Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
column-4verified · derived
Page-right coordinate from C1
44.583333333333336 ft44.583333 ft
First-floor plan coordinates only; not yet registered to building west/north axes.
Calculated from: frame-top-column-bays, frame-left-column-bays
column-4verified · derived
Page-down coordinate from C1
0 ft0 ft
First-floor plan coordinates only; not yet registered to building west/north axes.
Calculated from: frame-top-column-bays, frame-left-column-bays
column-4verified · derived
world x
-33.99999999999999 ft (calculated)-34 ft
Arithmetic of verified printed column bays in the shared +X west / +Z north system; no claim of as-built survey precision.
Calculated from: column-4-plan-x, structural-registration-origin-half-span
column-4verified · derived
world z
-78.58333333333333 ft (calculated)-78.583333 ft
Arithmetic of verified printed column bays in the shared +X west / +Z north system; no claim of as-built survey precision.
Calculated from: column-4-plan-y, structural-registration-origin-half-span
column-4unreviewed · traced
world x foundation trace
-34.21589875243004 ft (provisional trace)-34.215899 ft · estimated uncertainty ±2.23522313 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
column-4unreviewed · traced
world z foundation trace
-79.6797695923407 ft (provisional trace)-79.67977 ft · estimated uncertainty ±2.23522313 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
w409-group-E01verified · printed
basePlate.B
B 4040 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-E01verified · printed
basePlate.L
L 5353 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-E01unreviewed · printed
topOfBasePlate.offsetFromBasementScheduleLine
1′6″The distance arrow is printed; sign, baseline, and assignment to each grouped mark require a targeted recheck. This is not an absolute foot elevation.
column-4unreviewed · printed
schedule.spliceOffsetAtFourthFloor
2′0″ SPLICE2 ft
Source review: printed-reference; individual-fabrication-level-not-accepted. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4unreviewed · printed
schedule.spliceOffsetAtSixthFloor
2′0″ SPLICE2 ft
Source review: printed-reference; individual-fabrication-level-not-accepted. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4verified · printed
schedule.lowerSpliceOffset
3′6″ SPLICE3.5 ft
Source review: checked-master-crop. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4illegible · printed
schedule.topOffset
TOP OF COLS [offset/reference relationship unresolved]Source review: unresolved. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4unreviewed · printed
channel.section
No channel section has been transcribed from these exterior body cells.Source review: untranscribed; not-evidence-of-absence. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4verified · derived
steelCenter.worldX
printed C1–C12 bay chain-34 ft
verified-perimeter-control. One-axis source result; no pad solid or accepted world Z bounds.
IMG_1328 · Locate on drawing ↗Drawing notation: printed C1–C12 bay chain
C16 bounded extraction; verified-perimeter-control. Z placement remains unresolved.