assembly-broadway-F4-middle-exterior-wall-candidateunreviewed · observed
Classified interior finish-face world X
UnresolvedNumeric value unresolved
analytical source overlay and provisional candidate references only
IMG_1317 · sheet-W403 · Locate on drawing ↗Drawing notation: FACE OF STONE; 10"; C.L. OF COL.; SECTION FOR 13',14' AND 15' SPANS
Direct fourth-/fifth-floor middle structural span control, reused from the existing audited package; image not reopened.
assembly-broadway-F4-middle-exterior-wall-candidateunreviewed · observed
Stone backing and intermediate layer thicknesses
UnresolvedNumeric value unresolved
analytical source overlay and provisional candidate references only
IMG_1317 · sheet-W403 · Locate on drawing ↗Drawing notation: FACE OF STONE; 10"; C.L. OF COL.; SECTION FOR 13',14' AND 15' SPANS
Direct fourth-/fifth-floor middle structural span control, reused from the existing audited package; image not reopened.
assembly-broadway-F4-middle-exterior-wall-candidateunreviewed · observed
Exterior stone to interior finish total depth
UnresolvedNumeric value unresolved
analytical source overlay and provisional candidate references only
IMG_1317 · sheet-W403 · Locate on drawing ↗Drawing notation: FACE OF STONE; 10"; C.L. OF COL.; SECTION FOR 13',14' AND 15' SPANS
Direct fourth-/fifth-floor middle structural span control, reused from the existing audited package; image not reopened.
assembly-broadway-F4-middle-exterior-wall-candidateverified · observed
Physical wall and opening pilot authorization
FAIL — no continuous exterior-to-interior wall chainThe W207 Section C-C local returns differ by 1 1/2 inches; their differing endpoint conditions and bay assignment prohibit a single generic reveal depth. W207 Section C-C does not supply a dimension from its exterior stone face to a classified interior finish face; its 3-inch T.C. tile cannot be added to the W403 face-to-column-axis control because the references are not chained. W-6 fourth-floor plan has an observed west room-side wall/finish trace, but its exterior stone face and world registration are null. It cannot close this face chain. Both the earlier W-6/W207 4/11-to-B02 placement and the subsequent ordinal B02 identity are retracted. The page-right W-6 crop verifies the printed 4/11 key and its match to W207, but the oriented plan places it near Madison/south rather than B02 near Main/north. B09 is a diagnostic station candidate only; no metric placement, wall host or room-side face is accepted.
IMG_1317 · sheet-W403 · Locate on drawing ↗Drawing notation: FACE OF STONE; 10"; C.L. OF COL.; SECTION FOR 13',14' AND 15' SPANS
Direct fourth-/fifth-floor middle structural span control, reused from the existing audited package; image not reopened.