Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
detail-20261011o-img1327-vault-wallverified · printed
vertical_bar_spacing
VERTICAL RODS EXTEND FROM FLOOR SLAB TO TOP OF CEILING SLAB VERT RODS 12" C. BOTH FACES STAGGERED12 in
Printed vault wall spacing; both-face staggered assignment retained.
IMG_1327 · W-413 · Locate on drawing ↗Drawing notation: VERTICAL RODS EXTEND FROM FLOOR SLAB TO TOP OF CEILING SLAB VERT RODS 12" C. BOTH FACES STAGGERED
Printed vault wall spacing; both-face staggered assignment retained.
detail-20261011o-img1327-vault-wallverified · printed
vertical_bar_relationship
VERTICAL RODS EXTEND FROM FLOOR SLAB TO TOP OF CEILING SLABPrinted endpoints are generic detail relationships, not registered building elevations.
IMG_1327 · W-413 · Locate on drawing ↗Drawing notation: VERTICAL RODS EXTEND FROM FLOOR SLAB TO TOP OF CEILING SLAB
Printed endpoints are generic detail relationships, not registered building elevations.
detail-20261011o-img1327-vault-wallverified · printed
horizontal_bar_spacing
HORIZ. BARS 6" O.C. ALL BARS BENT6 in
Printed wall horizontal bar spacing.
detail-20261011o-img1327-vault-wallunresolved · printed
straight_bar_end_treatment
ALL STRAIGHT BARS HOOKED ONE END STRAIGHT ENDSFinal wording visibly incomplete/ambiguous in access crop; exact hook/stagger requirement must be checked at higher resolution.
IMG_1327 · W-413 · Locate on drawing ↗Drawing notation: ALL STRAIGHT BARS HOOKED ONE END STRAIGHT ENDS
Final wording visibly incomplete/ambiguous in access crop; exact hook/stagger requirement must be checked at higher resolution.
detail-20261011o-img1327-vault-wallverified · printed
straight_bar_end_treatment
ALL STRAIGHT BARS HOOKED ONE END STAGGER ENDS.Master crop resolves prior ambiguous final wording; generic vault detail only.
detail-20261011o-img1327-vault-wallunresolved · printed
all_vault_steel_diameter_candidate
ALL STEEL IN VAULTS TO BE ½ [round glyph]0.5 in
Half-inch fraction appears legible; final section glyph still needs independent check. Candidate preserved separately from prior null.
IMG_1327 · W-413 · Locate on drawing ↗Drawing notation: ALL STEEL IN VAULTS TO BE ½ [round glyph]
Half-inch fraction appears legible; final section glyph still needs independent check. Candidate preserved separately from prior null.
detail-20261011o-img1327-vault-wallverified · printed
steel_surface_relation
STEEL FLUSH WITH CONC.Source-local leader at generic vault wall detail; no cover dimension inferred.