Object: Elevator No. 3 shaft and neighboring services
Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
detail-elevator3-sixth-witness-1011lverified · printed
steel-stack-nominal-size-reread
42″ STEEL STACK42 in
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Same circle label previously transcribed12-inch. Printed nominal stack size only; no wall thickness or accepted shaft geometry.
IMG_1181 · W-242 · Locate on drawing ↗Drawing notation: 42″ STEEL STACK
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Same circle label previously transcribed12-inch. Printed nominal stack size only; no wall thickness or accepted shaft geometry.
detail-elevator3-sixth-witness-1011lverified · printed
elevator-vertical-witness-reread
7′-4¾″88.75 in
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Same inner elevatorNo3 vertical witness previously read7′-7¼″; source drawing control, not acceptance of installed shaft dimensions.
IMG_1181 · W-242 · Locate on drawing ↗Drawing notation: 7′-4¾″
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Same inner elevatorNo3 vertical witness previously read7′-7¼″; source drawing control, not acceptance of installed shaft dimensions.
detail-elevator3-sixth-witness-1011lverified · printed
service-enclosure-inner-vertical-witness
6′-0″72 in
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Inner vertical enclosure witness above ElevatorNo3; no room label identified, no assignment to608 or607.
IMG_1181 · W-242 · Locate on drawing ↗Drawing notation: 6′-0″
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Inner vertical enclosure witness above ElevatorNo3; no room label identified, no assignment to608 or607.
detail-elevator3-sixth-witness-1011lverified · printed
service-soil-pipe-size
4″ SOIL4 in
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Printed service size/function; exact pipe material and installation quantity unknown.
IMG_1181 · W-242 · Locate on drawing ↗Drawing notation: 4″ SOIL
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Printed service size/function; exact pipe material and installation quantity unknown.
detail-elevator3-sixth-witness-1011lverified · printed
service-vs-size
5″ V.S.5 in
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Literal V.S. mark preserved; no expanded historical designation asserted.
IMG_1181 · W-242 · Locate on drawing ↗Drawing notation: 5″ V.S.
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Literal V.S. mark preserved; no expanded historical designation asserted.
detail-elevator3-sixth-witness-1011lverified · printed
shaft_horizontal_witness
6'-8"80 in
Selected printed source-local evidence only; exact endpoints, physical installation and governing revision unresolved.
detail-elevator3-sixth-witness-1011lunreviewed · printed
shaft_vertical_witness
7'-7¼"91.25 in
Selected printed source-local evidence only; exact endpoints, physical installation and governing revision unresolved. Review correction review-correction-20261013r-detail-1178-1187-20261011l-1181-m002: Same original inner ElevatorNo3 vertical witness reads7′-4¾″=88.75in rather than7′-7¼″=91.25in.
detail-elevator3-sixth-witness-1011lunreviewed · printed
neighboring_steel_stack
12" STEEL STACK12 in
Selected printed source-local evidence only; exact endpoints, physical installation and governing revision unresolved. Review correction review-correction-20261013r-detail-1178-1187-20261011l-1181-m003: Same original circle annotation reads42″ STEEL STACK rather than12″; source nominal-size transcription only.
detail-elevator3-sixth-witness-1011lverified · printed
neighboring_iron_ladder
IRON LADDERSelected printed source-local evidence only; exact endpoints, physical installation and governing revision unresolved.
detail-elevator3-sixth-witness-1011lverified · printed
neighboring_service_enclosure_horizontal_witness
9′-1″109 in
Local horizontal witness inside service enclosure above Elevator3 containing labeled soil/steel-stack/iron-ladder features. Enclosure room identity unresolved; not assigned to judges stenographer608, elevator shaft or Library607.
IMG_1181 · Locate on drawing ↗Drawing notation: 9′-1″
Local horizontal witness inside service enclosure above Elevator3 containing labeled soil/steel-stack/iron-ladder features. Enclosure room identity unresolved; not assigned to judges stenographer608, elevator shaft or Library607.