An identified object is not a fully modeled object. Missing dimensions, locations and relationships remain explicit.
type · type-w409-c4-b2-angle-profileModeling: not-modeled
type w409 c4 b2 angle profile
Research representation: none. Architectural checks: pending.
Floor assignment pending
3 recorded properties
Still to extract or check- Length and physical endpoints
- Local assembly translation/rotation
- Global orientation
- Material grade
- Rolled fillet radii
Inspect this object’s readings →View source IMG_1323 ↗
type · type-w409-c4-b2-plate-profileModeling: not-modeled
type w409 c4 b2 plate profile
Research representation: none. Architectural checks: pending.
Floor assignment pending
2 recorded properties
Still to extract or check- Length and physical endpoints
- Local assembly translation/rotation
- Global orientation
- Material grade
Inspect this object’s readings →View source IMG_1323 ↗
type · type-w409-c4-b3-angle-profileModeling: not-modeled
type w409 c4 b3 angle profile
Research representation: none. Architectural checks: pending.
Floor assignment pending
3 recorded properties
Still to extract or check- Length and physical endpoints
- Local assembly translation/rotation
- Global orientation
- Material grade
- Rolled fillet radii
Inspect this object’s readings →View source IMG_1323 ↗
type · type-w409-c4-b3-plate-profileModeling: not-modeled
type w409 c4 b3 plate profile
Research representation: none. Architectural checks: pending.
Floor assignment pending
2 recorded properties
Still to extract or check- Length and physical endpoints
- Local assembly translation/rotation
- Global orientation
- Material grade
Inspect this object’s readings →View source IMG_1323 ↗
type · type-w409-c4-b4-angle-profileModeling: not-modeled
type w409 c4 b4 angle profile
Research representation: none. Architectural checks: pending.
Floor assignment pending
3 recorded properties
Still to extract or check- Length and physical endpoints
- Local assembly translation/rotation
- Global orientation
- Material grade
- Rolled fillet radii
Inspect this object’s readings →View source IMG_1323 ↗
type · type-w409-c4-b4-plate-profileModeling: not-modeled
type w409 c4 b4 plate profile
Research representation: none. Architectural checks: pending.
Floor assignment pending
2 recorded properties
Still to extract or check- Length and physical endpoints
- Local assembly translation/rotation
- Global orientation
- Material grade
Inspect this object’s readings →View source IMG_1323 ↗
type · type-w409-c4-baseplateModeling: not-modeled
type w409 c4 baseplate
Research representation: none. Architectural checks: pending.
Floor assignment pending
6 recorded properties
Still to extract or check- Thickness fraction
- Column-to-base-plate center offset E′
- Plan rotation
- Anchor holes/bolts
- Grout and stiffener connections
- Bottom elevation
Inspect this object’s readings →View source IMG_1323 ↗
assembly · foundation-main-1-padModeling: not-modeled
pad · 1
Research representation: none. Architectural checks: pending.
Basement · Original mark: 1
Source relationships · not a verified physical connection
26 recorded properties
Still to extract or check- World center and eccentricity vector
- Global section orientation
- Connection to adjacent foundation components
Inspect this object’s readings →View source IMG_1328 ↗
assembly · foundation-main-3-padModeling: not-modeled
pad · 3
Research representation: none. Architectural checks: pending.
Basement · Original mark: 3
Source relationships · not a verified physical connection
18 recorded properties
Still to extract or check- World center and eccentricity vector
- Global section orientation
- Connection to adjacent foundation components
Inspect this object’s readings →View source IMG_1328 ↗
assembly · foundation-main-4-padModeling: not-modeled
pad · 4
Research representation: nominal envelope. Architectural checks: pending.
Basement · Original mark: 4
Source relationships · not a verified physical connection
21 recorded properties
Still to extract or check- Detailed section profile
- Reinforcement
- Independent placement check
- Cap/base connection and vertical stacking
Inspect this object’s readings →View source IMG_1328 ↗
assembly · foundation-main-5-padModeling: not-modeled
pad · 5
Research representation: nominal envelope. Architectural checks: pending.
Basement · Original mark: 5
Source relationships · not a verified physical connection
23 recorded properties
Still to extract or check- Detailed section profile
- Reinforcement
- Independent placement check
- Cap/base connection and vertical stacking
- Independent metric reconciliation of scheduled size with plan silhouette
Inspect this object’s readings →View source IMG_1328 ↗
assembly · foundation-main-8-padModeling: not-modeled
pad · 8
Research representation: none. Architectural checks: pending.
Basement · Original mark: 8
Source relationships · not a verified physical connection
13 recorded properties
Still to extract or check- World center and eccentricity vector
- Global section orientation
- Connection to adjacent foundation components
- footing size · length
Inspect this object’s readings →View source IMG_1328 ↗
assembly · foundation-main-9-padModeling: not-modeled
pad · 9
Research representation: none. Architectural checks: pending.
Basement · Original mark: 9
Source relationships · not a verified physical connection
13 recorded properties
Still to extract or check- World center and eccentricity vector
- Global section orientation
- Connection to adjacent foundation components
- footing size · length
Inspect this object’s readings →View source IMG_1328 ↗
assembly · foundation-main-12-padModeling: not-modeled
pad · 12
Research representation: none. Architectural checks: pending.
Basement · Original mark: 12
Source relationships · not a verified physical connection
14 recorded properties
Still to extract or check- World center and eccentricity vector
- Global section orientation
- Connection to adjacent foundation components
Inspect this object’s readings →View source IMG_1328 ↗
assembly · foundation-main-13-padModeling: not-modeled
pad · 13
Research representation: none. Architectural checks: pending.
Basement · Original mark: 13
Source relationships · not a verified physical connection
20 recorded properties
Still to extract or check- World center and eccentricity vector
- Global section orientation
- Connection to adjacent foundation components
- C13 pad C.G. minus steel center signed X offset, including its side orientation
- legible C13 footing-bottom elevation
- cap center, thickness and bearing transform
- reinforcement count and bar placement
- independent/as-built check
Inspect this object’s readings →View source IMG_1328 ↗
assembly · foundation-main-14-padModeling: not-modeled
pad · 14
Research representation: none. Architectural checks: pending.
Basement · Original mark: 14
Source relationships · not a verified physical connection
14 recorded properties
Still to extract or check- World center and eccentricity vector
- Global section orientation
- Connection to adjacent foundation components
- printed C14 steel-column world X station or checked dimensioned tie
- C14 pad C.G. minus steel center signed X and Z offsets, including proof of zero on either axis
- applicable eccentricity key or direct pad-center control
- cap center, thickness and bearing transform
- independent/as-built check
Inspect this object’s readings →View source IMG_1328 ↗
assembly · foundation-main-15-padModeling: not-modeled
pad · 15
Research representation: none. Architectural checks: pending.
Basement · Original mark: 15
Source relationships · not a verified physical connection
14 recorded properties
Still to extract or check- World center and eccentricity vector
- Global section orientation
- Connection to adjacent foundation components
- printed C15 steel-column world X station or checked dimensioned tie
- C15 pad C.G. minus steel center signed X and Z offsets, including proof of zero on either axis
- applicable eccentricity key or direct pad-center control
- cap center, thickness and bearing transform
- independent/as-built check
Inspect this object’s readings →View source IMG_1328 ↗
assembly · foundation-main-24-padModeling: not-modeled
pad · 24
Research representation: none. Architectural checks: pending.
Basement · Original mark: 24
Source relationships · not a verified physical connection
33 recorded properties
Still to extract or check- World center and eccentricity vector
- Global section orientation
- Connection to adjacent foundation components
Inspect this object’s readings →View source IMG_1328 ↗
interior-wall-candidate · f4-w6-room-402-corridor-partition-candidateModeling: not-modeled
Room 402 corridor partition · physical pilot
Research representation: none. Architectural checks: pending.
Fourth floor · Original mark: 402
28 recorded properties
Still to extract or check- Source-pick both Room 402-side and corridor-side faces at the same stations, classify finish or construction boundaries, and independently verify the printed 4-inch witness connects those faces.
- Pick the wall's two true terminations at its demising intersections; split it at the door with exact two-jamb coordinates and verify the opening width, head and threshold against a door schedule or detail.
- Close reciprocal Room 402/corridor/Room 443 face and door topology, including more than one check of the 7-foot clear corridor witness.
- Validate the frozen W-6 transform locally for classified physical faces and carry uncertainty into canonical X/Z coordinates.
- Establish the wall's physical base and top from an applicable section, ceiling/slab detail or schedule; the 137.25 finished-floor datum and 11.5-foot story interval alone do not give wall height.
- Assign applicable wall assembly and finish layers, material, rating and quantities from the relevant schedule/details.
Inspect this object’s readings →View source IMG_1212 ↗
assembly · assembly-broadway-F4-C58-C52-exterior-wall-candidateModeling: not-modeled
Broadway fourth-floor C58–C52 exterior wall candidate
Research representation: none. Architectural checks: pending.
Fourth floor
13 recorded properties
Still to extract or check- same-condition exterior stone to classified interior finish face depth and every intervening layer/material
- architecturally classified north/south wall ends, joints and pier returns rather than support-axis stations
- physical wall base/top and slab-edge interfaces rather than finished-floor schedule datums
- independently checked W-6 to Broadway elevation horizontal registration and B05 key/host identity
- masonry versus visible/frame/clear opening bounds, sill, head, jamb returns and reveal depth
- W403 stone-face continuity away from the floor-beam section and across the 14-foot span
Inspect this object’s readings →View source IMG_1317 ↗
datum · level-5Modeling: not-modeled
level-5
Research representation: none. Architectural checks: pending.
Fifth floor
2 recorded properties
Inspect this object’s readings →View source IMG_1323 ↗
schedule-cell · framingwitness1014g-img1323-c4-t-cellModeling: not-modeled
C4 baseplate T source cell
Research representation: none. Architectural checks: pending.
Floor assignment pending
2 recorded properties
Still to extract or check- Numeric glyph is not an accepted physical plate thickness.
- C4 baseplate T glyph read as5¾, but no independent unit convention for the unlabeled B/L/T table was established. Physical T in inches remains unresolved.
- C4 source suffix b is not a world signed footing offset. E′ companion SH.411, seating, column top and plan transforms remain open.
- Complete source-to-instance registration, physical endpoints, installed quantities and revision authority remain unresolved.
- Unreviewed regions, companion sheets, schedules and fine fractions remain open; this package is not exhaustive coverage.
- Material grades, connection capacities, world transforms and independent model/as-built checks remain unestablished.
Inspect this object’s readings →View source IMG_1323 ↗
assembly · structnote1014a-img1323-general-notesModeling: not-modeled
W409 general column fabrication and bearing-plate rules; analytical note assembly
Research representation: none. Architectural checks: pending.
Floor assignment pending
8 recorded properties
Still to extract or check- The milling and cap-symbol source questions resolve; C4 section seating, top, baseplate thickness, signed footing eccentricities and installed column transforms remain open.
- 2 in milling threshold is a condition, not an individual plate thickness. 6 in cover-plate stop remains a beam-relative offset, not an absolute cutoff elevation.
- Complete source-to-instance and endpoint registration remains unresolved.
- Material grades, finishes, connection capacities and as-built checks remain unestablished.
- Unreviewed regions, fine fractions, schedules, companion applicability and revision authority remain open.
Inspect this object’s readings →View source IMG_1323 ↗