Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
b-stair-aunreviewed · traced
Boundary vertex 1 · west
-79.8687 ft (trace)-79.8687 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
Calculated from: b-stair-a-footprint-trace
b-stair-aunreviewed · traced
Boundary vertex 1 · north
52.4786 ft (trace)52.4786 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
Calculated from: b-stair-a-footprint-trace
b-stair-aunreviewed · traced
Boundary vertex 2 · west
-72.2383 ft (trace)-72.2383 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
Calculated from: b-stair-a-footprint-trace
b-stair-aunreviewed · traced
Boundary vertex 2 · north
52.5431 ft (trace)52.5431 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
Calculated from: b-stair-a-footprint-trace
b-stair-aunreviewed · traced
Boundary vertex 3 · west
-72.1057 ft (trace)-72.1057 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
Calculated from: b-stair-a-footprint-trace
b-stair-aunreviewed · traced
Boundary vertex 3 · north
57.099 ft (trace)57.099 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
Calculated from: b-stair-a-footprint-trace
b-stair-aunreviewed · traced
Boundary vertex 4 · west
-62.3795 ft (trace)-62.3795 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
Calculated from: b-stair-a-footprint-trace
b-stair-aunreviewed · traced
Boundary vertex 4 · north
57.1818 ft (trace)57.1818 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
Calculated from: b-stair-a-footprint-trace
b-stair-aunreviewed · traced
Boundary vertex 5 · west
-62.2702 ft (trace)-62.2702 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
Calculated from: b-stair-a-footprint-trace
b-stair-aunreviewed · traced
Boundary vertex 5 · north
62.0326 ft (trace)62.0326 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
Calculated from: b-stair-a-footprint-trace
b-stair-aunreviewed · traced
Boundary vertex 6 · west
-79.5464 ft (trace)-79.5464 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
Calculated from: b-stair-a-footprint-trace
b-stair-aunreviewed · traced
Boundary vertex 6 · north
61.8843 ft (trace)61.8843 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
Calculated from: b-stair-a-footprint-trace
b-stair-aillegible · observed
clear-height
Not readNumeric value unresolved
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
b-stair-averified · printed
up-riser-count
UP22R22 count
Visible marked flight only; do not infer tread, riser height or connected level from count.
IMG_1200 · Locate on drawing ↗Drawing notation: STAIR A
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.