Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
column-26verified · derived
Page-right coordinate from C1
157.16666666666669 ft157.166667 ft
First-floor plan coordinates only; not yet registered to building west/north axes.
Calculated from: frame-top-column-bays, frame-left-column-bays
column-26verified · derived
Page-down coordinate from C1
36.58333333333333 ft36.583333 ft
First-floor plan coordinates only; not yet registered to building west/north axes.
Calculated from: frame-top-column-bays, frame-left-column-bays
column-26verified · derived
world x
78.58333333333336 ft (calculated)78.583333 ft
Arithmetic of verified printed column bays in the shared +X west / +Z north system; no claim of as-built survey precision.
Calculated from: column-26-plan-x, structural-registration-origin-half-span
column-26verified · derived
world z
-42 ft (calculated)-42 ft
Arithmetic of verified printed column bays in the shared +X west / +Z north system; no claim of as-built survey precision.
Calculated from: column-26-plan-y, structural-registration-origin-half-span
column-26unreviewed · traced
world x foundation trace
78.4543816608711 ft (provisional trace)78.454382 ft · estimated uncertainty ±2.270436489 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
column-26unreviewed · traced
world z foundation trace
-42.357198802859735 ft (provisional trace)-42.357199 ft · estimated uncertainty ±2.270436489 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
w409-group-E12verified · printed
basePlate.B
B 3232 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-E12verified · printed
basePlate.L
L 3333 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-E12unreviewed · printed
basePlate.T
T 3¾3.75 in
Thickness fraction deserves renewed high-resolution verification before fabrication or geometry.
column-4unreviewed · printed
schedule.spliceOffsetAtFourthFloor
2′0″ SPLICE2 ft
Source review: printed-reference; individual-fabrication-level-not-accepted. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4unreviewed · printed
schedule.spliceOffsetAtSixthFloor
2′0″ SPLICE2 ft
Source review: printed-reference; individual-fabrication-level-not-accepted. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4illegible · printed
schedule.topOffset
TOP OF COLS [offset/reference relationship unresolved]Source review: unresolved. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4unreviewed · printed
channel.section
No channel section has been transcribed from these exterior body cells.Source review: untranscribed; not-evidence-of-absence. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.