head_channel_depth
6" CHANNEL6 in
Sixth-floor typical head steel channel callout; channel section weight pending.
Drawing notation: 6" CHANNEL
Sixth-floor typical head steel channel callout; channel section weight pending.
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Object: detail 1129 sixth enclosure
Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
6 in
Sixth-floor typical head steel channel callout; channel section weight pending.
Drawing notation: 6" CHANNEL
Sixth-floor typical head steel channel callout; channel section weight pending.
6 in
Sixth/seventh-floor typical jamb section channel; material inferred by channel drawing is not added.
Drawing notation: 6" CHANNEL
Sixth/seventh-floor typical jamb section channel; material inferred by channel drawing is not added.
1.5 in
Upper horizontal chain of sixth-floor head; local witness endpoints, not opening width.
Drawing notation: 1 1/2"
Upper horizontal chain of sixth-floor head; local witness endpoints, not opening width.
4.75 in
Head horizontal witness from channel-side datum to fascia plane.
Drawing notation: 4 3/4"
Head horizontal witness from channel-side datum to fascia plane.
14 gauge
Gauge designation retained as gauge; no gauge-to-thickness conversion.
Drawing notation: 14 GA. STEEL HINGED OR REMOVABLE COVER PLATE
Gauge designation retained as gauge; no gauge-to-thickness conversion.
Explicit steel cover and allowed hinged/removable alternatives; no installed selection inferred.
Drawing notation: 14 GA. STEEL HINGED OR REMOVABLE COVER PLATE
Explicit steel cover and allowed hinged/removable alternatives; no installed selection inferred.
0.1875 in
Printed hinge plate thickness, not channel wall thickness.
Drawing notation: 3/16" STEEL HINGE PLATE
Printed hinge plate thickness, not channel wall thickness.
Steel material explicitly stated.
Drawing notation: 3/16" STEEL HINGE PLATE
Steel material explicitly stated.
14 gauge
Fascia designation in sixth-floor sill detail.
Drawing notation: 14 GA. STEEL FACIA
Fascia designation in sixth-floor sill detail.
Printed steel fascia in sill detail.
Drawing notation: 14 GA. STEEL FACIA
Printed steel fascia in sill detail.
6.375 in
Local width witness of anti-slip bronze sill section; operating door width not implied.
Drawing notation: 6 3/8"
Local width witness of anti-slip bronze sill section; operating door width not implied.
4.75 in
Horizontal outer chain at sixth/seventh-floor jamb detail.
Drawing notation: 4 3/4"
Horizontal outer chain at sixth/seventh-floor jamb detail.
5.625 in
Lower horizontal chain at jamb-detail sill; exact endpoint finish classification pending.
Drawing notation: 5 5/8"
Lower horizontal chain at jamb-detail sill; exact endpoint finish classification pending.
Source inventory is separate from the floor filters above. Select one drawing to inspect it; no drawing set is preloaded.