Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
stair-w228-bde-rail-profile-registerillegible · printed
lower_isolated_string_profile_right_trim_fraction_unresolved
[small right fraction]″Numeric value unresolved
Lower profile narrow right return fraction not certified. Do not select a gauge or borrow a neighboring profile fraction.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: [small right fraction]″
Lower profile narrow right return fraction not certified. Do not select a gauge or borrow a neighboring profile fraction.
Calculated from: stairbuild1013f-img_1265-m028
stair-w228-bde-rail-profile-registerverified · observed
single_tread_support_depicted_circular_joint_positions
[two open circular joint symbols beneath selected horizontal tread support]2 count
Two circular symbols beneath one selected horizontal tread support are depicted type joint positions only. Symbols do not establish bolt/screw type, diameter, pitch, material, substrate, anchorage or installed count.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: [two open circular joint symbols beneath selected horizontal tread support]
Two circular symbols beneath one selected horizontal tread support are depicted type joint positions only. Symbols do not establish bolt/screw type, diameter, pitch, material, substrate, anchorage or installed count.
stair-w228-bde-rail-profile-registerverified · observed
single_riser_support_depicted_circular_joint_positions
[two open circular joint symbols on selected vertical riser support]2 count
Two circular symbols on selected vertical support above landing are depicted type positions only. No size, metal gauge, fastener type or installation quantity established.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: [two open circular joint symbols on selected vertical riser support]
Two circular symbols on selected vertical support above landing are depicted type positions only. No size, metal gauge, fastener type or installation quantity established.
stair-w228-bde-rail-profile-registerverified · printed
newel_square_nominal_side
4″ SQ NEWEL4 in
Same lower B/D/E newel square leader as prior non-null candidate, original white drawing layer. Nominal square source section only; tubing wall, cast cap, installed quantities and neighboring handrail dimensions separate.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: 4″ SQ NEWEL
Same lower B/D/E newel square leader as prior non-null candidate, original white drawing layer. Nominal square source section only; tubing wall, cast cap, installed quantities and neighboring handrail dimensions separate.
stair-w228-bde-rail-profile-registerverified · printed
upper_isolated_string_profile_left_offset_resolution
1¼″1.25 in
Original white drawing layer, upper isolated string profile immediately below the inclined B/D/E panel. Correct125-degree clockwise crop shows left segment before10in body as1¼in. Separate from lower isolated profile1½in and narrow outer/trim segments. Whole crop rectangle is provenance, not trace or complete profile acceptance.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: 1¼″
Original white drawing layer, upper isolated string profile immediately below the inclined B/D/E panel. Correct125-degree clockwise crop shows left segment before10in body as1¼in. Separate from lower isolated profile1½in and narrow outer/trim segments. Whole crop rectangle is provenance, not trace or complete profile acceptance.