Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
column-15unreviewed · traced
world x foundation trace
-49.3150577039805 ft (provisional trace)-49.315058 ft · estimated uncertainty ±2.191923542 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
column-15unreviewed · traced
world z foundation trace
-56.026003747206545 ft (provisional trace)-56.026004 ft · estimated uncertainty ±2.191923542 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
w409-group-I01verified · printed
basePlate.B
B 3737 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-I01verified · printed
basePlate.L
L 4040 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-I01unreviewed · printed
basePlate.T
T 4¼4.25 in
Thickness fraction deserves renewed high-resolution verification before fabrication or geometry.
w409-group-I01unreviewed · printed
topOfBasePlate.offsetFromBasementScheduleLine
1′6″The distance arrow is printed; sign, baseline, and assignment to each grouped mark require a targeted recheck. This is not an absolute foot elevation.
column-15verified · derived
steelCenter.worldZ
C1→C13 = 22′7″; C13–C15 common perimeter row-56 ft
reused-checked-control. Column row is a drawing-coordinate control; no finite C16 pad is accepted.
column-15unreviewed · inferred
steelCenter.worldX
UnresolvedNumeric value unresolved
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
column-15unreviewed · inferred
steelCenter.projectiveTraceWorldX
sampled master pixel [1134,578]-49.315058 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
column-15unreviewed · observed
steelCenter.worldZ
same ruled steel-column row through C13, C14, C15-56 ft
Selected-region review only. Signed pad offsets and missing column stations remain unresolved; no finite world placement authorized.
IMG_1328 · Locate on drawing ↗Drawing notation: same ruled steel-column row through C13, C14, C15
selected plan crop, single reader; bounded C13–C15 gate, not an accepted world box.
Calculated from: gate-c13-c15-f13-column-z