed
required-sign-count-1
REGISTRY 11 count
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
IMG_1304 · W-216 · Locate on drawing ↗Drawing notation: REGISTRY 1
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
detail-img1304-stamps-signverified · printed
required-sign-count-2
INQUIRY 11 count
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
IMG_1304 · W-216 · Locate on drawing ↗Drawing notation: INQUIRY 1
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
detail-img1304-stamps-signverified · printed
required-sign-count-3
LETTER DROP 11 count
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
IMG_1304 · W-216 · Locate on drawing ↗Drawing notation: LETTER DROP 1
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
detail-img1304-stamps-signverified · printed
required-sign-count-4
PARCEL POST 11 count
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
IMG_1304 · W-216 · Locate on drawing ↗Drawing notation: PARCEL POST 1
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
detail-img1304-stamps-signverified · printed
required-sign-count-5
MONEY ORDER 11 count
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
IMG_1304 · W-216 · Locate on drawing ↗Drawing notation: MONEY ORDER 1
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
detail-img1304-stamps-signverified · printed
required-sign-count-6
POSTAL SAVING 11 count
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.
IMG_1304 · W-216 · Locate on drawing ↗Drawing notation: POSTAL SAVING 1
Printed source-local construction/detail only. Dimension witnesses remain local; no accepted geometry, installed placement or revision precedence established.