Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
column-66unreviewed · traced
world x foundation trace
20.77566214251781 ft (provisional trace)20.775662 ft · estimated uncertainty ±2.037067292 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
column-66unreviewed · traced
world z foundation trace
27.66980731686948 ft (provisional trace)27.669807 ft · estimated uncertainty ±2.037067292 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
w409-group-L10verified · printed
basePlate.B
B 3232 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-L10verified · printed
basePlate.L
L 3535 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-L10unreviewed · printed
basePlate.T
T 3¾3.75 in
Thickness fraction deserves renewed high-resolution verification before fabrication or geometry.
w409-group-L10unreviewed · printed
topOfBasePlate.offsetFromBasementScheduleLine
2′4″The distance arrow is printed; sign, baseline, and assignment to each grouped mark require a targeted recheck. This is not an absolute foot elevation.