bway-W403-W404-F4-middle-wall-section-gateverified · observed
Complete wall-section gate
FAIL — no classified interior face or full layer chainW403 directly classifies the exterior stone face for the fourth-/fifth-floor middle span family and W403/W404 agree on the 10-inch column-axis offset and 5-inch encasement-edge witness. Neither sheet supplies a classified interior face, a total exterior-to-interior thickness, or a complete enumerated and dimensioned layer chain. The exact offsets terminate at structural references, not at the missing interior finish boundary.
IMG_1317 · sheet-W403 · Locate on drawing ↗Drawing notation: FACE OF STONE; 10″; C.L. OF COL.; SECTION FOR 13′,14′ AND 15′ SPANS.
Reused from the existing reviewed wall-plane extraction; the source image was not reopened for this gate audit.
IMG_1318 · sheet-W404 · Locate on drawing ↗Drawing notation: FACE OF STONE; 10″; C.L. OF COL.; SECTION THRU 14′ SPANS FROM COL25 TO COL59 ALSO FROM COL26 TO COL70.
The normalized source region is on the upright raw master at rotation 0. The OCR derivative was processed with a 180-degree rotation; no OCR coordinates are used as drawing coordinates here.
IMG_1318 · sheet-W404 · Locate on drawing ↗Drawing notation: FOR SECTIONS OF OUTSIDE WALL BEAMS NOT SHOWN SEE SECTIONS ON 4TH. AND 5TH. FLOORS STRUCTURAL DWG. No.403
Reused from the existing reviewed wall-plane extraction; the source image was not reopened for this gate audit.
bway-W403-W404-F4-middle-wall-section-gateunreviewed · observed
Exterior FACE OF STONE to classified interior finish face
UnresolvedNumeric value unresolved
The exact 10-inch column-axis and 5-inch beam-encasement witnesses do not terminate at an interior wall or finish face and are not wall thicknesses.
IMG_1317 · sheet-W403 · Locate on drawing ↗Drawing notation: FACE OF STONE; 10″; C.L. OF COL.; SECTION FOR 13′,14′ AND 15′ SPANS.
Reused from the existing reviewed wall-plane extraction; the source image was not reopened for this gate audit.
IMG_1318 · sheet-W404 · Locate on drawing ↗Drawing notation: FACE OF STONE; 10″; C.L. OF COL.; SECTION THRU 14′ SPANS FROM COL25 TO COL59 ALSO FROM COL26 TO COL70.
The normalized source region is on the upright raw master at rotation 0. The OCR derivative was processed with a 180-degree rotation; no OCR coordinates are used as drawing coordinates here.
IMG_1318 · sheet-W404 · Locate on drawing ↗Drawing notation: FOR SECTIONS OF OUTSIDE WALL BEAMS NOT SHOWN SEE SECTIONS ON 4TH. AND 5TH. FLOORS STRUCTURAL DWG. No.403
Reused from the existing reviewed wall-plane extraction; the source image was not reopened for this gate audit.
bway-W403-W404-F4-middle-wall-section-gateunreviewed · observed
Classified interior face world X
UnresolvedNumeric value unresolved
The exterior stone-face arithmetic supplies no opposite physical boundary.
IMG_1317 · sheet-W403 · Locate on drawing ↗Drawing notation: FACE OF STONE; 10″; C.L. OF COL.; SECTION FOR 13′,14′ AND 15′ SPANS.
Reused from the existing reviewed wall-plane extraction; the source image was not reopened for this gate audit.
IMG_1318 · sheet-W404 · Locate on drawing ↗Drawing notation: FACE OF STONE; 10″; C.L. OF COL.; SECTION THRU 14′ SPANS FROM COL25 TO COL59 ALSO FROM COL26 TO COL70.
The normalized source region is on the upright raw master at rotation 0. The OCR derivative was processed with a 180-degree rotation; no OCR coordinates are used as drawing coordinates here.
IMG_1318 · sheet-W404 · Locate on drawing ↗Drawing notation: FOR SECTIONS OF OUTSIDE WALL BEAMS NOT SHOWN SEE SECTIONS ON 4TH. AND 5TH. FLOORS STRUCTURAL DWG. No.403
Reused from the existing reviewed wall-plane extraction; the source image was not reopened for this gate audit.