Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
detail-facade-1236-court-sill-chainverified · printed
fifth_floor_reference_to_opening_sill
2′3½″27.5 in
Lower F5 floor reference line to graphic sill witness of window5/48. Sill/frame/masonry class unresolved.
detail-facade-1236-court-sill-chainverified · printed
fifth_opening_head_to_sixth_floor_reference
2′8½″32.5 in
Graphic head of F5 window5/48 to next/F6 floor reference. A separate head-to-floor term, not window height.
detail-facade-1236-court-sill-chainverified · printed
sixth_floor_reference_to_opening_sill
2′3½″27.5 in
F6 floor reference line to graphic sill witness of window6/48. Separate literal fraction from F5 despite repeated value.
detail-facade-1236-court-sill-chainverified · printed
sixth_opening_head_to_lower_seventh_floor_reference
2′8½″32.5 in
Graphic F6 window6/48 head to lower/Main seventh-floor reference. Does not use higher south-end floor datum.
detail-facade-1236-court-sill-chainverified · printed
lower_main_seventh_floor_reference_to_opening_sill
4′3½″51.5 in
Lower/Main F7 reference to graphic sill of window7/44. Distinct witness from raised south-end floor to same sill.
detail-facade-1236-court-sill-chainverified · printed
raised_south_end_seventh_floor_reference_to_opening_sill
2′3½″27.5 in
Raised south-end F7 reference to same graphic sill of window7/44. Existing2′0″ step remains independent; no regional flattening.
detail-facade-1236-court-sill-chainverified · printed
seventh_opening_head_to_eighth_floor_reference
2′8½″32.5 in
Graphic head of window7/44 to F8 floor reference. Top of this crop excludes remaining F8 head/sill terms.
detail-facade-1236-court-sill-chainverified · derived
fractional_step_witness_closure
4′3½″ − 2′3½″ = 2′0″24 in
Independent printed fractions differ by24in, matching existing printed2ft regional step. This is a check of separate source witnesses; it cannot locate the floor transition in plan.
IMG_1236 · sheet-W105 · Locate on drawing ↗Drawing notation: 4′3½″ − 2′3½″ = 2′0″
Independent printed fractions differ by24in, matching existing printed2ft regional step. This is a check of separate source witnesses; it cannot locate the floor transition in plan.
Calculated from: section1013j-court-f7-main-sill, section1013j-court-f7-south-sill, ms-F7-main-madison-step-printed
detail-facade-1236-court-sill-chainunreviewed · printed
fifth-floor-sill-fraction-unresolved
2'-3[small fraction unresolved]Numeric value unresolved
Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved.
IMG_1236 · sheet-W105 · Locate on drawing ↗Drawing notation: 2'-3[small fraction unresolved]
Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved.
Conflicting readings: ms-court-fractional-sill-F5-unresolved
detail-facade-1236-court-sill-chainunreviewed · printed
seventh-floor-left-sill-fraction-unresolved
4'-3[small fraction unresolved]Numeric value unresolved
Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved.
IMG_1236 · sheet-W105 · Locate on drawing ↗Drawing notation: 4'-3[small fraction unresolved]
Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved.
Conflicting readings: ms-court-fractional-sill-F7-unresolved