Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
bway-W209-library-window-head-special-conditionverified · printed
Sheet title
DETAIL OF UPPER STORIES — BROADWAY ELEVATIONThis wording establishes Broadway/upper-story scope but not equivalence to W-207.
bway-W209-library-window-head-special-conditionverified · printed
Detail title
SECTION THRU LIBRARY WINDOW HEADThe named library condition is retained and prevents generic propagation.
bway-W209-library-window-head-special-conditionverified · printed
Printed detail scale
SCALE 3/4" = 1'-0"No image-space distance is converted from this scale.
bway-W209-library-window-head-special-conditionverified · printed
Seventh-floor finish elevation
FIN. 7TH FL. EL. 171.75171.75 ft
Broadway/Main-side upper-story datum; it does not place the wall horizontally.
bway-W209-library-window-head-special-conditionverified · observed
Applicability to generic W-207 fourth-floor opening
SECTION THRU LIBRARY WINDOW HEADNot established. Treat as a named special condition until a reviewed cross-reference proves otherwise.
bway-W209-library-window-head-special-conditionunreviewed · observed
Overall exterior-to-interior wall thickness
UnresolvedNumeric value unresolved
Dense local dimensions were not treated as a complete classified layer chain.
bway-W209-library-window-head-special-conditionunreviewed · observed
World X and Broadway bay station
UnresolvedNumeric value unresolved
Column marks and plan correspondence require a dedicated registration pass.
bway-W209-library-window-head-special-conditionunreviewed · observed
Masonry/frame/sash/visible opening-boundary correspondence
UnresolvedNot classified in this bounded applicability audit.
bway-W209-library-window-head-special-conditionverified · printed
structural-companion-sheet-reference
SEE STRUCTUAL DWGS SH.415 FOR SIZE & SPACING OF REINFORCING415 sheet-number
Same W209 library head note previously recorded without its identifier. The SH.415 reference is transcribed; companion reinforcement sizes/spacings and authority remain unverified.
IMG_1300 · W-209 · Locate on drawing ↗Drawing notation: SEE STRUCTUAL DWGS SH.415 FOR SIZE & SPACING OF REINFORCING
Same W209 library head note previously recorded without its identifier. The SH.415 reference is transcribed; companion reinforcement sizes/spacings and authority remain unverified.
bway-W209-library-window-head-special-conditionverified · printed
structural-reinforcement-instruction
FOR SIZE & SPACING OF REINFORCINGPrinted source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.
IMG_1300 · W-209 · Locate on drawing ↗Drawing notation: FOR SIZE & SPACING OF REINFORCING
Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.
bway-W209-library-window-head-special-conditionunreviewed · printed
structural-companion-identifier-unresolved
SEE STRUCTURAL DWGS [identifier not certified]Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.
IMG_1300 · W-209 · Locate on drawing ↗Drawing notation: SEE STRUCTURAL DWGS [identifier not certified]
Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.
bway-W209-library-window-head-special-conditionverified · printed
wood-label
WOODPrinted source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.
IMG_1300 · W-209 · Locate on drawing ↗Drawing notation: WOOD
Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.
bway-W209-library-window-head-special-conditionverified · printed
library-head-channel-nominal-designation
12″ C12 in
Printed channel designation in library window-head structural section; nominal size only, not overall wall thickness or a closed channel profile.
IMG_1300 · W-209 · Locate on drawing ↗Drawing notation: 12″ C
Printed channel designation in library window-head structural section; nominal size only, not overall wall thickness or a closed channel profile.
bway-W209-library-window-head-special-conditionverified · printed
library-head-local-vertical-witness
3′-0″36 in
Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.
IMG_1300 · W-209 · Locate on drawing ↗Drawing notation: 3′-0″
Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.
bway-W209-library-window-head-special-conditionverified · printed
library-detail-seventh-floor-datum-token
FIN. 7TH FLOOR ELEV. 173.75173.75 unlabeled-datum
Library-head detail's own right-hand seventh-floor datum token, visually confirmed in a second enlarged crop. Prior bway-W209-seventh-floor-line 171.75 has a different source box [0.55,0.45,0.77,0.75], at the main wall section. Preserve distinct witnesses; do not withdraw or select a governing datum. The printed token has no adjacent explicit unit.
IMG_1300 · W-209 · Locate on drawing ↗Drawing notation: FIN. 7TH FLOOR ELEV. 173.75
Library-head detail's own right-hand seventh-floor datum token, visually confirmed in a second enlarged crop. Prior bway-W209-seventh-floor-line 171.75 has a different source box [0.55,0.45,0.77,0.75], at the main wall section. Preserve distinct witnesses; do not withdraw or select a governing datum. The printed token has no adjacent explicit unit.
Conflicting readings: bway-W209-seventh-floor-line