Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
column-24verified · derived
Page-right coordinate from C1
157.16666666666669 ft157.166667 ft
First-floor plan coordinates only; not yet registered to building west/north axes.
Calculated from: frame-top-column-bays, frame-left-column-bays
column-24verified · derived
Page-down coordinate from C1
22.583333333333332 ft22.583333 ft
First-floor plan coordinates only; not yet registered to building west/north axes.
Calculated from: frame-top-column-bays, frame-left-column-bays
column-24verified · derived
world x
78.58333333333336 ft (calculated)78.583333 ft
Arithmetic of verified printed column bays in the shared +X west / +Z north system; no claim of as-built survey precision.
Calculated from: column-24-plan-x, structural-registration-origin-half-span
column-24verified · derived
world z
-56 ft (calculated)-56 ft
Arithmetic of verified printed column bays in the shared +X west / +Z north system; no claim of as-built survey precision.
Calculated from: column-24-plan-y, structural-registration-origin-half-span
column-24unreviewed · traced
world x foundation trace
78.61999728735535 ft (provisional trace)78.619997 ft · estimated uncertainty ±2.303333476 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
column-24unreviewed · traced
world z foundation trace
-56.512310131777824 ft (provisional trace)-56.51231 ft · estimated uncertainty ±2.303333476 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
w409-group-E11verified · printed
basePlate.B
B 3434 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-E11verified · printed
basePlate.L
L 3636 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-E11unreviewed · printed
basePlate.T
T 3¾3.75 in
Thickness fraction deserves renewed high-resolution verification before fabrication or geometry.
column-4unreviewed · printed
schedule.spliceOffsetAtFourthFloor
2′0″ SPLICE2 ft
Source review: printed-reference; individual-fabrication-level-not-accepted. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4unreviewed · printed
schedule.spliceOffsetAtSixthFloor
2′0″ SPLICE2 ft
Source review: printed-reference; individual-fabrication-level-not-accepted. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4illegible · printed
schedule.topOffset
TOP OF COLS [offset/reference relationship unresolved]Source review: unresolved. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4unreviewed · printed
channel.section
No channel section has been transcribed from these exterior body cells.Source review: untranscribed; not-evidence-of-absence. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-24unreviewed · derived
steelCenter.worldX
+78′7″ from square center78.583333 ft
Candidate only. Nominal schedule size and vertical range do not establish an accepted world X/Z pad box.
IMG_1314 · sheet-W400 · View drawing ↗Drawing notation: +78′7″ from square center
C24 bounded repick; printed-column-control, not newly image checked. Reused research/reconstruction/structural-registration.json. See sequential reviewed regions in source package.
column-24unreviewed · derived
steelCenter.worldZ
−56′0″ from square center-56 ft
Candidate only. Nominal schedule size and vertical range do not establish an accepted world X/Z pad box.
IMG_1314 · sheet-W400 · View drawing ↗Drawing notation: −56′0″ from square center
C24 bounded repick; printed-column-control, not newly image checked. Reused research/reconstruction/structural-registration.json. See sequential reviewed regions in source package.