Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
column-82unreviewed · traced
world x foundation trace
48.40126866203316 ft (provisional trace)48.401269 ft · estimated uncertainty ±2.013766985 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
column-82unreviewed · traced
world z foundation trace
55.901452387055684 ft (provisional trace)55.901452 ft · estimated uncertainty ±2.013766985 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
w409-group-I19verified · printed
basePlate.B
B 4040 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-I19verified · printed
basePlate.L
L 4141 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-I19unreviewed · printed
basePlate.T
T 44 in
Thickness fraction deserves renewed high-resolution verification before fabrication or geometry.
w409-group-I19unreviewed · printed
topOfBasePlate.offsetFromBasementScheduleLine
10′6″The distance arrow is printed; sign, baseline, and assignment to each grouped mark require a targeted recheck. This is not an absolute foot elevation.
column-82verified · printed
W224_common_axis_with_column68
Columns 82 and 68 share the W224 longitudinal reference axisCommon axis stated by the detail. Absolute canonical X remains unresolved.
column-82unreviewed · observed
observed_alignment_with_main_perimeter_column94
C82 appears on the C94 transverse stationCandidate alignment, not an accepted equality of canonical X coordinates.
IMG_1211 · Locate on drawing ↗Drawing notation: 82 / 94
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Support symbols are visually aligned through the office partition. No independent numeric offset or securely identified continuous centerline witness was verified.
column-82unreviewed · observed
observed_alignment_with_broadway_perimeter_column84
C82 appears in the C83–C84 corridor-side rowCandidate alignment, not an accepted equality of canonical Z coordinates.
IMG_1211 · Locate on drawing ↗Drawing notation: 82 / 83 / 84
Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. The wall and structural-rod graphics overlap the row; a verified column-center witness line or dimension chain is still needed.
column-82unreviewed · observed
accepted_third_floor_world_x
UnresolvedNumeric value unresolved
Existing interior-column coordinates are foundation traces; candidate C94 alignment not accepted.
IMG_1211 · Locate on drawing ↗Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Existing interior-column coordinates are foundation traces; candidate C94 alignment not accepted.
column-82unreviewed · observed
accepted_third_floor_world_z
UnresolvedNumeric value unresolved
Existing interior-column coordinates are foundation traces; candidate C84 alignment not accepted.
IMG_1211 · Locate on drawing ↗Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Existing interior-column coordinates are foundation traces; candidate C84 alignment not accepted.
control-w400-interior-68-82unreviewed · observed
framing.observedLongitudinalIncidence
A connected, apparently straight beam/girder line passes through the drawn support symbols C10, C68, C82 and C94.Observed structural incidence, not a printed zero transverse offset. Only the endpoint/support identities C10/C68/C82/C94 are assigned; intermediate marks are not transcribed in this bounded task.
column-82unreviewed · observed
framing.observedTransverseIncidence
A connected transverse framing line runs through C82, C83 and C84.control-w402-interior-68-82unreviewed · observed
framing.observedLongitudinalIncidence
A connected, apparently straight beam/girder line passes through the drawn support symbols C10, C68, C82 and C94.Observed structural incidence, not a printed zero transverse offset. Only the endpoint/support identities C10/C68/C82/C94 are assigned; intermediate marks are not transcribed in this bounded task.
column-82unreviewed · observed
framing.observedTransverseIncidence
A connected transverse framing line runs through C82, C83 and C84.column-82unreviewed · derived
coordinationCandidate.worldX
49′0″, conditional on zero column-center offset from the C10/C94 longitudinal framing line49 ft
Calculated from: interior-68-82-w400-perimeter-x-station, interior-68-82-w402-perimeter-x-station, interior-68-82-w400-longitudinal-framing-incidence, interior-68-82-w402-longitudinal-framing-incidence, assumption-interior-longitudinal-framing-line-equals-column-control
column-82unreviewed · derived
coordinationCandidate.worldZ
56′0″, conditional on zero column-center offset from the transverse C82/C84 framing line56 ft
Calculated from: interior-68-82-w400-perimeter-z-84, interior-68-82-w400-transverse-82-84, interior-68-82-w402-transverse-82-84, assumption-column-82-transverse-line-equals-column-control
column-82unreviewed · observed
columnCenter.offsetFromFramingReferenceX
Unresolved column-control X offset from the nominal framing referenceNumeric value unresolved
No numeric offset is inferred from image pixels or from the foundation trace. Null does not mean zero.
column-82unreviewed · derived
acceptedWorldX
Unresolved: conditional framing-line transfer is not an accepted column coordinateNumeric value unresolved
Do not populate structural-registration.worldColumns from the candidate without resolving the control-to-column-center tie.
Calculated from: interior-68-82-column-82-candidate-x, interior-68-82-column-82-offset-x
column-82unreviewed · observed
columnCenter.offsetFromFramingReferenceZ
Unresolved column-control Z offset from the nominal framing referenceNumeric value unresolved
No numeric offset is inferred from image pixels or from the foundation trace. Null does not mean zero.
column-82unreviewed · derived
acceptedWorldZ
Unresolved: conditional framing-line transfer is not an accepted column coordinateNumeric value unresolved
Do not populate structural-registration.worldColumns from the candidate without resolving the control-to-column-center tie.
Calculated from: interior-68-82-column-82-candidate-z, interior-68-82-column-82-offset-z
column-68unreviewed · inferred
Unaccepted framing incidence assumption
The connected longitudinal framing path through C10/C68/C82/C94 coincides with the exact column-control axis without an unmarked transverse offset.The drawn beam/girder line may describe a member line or framing connection rather than the exact center of an eccentrically connected column. Schematic one-line representations do not prove zero eccentricity.
column-82unreviewed · inferred
Unaccepted framing incidence assumption
Transverse framing line through C82 and perimeter C84 supplies the same Z control to both column centers.An eccentric attachment, unrecorded local center offset or schematic beam endpoint may differ from the actual column-control center.