Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
b-door-22-corridorunreviewed · traced
Opening endpoint 1 · west
60.6437 ft (trace)60.6437 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: Visible door leaf and swing
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
b-door-22-corridorunreviewed · traced
Opening endpoint 1 · north
33.1761 ft (trace)33.1761 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: Visible door leaf and swing
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
b-door-22-corridorunreviewed · traced
Opening endpoint 2 · west
60.4313 ft (trace)60.4313 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: Visible door leaf and swing
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
b-door-22-corridorunreviewed · traced
Opening endpoint 2 · north
36.7287 ft (trace)36.7287 ft · estimated uncertainty ±3 ft
IMG_1200 · Locate on drawing ↗Drawing notation: Visible door leaf and swing
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
b-door-22-corridorunreviewed · derived
Traced opening width
3.559 ft (not a printed door size)3.559 ft · estimated uncertainty ±1.25 ft
IMG_1200 · Locate on drawing ↗Drawing notation: Visible door leaf and swing
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
Calculated from: b-door-22-corridor-jamb-1-west, b-door-22-corridor-jamb-1-north, b-door-22-corridor-jamb-2-west, b-door-22-corridor-jamb-2-north
b-door-22-corridorunreviewed · observed
height
UnresolvedNumeric value unresolved
IMG_1200 · Locate on drawing ↗Drawing notation: Visible door leaf and swing
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
b-door-22-corridorunreviewed · observed
sill
UnresolvedNumeric value unresolved
IMG_1200 · Locate on drawing ↗Drawing notation: Visible door leaf and swing
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
b-door-22-corridorunreviewed · observed
printed-width
UnresolvedNumeric value unresolved
IMG_1200 · Locate on drawing ↗Drawing notation: Visible door leaf and swing
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.
b-door-22-corridorunreviewed · traced
opening-width-trace
Width from provisional traced jamb interval3.559 ft · estimated uncertainty ±1.25 ft
IMG_1200 · Locate on drawing ↗Drawing notation: Visible door leaf and swing
Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.