An identified object is not a fully modeled object. Missing dimensions, locations and relationships remain explicit.
assembly · stair-e-w225-lower-stories-registerModeling: not-modeled
Stair E · W225 lower-stories register
Research representation: none. Architectural checks: pending.
Basement · First floor · Second floor · Third floor · Fourth floor · Fifth floor · Original mark: E / W225
Architectural-detail register only. Existing floor-plan Stair E traces identify the building core, but W225 has no accepted metric transform to those traces.
6 recorded properties
Still to extract or check- Accepted building transform
- Physical flight geometry
- Exact stair opening
- Complete dimensions
- Headroom
- Support connections
Inspect this object’s readings →View source IMG_1262 ↗
assembly · stair-e-w225-intermediate-landing-typeModeling: not-modeled
Stair E · intermediate landing between first and second floors
Research representation: none. Architectural checks: pending.
First floor · Second floor
Source-local plan on W225; not a registered world polygon.
Source relationships · not a verified physical connection
11 recorded properties
Still to extract or check- Complete plan dimension chain
- Rough/finish faces
- Exact landing elevations
- Building transform
- Slab opening
Inspect this object’s readings →View source IMG_1262 ↗
section · stair-e-w225-section-aaModeling: not-modeled
Stair E · W225 longitudinal Section A-A
Research representation: none. Architectural checks: pending.
Basement · First floor · Second floor · Third floor · Fourth floor · Fifth floor · Original mark: A-A
Source-local architectural section; it establishes flight/landing relationships but not a building X/Z transform.
Source relationships · not a verified physical connection
6 recorded properties
Still to extract or check- Exhaustive dimension transcription
- Flight-by-flight riser counts
- Construction thicknesses
- Building transform
Inspect this object’s readings →View source IMG_1262 ↗
section · stair-e-w225-section-bbModeling: not-modeled
Stair E · W225 transverse Section B-B
Research representation: none. Architectural checks: pending.
Basement · First floor · Second floor · Original mark: B-B
Source-local transverse section through the gate and lower flights.
Source relationships · not a verified physical connection
7 recorded properties
Still to extract or check- Complete horizontal chain
- Gate clear opening
- Wall thicknesses
- Building transform
Inspect this object’s readings →View source IMG_1262 ↗
fitting · stair-e-w225-continuous-newelModeling: not-modeled
Stair E continuous newel
Research representation: none. Architectural checks: pending.
First floor · Second floor · Third floor · Fourth floor · Fifth floor
Called out in W225 plan/section; exact profile and every storey extent remain unresolved.
Source relationships · not a verified physical connection
1 recorded properties
Still to extract or check- Section/profile
- Anchorage
- Exact extent
- Storey-by-storey exceptions
- Building placement
Inspect this object’s readings →View source IMG_1262 ↗
fitting · stair-e-w225-metal-railingModeling: not-modeled
Stair E metal railing system
Research representation: none. Architectural checks: pending.
Basement · First floor · Second floor · Third floor · Fourth floor · Fifth floor
Repeated railing callouts and dedicated detail on W225; member geometry is not yet authoring-eligible.
Source relationships · not a verified physical connection
1 recorded properties
Still to extract or check- Member sizes
- Post spacing
- Handrail height/profile
- Connections
- Exact run lengths
- Building placement
Inspect this object’s readings →View source IMG_1262 ↗
opening · stair-e-w225-folding-gateModeling: not-modeled
Stair E folding/lift gate assembly
Research representation: none. Architectural checks: pending.
First floor · Second floor
Gate is shown in Section B-B and in a dedicated local detail; no physical opening is authored.
Source relationships · not a verified physical connection
6 recorded properties · Room assignment not established
Still to extract or check- Clear width
- Height
- Leaf/link count
- Track
- Hardware
- Jambs
- Accepted placement
Inspect this object’s readings →View source IMG_1262 ↗
finish · stair-e-w225-plaster-soffitModeling: not-modeled
Stair E plaster soffit
Research representation: none. Architectural checks: pending.
First floor · Second floor · Third floor · Fourth floor · Fifth floor
Called out below upper flights in Section A-A.
Source relationships · not a verified physical connection
1 recorded properties
Still to extract or check- Thickness
- Substrate
- Edges/joints
- Extent
- Accepted placement
Inspect this object’s readings →View source IMG_1262 ↗
finish · stair-e-w225-basement-tile-wallModeling: not-modeled
Stair E tile wall under basement stair
Research representation: none. Architectural checks: pending.
Basement · First floor
Section A-A identifies a tile wall below the lower run.
Source relationships · not a verified physical connection
1 recorded properties
Still to extract or check- Tile type
- Wall construction
- Height
- Thickness
- Exact endpoints
- Accepted placement
Inspect this object’s readings →View source IMG_1262 ↗
fixture · stair-e-w225-handrail-beam-braceModeling: not-modeled
Stair E handrail brace at beam
Research representation: none. Architectural checks: pending.
First floor · Second floor
Section A-A calls for a handrail brace at a beam along the first-to-second stair assembly; exact occurrence and attachment geometry remain unresolved.
Source relationships · not a verified physical connection
1 recorded properties · Room assignment not established
Still to extract or check- Member section
- Fasteners
- Exact beam identity
- Occurrence count
- Accepted placement
Inspect this object’s readings →View source IMG_1262 ↗
finish · stair-e-w225-first-floor-terrazzo-marble-baseModeling: not-modeled
Stair E first-floor terrazzo and marble-base interface
Research representation: none. Architectural checks: pending.
First floor
Section A-A labels the first-floor landing finish interface at the Stair E enclosure.
Source relationships · not a verified physical connection
1 recorded properties
Still to extract or check- Terrazzo mix
- Marble species
- Base profile
- Thicknesses
- Joints
- Exact extents
- Accepted placement
Inspect this object’s readings →View source IMG_1262 ↗
assembly · stair-e-w225-first-floor-flush-wood-blockModeling: not-modeled
Stair E first-floor flush wood block
Research representation: none. Architectural checks: pending.
First floor
Section A-A calls out a flush wood block at the first-floor interface near the lower stair/rail condition.
Source relationships · not a verified physical connection
1 recorded properties
Still to extract or check- Wood species
- Dimensions
- Fasteners
- Exact host
- Accepted placement
Inspect this object’s readings →View source IMG_1262 ↗
assembly · stair-e-w225-basement-unplastered-jointModeling: not-modeled
Stair E basement joint not plastered
Research representation: none. Architectural checks: pending.
Basement · First floor
Section A-A marks a joint below the basement-to-first run as not plastered.
Source relationships · not a verified physical connection
1 recorded properties
Still to extract or check- Joint type
- Length
- Width
- Substrate
- Exact endpoints
- Accepted placement
Inspect this object’s readings →View source IMG_1262 ↗
assembly · stair-e-w225-basement-first-flight-registerModeling: not-modeled
Stair E basement-to-first source-local flight register
Research representation: none. Architectural checks: pending.
Basement · First floor · Original mark: E
22 recorded properties
Still to extract or check- Independent tread/riser recount in companion source
- Riser height and 15-ft versus generic basement-datum reconciliation
- Full fine dimension chains and witness endpoint classes
- Source-to-building registration, slab openings and installed instances
- Companion details, revision authority and independent physical checks
Inspect this object’s readings →View source IMG_1116 ↗