Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
column-1verified · derived
Page-right coordinate from C1
0 ft0 ft
First-floor plan coordinates only; not yet registered to building west/north axes.
Calculated from: frame-top-column-bays, frame-left-column-bays
column-1verified · derived
Page-down coordinate from C1
0 ft0 ft
First-floor plan coordinates only; not yet registered to building west/north axes.
Calculated from: frame-top-column-bays, frame-left-column-bays
column-1verified · derived
world x
-78.58333333333333 ft (calculated)-78.583333 ft
Arithmetic of verified printed column bays in the shared +X west / +Z north system; no claim of as-built survey precision.
Calculated from: column-1-plan-x, structural-registration-origin-half-span
column-1verified · derived
world z
-78.58333333333333 ft (calculated)-78.583333 ft
Arithmetic of verified printed column bays in the shared +X west / +Z north system; no claim of as-built survey precision.
Calculated from: column-1-plan-y, structural-registration-origin-half-span
column-1unreviewed · traced
world x foundation trace
-78.9018748421338 ft (provisional trace)-78.901875 ft · estimated uncertainty ±2.237222407 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
column-1unreviewed · traced
world z foundation trace
-78.48692792566763 ft (provisional trace)-78.486928 ft · estimated uncertainty ±2.237222407 ft
Candidate support-center location; the prior trace may represent a steel column, concrete pilaster, stub, or entrance support. Member material/type requires the original schedule.
w409-group-E05verified · printed
basePlate.B
B 4444 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-E05verified · printed
basePlate.L
L 4949 in
Shared printed schedule cell. Exact storey applicability and physical endpoints remain unresolved.
w409-group-E05unreviewed · printed
basePlate.T
T 4¾4.75 in
Thickness fraction deserves renewed high-resolution verification before fabrication or geometry.
w409-group-E05unreviewed · printed
topOfBasePlate.offsetFromBasementScheduleLine
1′6″The distance arrow is printed; sign, baseline, and assignment to each grouped mark require a targeted recheck. This is not an absolute foot elevation.
column-4unreviewed · printed
schedule.spliceOffsetAtFourthFloor
2′0″ SPLICE2 ft
Source review: printed-reference; individual-fabrication-level-not-accepted. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4unreviewed · printed
schedule.spliceOffsetAtSixthFloor
2′0″ SPLICE2 ft
Source review: printed-reference; individual-fabrication-level-not-accepted. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-1verified · printed
schedule.lowerSpliceOffset
3′6″3.5 ft
Source review: checked-master-crop. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4illegible · printed
schedule.topOffset
TOP OF COLS [offset/reference relationship unresolved]Source review: unresolved. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-4unreviewed · printed
channel.section
No channel section has been transcribed from these exterior body cells.Source review: untranscribed; not-evidence-of-absence. Schedule bands are relational; absolute member endpoints and physical cut lengths remain unresolved.
column-1verified · derived
columnCenter.worldX
outer-column centerline square 157′2″; C1 southeast corner-78.583333 ft
Schedule-derived nominal local box only; C1 pad horizontal center, bounds and physical placement withheld.
Calculated from: column-1-registered-world-x
column-1verified · derived
columnCenter.worldZ
outer-column centerline square 157′2″; C1 southeast corner-78.583333 ft
Schedule-derived nominal local box only; C1 pad horizontal center, bounds and physical placement withheld.
Calculated from: column-1-registered-world-z