Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
detail-courts-20261010-img1172-assemblyverified · printed
bench-platform-inner-vertical-witness
5′-10″70 in
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Inner vertical witness within judge platform adjacent to desk, ending at labeled rough-concrete line. Endpoint construction faces remain unclassified.
IMG_1172 · W-240 · Locate on drawing ↗Drawing notation: 5′-10″
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Inner vertical witness within judge platform adjacent to desk, ending at labeled rough-concrete line. Endpoint construction faces remain unclassified.
detail-courts-20261010-img1172-assemblyverified · printed
bench-platform-outer-vertical-witness
7′-4″88 in
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Separate outer vertical platform witness adjacent to 5′-10″; do not collapse distinct endpoints.
IMG_1172 · W-240 · Locate on drawing ↗Drawing notation: 7′-4″
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Separate outer vertical platform witness adjacent to 5′-10″; do not collapse distinct endpoints.
detail-courts-20261010-img1172-assemblyverified · printed
bench-platform-rough-concrete-line
ROUGH CONCRETE LINEPrinted source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry.
IMG_1172 · W-240 · Locate on drawing ↗Drawing notation: ROUGH CONCRETE LINE
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry.
detail-courts-20261010-img1172-assemblyverified · printed
bench-platform-tile-floor-steps
RUBBER TILE FLOOR & STEPSPrinted source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry.
IMG_1172 · W-240 · Locate on drawing ↗Drawing notation: RUBBER TILE FLOOR & STEPS
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry.
detail-courts-20261010-img1172-assemblyverified · printed
court_floor_tile_size
12" x 12" DIAGONAL SQUARES12 in
Courtroom plan floor note; each square side dimension, laid diagonally; no room perimeter dimensions inferred.
IMG_1172 · W-240 · Locate on drawing ↗Drawing notation: 12" x 12" DIAGONAL SQUARES
Courtroom plan floor note; each square side dimension, laid diagonally; no room perimeter dimensions inferred.
detail-courts-20261010-img1172-assemblyverified · printed
court_floor_tile_orientation
DIAGONAL SQUARESCourtroom floor tile orientation; no calculated tile count.
detail-courts-20261010-img1172-assemblyverified · printed
court-plan-bottom-chain-local-interval
14'-0"14 ft
One labelled interval in lowest courtroom plan chain, drawing-local; endpoints need grid/station classification. Does not establish complete courtroom width, wall placement or a 602/612 module.
IMG_1172 · W-240 · Locate on drawing ↗Drawing notation: 14'-0"
One labelled interval in lowest courtroom plan chain, drawing-local; endpoints need grid/station classification. Does not establish complete courtroom width, wall placement or a 602/612 module.