An identified object is not a fully modeled object. Missing dimensions, locations and relationships remain explicit.
stair · f3-stair-dModeling: not-modeled
STAIR D
Research representation: boundary trace. Architectural checks: pending.
Third floor · Original mark: D
Existing identity augmented only.
Source relationships · not a verified physical connection
37 recorded properties
Still to extract or check- Exact clear dimensions
- Wall/assembly thickness
- Ceiling height
- Complete door/window instance inventory
- Finish and fixture detail
- Exact floor opening
- Landing elevations
- Tread/riser dimensions
- Headroom
- Accepted horizontal insertion origin
- Precise W224 wall-reference endpoints
- World host wall and door jamb interfaces
- Exact wall-reference face correction
- Accepted interior support coordinates
- Accepted insertion origin
Inspect this object’s readings →View source IMG_1211 ↗
opening · f3-door-stair-dModeling: not-modeled
stair-d threshold
Research representation: boundary trace. Architectural checks: pending.
Third floor
Existing identity augmented only.
Source relationships · not a verified physical connection
18 recorded properties · Room assignment not established
Still to extract or check- Exact host-wall ID and jamb station
- Printed width and height
- Sill/head elevation
- Door type and hardware
- Nominal-to-rough opening relationship
- Door/frame type
- Jamb station
- Sill/threshold build-up
- Accepted host geometry
Inspect this object’s readings →View source IMG_1211 ↗
type · stair-d-w224-typical-typeModeling: not-modeled
Stair D W224 typical-floor unplaced type
Research representation: none. Architectural checks: pending.
Third floor · Fourth floor · Fifth floor · Original mark: D
New finish/construction observations augment the existing type without assigning a world placement.
Source relationships · not a verified physical connection
40 recorded properties
Still to extract or check- Printed individual riser height / equal-riser confirmation
- Construction thicknesses
- Railing/newel dimensions and spacing
- Exact world placement
- Sixth-floor variant
- Fan-room and roof stairs
- Companion W228 complete review
- Exact finish and wall-string projection dimensions
- Tread/landing product and thickness
- Complete W228 profile extraction
Inspect this object’s readings →View source IMG_1114 ↗
wall · f3-wall-stair-d-entryModeling: not-modeled
Stair D entry partition — analytical host candidate
Research representation: none. Architectural checks: pending.
Third floor
Analytical host identity only; no accepted line, solid or historical wall mark.
5 recorded properties
Still to extract or check- Rough versus finish reference lines
- Finished assembly thickness
- World endpoints, base and top
- Door/jamb interfaces
Inspect this object’s readings →View source IMG_1114 ↗
assembly · stair-w228-typical-detail-registerModeling: not-modeled
W228 building-wide typical stair-detail register
Research representation: none. Architectural checks: pending.
Basement · First floor · Second floor · Third floor · Fourth floor · Fifth floor · Sixth floor · Seventh floor · Eighth floor · Original mark: W228
Reusable local construction details. W228 identifies applicability but does not provide member lengths or source-to-building insertion transforms.
14 recorded properties
Still to extract or check- Complete fabrication transcription
- Storey exceptions
- Member lengths
- Building insertion transforms
Inspect this object’s readings →View source IMG_1122 ↗
section · stair-w228-bde-landing-riser-sectionModeling: not-modeled
W228 typical landing and riser section for Stairs B, D and E
Research representation: none. Architectural checks: pending.
Basement · First floor · Second floor · Third floor · Fourth floor · Fifth floor · Sixth floor · Seventh floor · Eighth floor
Reusable source-local construction section explicitly captioned for Stairs B, D and E.
Source relationships · not a verified physical connection
2 recorded properties
Still to extract or check- Complete gauges
- Fasteners
- Welds
- Member lengths
- Storey exceptions
- Building placement
Inspect this object’s readings →View source IMG_1122 ↗
section · stair-w228-stair-e-floor-newel-sectionModeling: not-modeled
W228 Stair E newel-post section at floor level
Research representation: none. Architectural checks: pending.
First floor · Second floor · Third floor · Fourth floor · Fifth floor · Sixth floor · Seventh floor · Eighth floor
Reusable source-local section explicitly captioned for Stair E; exact storey exceptions remain unresolved.
Source relationships · not a verified physical connection
1 recorded properties
Still to extract or check- Complete dimension chain
- Newel profile
- Connections
- Member lengths
- Building placement
Inspect this object’s readings →View source IMG_1122 ↗
section · stair-w228-bde-landing-newel-sectionModeling: not-modeled
W228 newel-post section at landings for Stairs B, D and E
Research representation: none. Architectural checks: pending.
Basement · First floor · Second floor · Third floor · Fourth floor · Fifth floor · Sixth floor · Seventh floor · Eighth floor
Reusable source-local landing section showing a 12-inch channel and newel interface.
Source relationships · not a verified physical connection
1 recorded properties
Still to extract or check- Channel length
- Connection plates
- Fasteners
- Newel profile
- Building placement
Inspect this object’s readings →View source IMG_1122 ↗
section · stair-w228-bde-floor-newel-sectionModeling: not-modeled
W228 newel-post section at floor levels for Stairs B, D and E
Research representation: none. Architectural checks: pending.
First floor · Second floor · Third floor · Fourth floor · Fifth floor · Sixth floor · Seventh floor · Eighth floor
Reusable source-local floor-level section showing terrazzo floor, marble base, a 6-inch channel and soffit relationship.
Source relationships · not a verified physical connection
2 recorded properties
Still to extract or check- Finish thicknesses
- Channel length
- Connection plates
- Fasteners
- Soffit build-up
- Building placement
Inspect this object’s readings →View source IMG_1122 ↗
assembly · stair-w228-two-riser-landing-conditionModeling: not-modeled
W228 landing condition with two risers in the landing
Research representation: none. Architectural checks: pending.
First floor · Second floor · Third floor · Fourth floor · Fifth floor · Sixth floor · Seventh floor · Eighth floor
Reusable local section/elevation pair. It is a candidate explanation for the W226 sixth-to-seventh 20-versus-22 riser readings, but W228 does not identify the applicable Stair E storey in this detail.
Source relationships · not a verified physical connection
5 recorded properties
Still to extract or check- Applicable stairs/storeys
- Exact riser heights
- Complete plate/channel connection
- Newel interface
- Building placement
Inspect this object’s readings →View source IMG_1122 ↗
fitting · stair-w228-replaceable-safety-treadModeling: not-modeled
W228 replaceable safety tread
Research representation: none. Architectural checks: pending.
Basement · First floor · Second floor · Third floor · Fourth floor · Fifth floor · Sixth floor · Seventh floor · Eighth floor
Called out on the B/D/E landing-and-riser section; material/profile and applicable storeys require the W228 schedule notes.
Source relationships · not a verified physical connection
1 recorded properties
Still to extract or check- Material
- Profile
- Width/depth
- Fasteners
- Applicable storeys
- Building placement
Inspect this object’s readings →View source IMG_1122 ↗
fitting · stair-w228-panelled-riserModeling: not-modeled
W228 panelled riser
Research representation: none. Architectural checks: pending.
Basement · First floor · Second floor · Third floor · Fourth floor · Fifth floor · Sixth floor · Seventh floor · Eighth floor
Called out on the B/D/E landing-and-riser section.
Source relationships · not a verified physical connection
1 recorded properties
Still to extract or check- Material
- Panel profile
- Thickness
- Joints
- Fasteners
- Building placement
Inspect this object’s readings →View source IMG_1122 ↗
assembly · stair-w228-extended-wall-string-baseModeling: not-modeled
W228 landing base formed by extended wall string
Research representation: none. Architectural checks: pending.
Basement · First floor · Second floor · Third floor · Fourth floor · Fifth floor · Sixth floor · Seventh floor · Eighth floor
B/D/E section shows the wall string extending to form the landing base.
Source relationships · not a verified physical connection
1 recorded properties
Still to extract or check- String profile
- Thickness
- End geometry
- Connections
- Building placement
Inspect this object’s readings →View source IMG_1122 ↗
fitting · stair-w228-wall-handrail-bracketModeling: not-modeled
W228 wall handrail and bracket
Research representation: none. Architectural checks: pending.
Basement · First floor · Second floor · Third floor · Fourth floor · Fifth floor · Sixth floor · Seventh floor · Eighth floor
Generic W228 handrail/bracket detail; material varies by stair and storey according to the sheet note.
Source relationships · not a verified physical connection
8 recorded properties
Still to extract or check- Stair E material assignment
- Rail profile
- Bracket fabrication
- Anchorage
- Run lengths
- Building placement
Inspect this object’s readings →View source IMG_1122 ↗
assembly · stair-e-upper-diagnostic-envelopeModeling: not-modeled
Stair E upper-story median diagnostic envelope
Research representation: none. Architectural checks: pending.
Second floor · Third floor · Fourth floor · Fifth floor · Sixth floor · Seventh floor · Eighth floor · Original mark: E
Median of the level-2, level-3, level-5, level-6 and level-7 provisional Stair E plan-envelope extents. Level 4 is excluded because its MEP-underlay trace has 5-foot uncertainty; level 1 and level 8 are terminal/special envelopes rather than the repeated upper-story condition.
Source relationships · not a verified physical connection
10 recorded properties
Still to extract or check- Accepted building transform
- Exact enclosure faces
- Exact floor openings
- Floor-specific exceptions
- Landing construction
- Headroom
- Physical wall, stair and railing geometry
Inspect this object’s readings →View source IMG_1207 ↗
stair · f6-f7-stair-e-upper-diagnostic-placementModeling: analytical-preview
Stair E level 6 to regional level 7 diagnostic
Research representation: provisional surface. Architectural checks: pending.
Sixth floor · Seventh floor · Original mark: E
Candidate diagnostic with twenty ordinary flight risers plus the W228 two-riser landing condition, reaching W226's regional seventh-floor datum at local 80 feet.
Source relationships · not a verified physical connection
3 recorded properties
Still to extract or check- Accepted placement
- Proof that W228 two-riser condition applies here
- Exact clear width
- Landing dimensions
- Tread/riser profiles
- Stringers
- Rails
- Headroom
- Slab openings
- Transition to the generic level-7 floor plane
Inspect this object’s readings →View source IMG_1118 ↗
stair · f7-f8-stair-e-upper-diagnostic-placementModeling: analytical-preview
Stair E regional level 7 to level 8 diagnostic
Research representation: provisional surface. Architectural checks: pending.
Seventh floor · Eighth floor · Original mark: E
Two ten-riser switchback flights from W226's regional seventh-floor datum at local 80 feet to the eighth floor at local 92 feet.
Source relationships · not a verified physical connection
2 recorded properties
Still to extract or check- Accepted placement
- Exact clear width
- Landing dimensions
- Tread/riser profiles
- Stringers
- Rails
- Headroom
- Slab openings
- Transition from the generic level-7 floor plane
Inspect this object’s readings →View source IMG_1118 ↗
assembly · f4-f5-stair-e-physical-intermediate-landing-candidateModeling: not-modeled
f4 f5 stair e physical intermediate landing candidate
Research representation: none. Architectural checks: pending.
Fourth floor · Fifth floor · Original mark: METAL LANDING
1 recorded properties
Still to extract or check- closed landing polygon and dimension chain
- finished top elevation and construction thickness
- wall-string and support connections
- accepted X/Z placement and joined flight boundaries
Inspect this object’s readings →View source IMG_1118 ↗
assembly · closure1011z-w228-ac-window-sectionModeling: not-modeled
W228 typical section at window for Stairs A and C
Research representation: none. Architectural checks: pending.
Floor assignment pending · Original mark: A & C
7 recorded properties
Still to extract or check- Channel section series and weight
- Plate-string metal specification and gauge standard
- All connection rivet/bolt/weld sizes
- Marble and steel profiles, member lengths and window registration
- Stair/storey installation exceptions
Inspect this object’s readings →View source IMG_1265 ↗
assembly · detail-w228-staira-c-upper-left-constructionModeling: not-modeled
W228 upper-left typical construction for Stair A basement–second and Stair C first–second
Research representation: none. Architectural checks: pending.
Basement · First floor · Second floor
10 recorded properties
Still to extract or check- Complete fractional dimensions and witness endpoint classification
- Installed instance registration and component quantities
- Companion details and handwritten revision reconciliation
- Independent modeling and checks
Inspect this object’s readings →View source IMG_1265 ↗
assembly · stair-w228-bde-rail-profile-registerModeling: not-modeled
W228 B/D/E typical flight and landing rail/newel witnesses
Research representation: none. Architectural checks: pending.
Floor assignment pending · Original mark: B, D, E
45 recorded properties
Still to extract or check- Precisely classified rail-height witness endpoints
- Tube fraction, wall thickness and material specification
- Post spacing, member extents, connections and floor exceptions
- Full fine dimension chains and witness endpoint classes
- Source-to-building registration, slab openings and installed instances
- Companion details, revision authority and independent physical checks
Inspect this object’s readings →View source IMG_1122 ↗
assembly · stair-w228-fgh-floor-profile-registerModeling: not-modeled
W228 F/G seventh-floor and H first-floor profile
Research representation: none. Architectural checks: pending.
Seventh floor · First floor · Original mark: F & G / H
5 recorded properties
Still to extract or check- Upper profile width, thickness and fasteners absent/clipped in this photo
- Independent F/G installation registration; H first-floor exception
- Full fine dimension chains and witness endpoint classes
- Source-to-building registration, slab openings and installed instances
- Companion details, revision authority and independent physical checks
Inspect this object’s readings →View source IMG_1123 ↗