Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1095 · Folder 191

SCREEN DETAILS IN LOBBY — DOORS & END WALLS

Sheet W217

Extraction: Reviewed · extraction partial. Bounded W217 confirmation: Full-sheet title block, Bay P elevator elevation, and the plan note directly below that elevation. Partial entrance-registration review: W217 supplies the separately registered 3-foot-6-inch finished width and 6-foot-9.75-inch finished-floor-to-head height for Elevator No. 1. Bay P directory, paired door, Elevator No. 2 entrance, clock and other glazed door/screen bays. Normalized from an existing text re-audit; this import did not reopen the source image. Partial W217 review: Bay P elevation identity, complete Bay P plan chain and central paired-door plan station. Elevator-front bounded gate: Bay P Elevator 2 plan station, finished entrance segment, and Elevator 1 similar applicability. W3 Main foyer/public lobby screen physical-polygon gate; source group review remains partial. W3 Main foyer/public lobby screen physical-polygon gate; source group review remains partial. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. W217/W218 T/U/V screen vertical/depth gate; targeted regions only. Main/foyer-lobby Bay U screen physical-segment gate; no finite solid authorized. Main/foyer-lobby Bay U screen physical-segment gate; no finite solid authorized. Main/foyer-lobby Bay U screen physical-segment gate; no finite solid authorized. Partial timed visual review: Source-local drawing evidence only; installed quantity, accepted world placement and physical geometry not established. Partial timed visual review: W217 elevator plan and E-E source-local construction notes; no accepted depth or world placement. Partial timed visual review: undefined

Highlighted reading: customer counter modules repeatedly read about 7 feet 6 inches. Existing text re-audit and existing verified elevator package; images not reopened. Bay P directory, paired door, Elevator No. 2 entrance, clock and other glazed door/screen bays

Show every recorded property on this drawing →

Unresolved extraction work
  • Operating clear width and height after door travel
  • Rough opening width and height
  • Sill, threshold and head sections/build-up
  • Individual leaf widths, thicknesses, overlap and travel
  • Outer ornamental-surround dimensions
  • Wall-face assignment and wall thickness
  • Registered world position and orientation
  • Accepted physical host-wall face and thickness
  • Exact entrance depth relative to the W229 clear-hatch edge
  • Rough opening and operating clear width/height
  • Jamb, reveal, frame, sill, threshold and door-leaf construction
  • Complete shaft, cab, guide, pit, overhead and machinery transforms
  • Independent as-built check
  • Complete drawing-note transcription
  • Every dimension and bay placement
  • Detailed hardware/fastener schedule
  • Exact cross-sheet bay correspondence
  • Cross-photo physical deduplication
  • Complete surviving-object inventory
  • Exact dimensions
  • Construction/alteration chronology
  • Condition assessment
  • P-6 component extraction
  • Installed fixture schedule and positions
  • As-built correspondence
  • Fixture finish and glass color
  • All remaining sheet regions and details
  • Accepted physical wall face and wall thickness
  • Rough opening and operating clear dimensions
  • Frame, stile, rail, muntin and trim profiles
  • Glazing thickness and edge treatment
  • Push-bar profiles, lengths and elevations
  • Hardware, threshold, swing and anchorage
  • Directory case depth and physical world transform
  • Elevator entrance host-wall thickness, return geometry, rough opening and physical world transform
  • A readable first-floor W217 Section E or applicable companion section with front and back faces and exact profile/depth dimensions for one named component, plus complete width and height endpoints for that same component.
  • Printed or independently checked panel extents before any ornament panels are given physical sizes; retain panel instances without fabricated dimensions until then.
  • Classified first-floor host wall face, thickness and jamb/reveal/sill/head interfaces tied to named W229 or W230 controls and the corresponding W3 wall or Bay P station.
  • An independent corresponding-face or endpoint residual within a stated tolerance for the chosen physical front, preserving conflicts and W3 trace uncertainty separately.
  • segment-by-segment material and face classes
  • accepted W3-to-detail endpoint/face registration with independent held-out check
  • world XZ footprints and depths for each pier/screen segment
  • six finished jamb X limits on each side plus rough openings and reveals
  • door/head and transom limits
  • checked threshold bottom and finished screen/pier top elevations
  • resolution of the lobby ceiling reading conflict and scope
  • securely dimensioned and registered threshold bottom/top
  • door head and upper glazing bottom/top with clear dimension endpoints
  • finished screen/pier top on both room sides
  • front/back finished face assignments and segment-specific transverse depths
  • accepted W3-to-W217/W218 face/endpoint registration with held-out check
  • physical XZ segment and six finished door-gap polygons
  • classified north/south finished face or axis and world Z control
  • segment-by-segment thickness and joins
  • accepted west/east pier or bay-division edge class
  • finished jamb limits on both faces
  • threshold bottom/top and door head in local Y
  • finished upper screen and pier bounds
  • independent held-out metric registration
  • Fine fractions and complete witness endpoints require targeted high-resolution crops
  • Companion captures, material code and revision authority require reconciliation
  • Installed floor/room registration, exact depths and modeling checks outstanding
  • Remaining W217 details, title/material-code fine print and notes
  • Exact component depths and classified section endpoints
  • Revision and companion reconciliation; accepted physical registration
  • Head/sill depth fractions and front/back endpoint classifications remain unreadable; gauge and section association reused.
  • Installed instance mapping, world placement, companion/revision authority and whole-building acceptance remain unresolved.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

30 matching objects

An identified object is not a fully modeled object. Missing dimensions, locations and relationships remain explicit.

opening · f1-door-elevator-1Modeling: not-modeled

Elevator No. 1 threshold

Research representation: none. Architectural checks: pending.

First floor

Elevator No. 1 page-top side; observed connections: f1-room-sixth-vestibule ↔ f1-elevator-1. Exact host wall remains unresolved.

Source relationships · not a verified physical connection

64 recorded properties · Room assignment not established

Still to extract or check
  • Exact wall instance and jamb station
  • Sill/head elevation
  • Opening type/hardware
  • Clear opening versus door-panel dimension
  • Rough opening
  • Head/sill section
  • Exact jamb stations
  • Operating clear width and height after door travel
  • Rough opening width and height
  • Sill, threshold and head sections/build-up
  • Individual leaf widths, thicknesses, overlap and travel
  • Outer ornamental-surround dimensions
  • Wall-face assignment and wall thickness
  • Registered world position and orientation
  • Accepted physical host-wall face and thickness
  • Exact entrance depth relative to the W229 clear-hatch edge
  • Rough opening and operating clear width/height
  • Jamb, reveal, frame, sill, threshold and door-leaf construction
  • Complete shaft, cab, guide, pit, overhead and machinery transforms
  • Independent as-built check
Inspect this object’s readings →

View source IMG_1202 ↗

opening · f1-door-elevator-2Modeling: not-modeled

Elevator No. 2 threshold

Research representation: none. Architectural checks: pending.

First floor

Elevator No. 2 page-top side; observed connections: f1-room-broadway-foyer ↔ f1-elevator-2. Exact host wall remains unresolved.

Source relationships · not a verified physical connection

52 recorded properties · Room assignment not established

Still to extract or check
  • Exact wall instance and jamb station
  • Sill/head elevation
  • Opening type/hardware
  • Clear opening versus door-panel dimension
  • Rough opening
  • Head/sill section
  • Exact jamb stations
  • Operating clear width and height after door travel
  • Rough opening width and height
  • Sill, threshold and head sections/build-up
  • Individual leaf widths, thicknesses, overlap and travel
  • Outer ornamental-surround dimensions
  • Wall-face assignment and wall thickness
  • Registered world position and orientation
Inspect this object’s readings →

View source IMG_1202 ↗

opening · f1-door-main-foyer-public-eastModeling: not-modeled

Main foyer / public lobby east pair

Research representation: boundary trace. Architectural checks: pending.

First floor

Main foyer page-top wall; observed connections: f1-room-main-foyer ↔ f1-room-public-lobby. Exact host wall remains unresolved.

Source relationships · not a verified physical connection

15 recorded properties · Room assignment not established

Still to extract or check
  • Exact wall instance and jamb station
  • Printed width and height
  • Sill/head elevation
  • Opening type/hardware
Inspect this object’s readings →

View source IMG_1202 ↗

opening · f1-door-main-foyer-public-centerModeling: not-modeled

Main foyer / public lobby center pair

Research representation: boundary trace. Architectural checks: pending.

First floor

Main foyer page-top wall; observed connections: f1-room-main-foyer ↔ f1-room-public-lobby. Exact host wall remains unresolved.

Source relationships · not a verified physical connection

17 recorded properties · Room assignment not established

Still to extract or check
  • Exact wall instance and jamb station
  • Printed width and height
  • Sill/head elevation
  • Opening type/hardware
Inspect this object’s readings →

View source IMG_1202 ↗

opening · f1-door-main-foyer-public-westModeling: not-modeled

Main foyer / public lobby west pair

Research representation: boundary trace. Architectural checks: pending.

First floor

Main foyer page-top wall; observed connections: f1-room-main-foyer ↔ f1-room-public-lobby. Exact host wall remains unresolved.

Source relationships · not a verified physical connection

15 recorded properties · Room assignment not established

Still to extract or check
  • Exact wall instance and jamb station
  • Printed width and height
  • Sill/head elevation
  • Opening type/hardware
Inspect this object’s readings →

View source IMG_1202 ↗

assembly · w3-public-lobby-bay-uModeling: not-modeled

W3 public-lobby bay U

Research representation: none. Architectural checks: pending.

First floor · Original mark: U

Source relationships · not a verified physical connection

22 recorded properties

Still to extract or check
  • Classified boundary faces
  • Plan station
  • Physical wall/opening geometry
  • World placement
Inspect this object’s readings →

View source IMG_1202 ↗

detail · f1-elevator-doors-1-2-w217-detailModeling: not-modeled

W217 first-floor finished entrance detail for Elevators 1 and 2

Research representation: none. Architectural checks: pending.

First floor · Original mark: W217 · ELEVATOR No. 2 · ELEVATOR 1 SIMILAR

Source relationships · not a verified physical connection

16 recorded properties

Still to extract or check
  • Operating clear width and height after door travel
  • Rough opening width and height
  • Sill, threshold and head sections/build-up
  • Individual leaf widths, thicknesses, overlap and travel
  • Outer ornamental-surround dimensions
  • Wall-face assignment and wall thickness
  • Registered world position and orientation
  • leaf count, operating type, direction, travel, overlap, guides and clear-open condition: The elevation shows two graphic door-face fields and a centerline but no equipment-side mechanics or travel diagram.
  • jamb depth, return, projection and section profile: The 6-inch values are elevation face widths only; Section E is not present in the reviewed close-up as readable construction geometry.
  • ornament vector trace, motif identity, thickness, relief depth, repeat pitch and fabrication geometry: The elevation and material callouts establish visible ornament and generic cast construction, not exact three-dimensional ornament.
  • individual panel width, height, frame-layer widths and depth: Only selected offsets are printed. Panel sizes may not be derived from pixels or by subtracting visually symmetric gaps from the finished envelope.
  • application of model 33 or 34 to earlier visually matching panel rows: Visual pattern matching alone does not establish printed model-number applicability.
  • rough opening width, height and construction interfaces: The accepted 3'-6" by 6'-9 3/4" envelope is bounded by finished entrance faces, not rough construction.
  • wall-face assignment, local station, world position and world orientation: No side-chain token was promoted to placement, and no detail-to-plan registration was performed in this package.
Inspect this object’s readings →

View source IMG_1095 ↗

assembly · f1-public-lobby-w217-bay-p-end-wall-assemblyModeling: not-modeled

W217 Bay P lobby end-wall assembly

Research representation: none. Architectural checks: pending.

First floor

22 recorded properties

Still to extract or check
  • Complete physical geometry
  • Accepted world placement
  • Cross-sheet registration
  • Overall Bay P run; report's roughly 24'-10" reading is not promoted to exact
  • Accepted wall placement
  • Minor offsets and ornament profiles
Inspect this object’s readings →

View source IMG_1098 ↗

fitting · f1-public-lobby-w217-bay-p-directoryModeling: not-modeled

W217 Bay P directory

Research representation: none. Architectural checks: pending.

First floor

3 recorded properties

Still to extract or check
  • Complete physical geometry
  • Accepted world placement
  • Cross-sheet registration
  • Exact width; report says about 3'-6"
  • Height and depth
  • Letter-board internal construction
  • Hardware dimensions
Inspect this object’s readings →

View source IMG_1098 ↗

opening · f1-public-lobby-w217-bay-p-elevator-no2-entranceModeling: not-modeled

W217 Bay P Elevator No. 2 entrance

Research representation: none. Architectural checks: pending.

First floor

Source relationships · not a verified physical connection

11 recorded properties · Room f1-room-public-lobby

Still to extract or check
  • Complete physical geometry
  • Accepted physical world placement
  • Cross-sheet registration
  • Operating clear opening
  • Rough opening
  • Leaf travel
Inspect this object’s readings →

View source IMG_1098 ↗

paired-door · f1-public-lobby-w217-bay-p-door-pairModeling: not-modeled

Bay P central paired glazed-metal doors

Research representation: none. Architectural checks: pending.

First floor

Source relationships · not a verified physical connection

33 recorded properties

Still to extract or check
  • Operating clear width and height
  • Rough opening width and height
  • Leaf, stile, rail, muntin, and frame section profiles
  • Glass thickness, treatment, edge condition, and safety classification
  • Push-bar section, diameter, projection, attachment, and exact mounting elevation
  • Hinges, pivots, closers, pulls, locks, latches, stops, and fasteners
  • Threshold material, section, dimensions, anchorage, and floor transition
  • Door swing direction and opening angle
  • Accepted physical world placement
  • Glass thickness
  • Stile/rail profiles
  • Pivot/closer models
  • Threshold section
  • Accepted world transform
Inspect this object’s readings →

View source IMG_1098 ↗

room-assembly · f1-public-lobby-architectural-envelopeModeling: not-modeled

First-floor public postal lobby architectural envelope

Research representation: none. Architectural checks: pending.

First floor

Source relationships · not a verified physical connection

4 recorded properties

Still to extract or check
  • Controlling lobby ceiling height because 18'-3" and 18'-9" readings conflict
  • Accepted wall-bay positions and widths
  • Coffer-panel dimensions and exact motif assignment
  • Cornice and beam profiles
  • As-built deviations and alteration chronology
Inspect this object’s readings →

View source IMG_1202 ↗

assembly-system · f1-public-lobby-postal-wall-systemModeling: not-modeled

Continuous public postal service and lockbox wall system

Research representation: none. Architectural checks: pending.

First floor

Source relationships · not a verified physical connection

1 recorded properties

Still to extract or check
  • Complete bay-by-bay sequence and correspondence between drawing bays and surviving 1983 modules
  • Original installed lockbox and depository quantities
  • Individual box sizes, row/column counts and numbering ranges
  • Module widths, heights, depths and corner-return geometry
  • Exact staff-side casework dimensions
  • As-built phase of plain/infilled panels
Inspect this object’s readings →

View source IMG_1202 ↗

door-screen-assembly · f1-main-foyer-public-lobby-screen-assemblyModeling: not-modeled

Main Street foyer-to-public-lobby transparent door and screen line

Research representation: none. Architectural checks: pending.

First floor

Source relationships · not a verified physical connection
  • connects (observed, unreviewed): FOYER
  • connects (observed, unreviewed): PUBLIC LOBBY

19 recorded properties

Still to extract or check
  • Printed leaf dimensions for this specific W-218 assembly
  • Exact overall screen dimensions
  • Glass/panel assignment in every upper field
  • Hardware models and finishes
  • Accepted world transforms
Inspect this object’s readings →

View source IMG_1099 ↗

wall-clock · f1-public-lobby-w217-bay-p-clockModeling: not-modeled

Bay P wall clock

Research representation: none. Architectural checks: pending.

First floor

0 recorded properties

Still to extract or check
  • Clock diameter
  • Face material and color
  • Movement
  • Mounting depth
  • Correspondence to distant clock-like fitting in HABS 13
Inspect this object’s readings →

View source IMG_1095 ↗

paired-door-type · type-w217-bay-p-glazed-door-pairModeling: not-modeled

W-217 Bay P central paired glazed-metal doors

Research representation: none. Architectural checks: pending.

First floor · Original mark: P

0 recorded properties

Still to extract or check
  • Complete measured geometry
  • Verified installed instances
  • Accepted building placement
  • As-built correspondence
Inspect this object’s readings →

View source IMG_1095 ↗

directory-case-type · type-w217-bay-p-directoryModeling: not-modeled

W-217 Bay P bronze-framed DIRECTORY case

Research representation: none. Architectural checks: pending.

First floor · Original mark: DIRECTORY

0 recorded properties

Still to extract or check
  • Complete measured geometry
  • Verified installed instances
  • Accepted building placement
  • As-built correspondence
Inspect this object’s readings →

View source IMG_1095 ↗

wall-clock-type · type-w217-bay-p-clockModeling: not-modeled

W-217 Bay P wall clock with separate metal Roman numerals and hands

Research representation: none. Architectural checks: pending.

First floor

0 recorded properties

Still to extract or check
  • Complete measured geometry
  • Verified installed instances
  • Accepted building placement
  • As-built correspondence
Inspect this object’s readings →

View source IMG_1095 ↗

assembly-system · postal-workroom-casework-system-unextractedModeling: not-modeled

Postal workroom staff-side casework system — extraction pending

Research representation: none. Architectural checks: pending.

First floor

0 recorded properties

Still to extract or check
  • Measured boundary
  • Complete contents
  • World placement
  • Cross-sheet coordination
Inspect this object’s readings →

View source IMG_1202 ↗

room-zone · registry-box-parcel-post-alcovesModeling: not-modeled

Registry, box and parcel-post alcove group

Research representation: none. Architectural checks: pending.

First floor

0 recorded properties

Still to extract or check
  • Measured boundary
  • Complete contents
  • World placement
  • Cross-sheet coordination
Inspect this object’s readings →

View source IMG_1202 ↗

room-zone · lockbox-zoneModeling: not-modeled

Public lobby lockbox zone

Research representation: none. Architectural checks: pending.

First floor

0 recorded properties

Still to extract or check
  • Measured boundary
  • Complete contents
  • World placement
  • Cross-sheet coordination
Inspect this object’s readings →

View source IMG_1202 ↗

room-zone · staffed-service-and-depository-zoneModeling: not-modeled

Public lobby staffed-service and depository zone

Research representation: none. Architectural checks: pending.

First floor

0 recorded properties

Still to extract or check
  • Measured boundary
  • Complete contents
  • World placement
  • Cross-sheet coordination
Inspect this object’s readings →

View source IMG_1202 ↗

material · material-postal-screen-plate-glassModeling: not-modeled

Plate glass in postal and door-screen assemblies

Research representation: none. Architectural checks: pending.

First floor

1 recorded properties

Still to extract or check
  • Thickness
  • Safety treatment
  • Replacement chronology
  • Exact clear/obscure assignment outside explicitly described details
Inspect this object’s readings →

View source IMG_1090 ↗

dimension-chain · f1-public-lobby-w217-bay-p-plan-controlModeling: not-modeled

W217 Bay P complete plan chain and W3 analytical registration

Research representation: none. Architectural checks: pending.

First floor · Original mark: BAY P

Source relationships · not a verified physical connection

0 recorded properties

Still to extract or check
  • Accepted physical wall face and wall thickness
  • Rough opening and operating clear dimensions
  • Frame, stile, rail, muntin and trim profiles
  • Glazing thickness and edge treatment
  • Push-bar profiles, lengths and elevations
  • Hardware, threshold, swing and anchorage
  • Directory case depth and physical world transform
  • Elevator entrance host-wall thickness, return geometry, rough opening and physical world transform
  • Independent as-built check
Inspect this object’s readings →

View source IMG_1095 ↗

assembly · parallel-img1095-directoryModeling: not-modeled

Bay P directory cabinet

Research representation: none. Architectural checks: pending.

Floor assignment pending · Original mark: P

1 recorded properties

Still to extract or check
  • Fine fractions and complete witness endpoints require targeted high-resolution crops
  • Companion captures, material code and revision authority require reconciliation
  • Installed floor/room registration, exact depths and modeling checks outstanding
Inspect this object’s readings →

View source IMG_1095 ↗

assembly · parallel-img1095-sectionModeling: not-modeled

Bay P Section E-E

Research representation: none. Architectural checks: pending.

Floor assignment pending · Original mark: E-E

1 recorded properties

Still to extract or check
  • Fine fractions and complete witness endpoints require targeted high-resolution crops
  • Companion captures, material code and revision authority require reconciliation
  • Installed floor/room registration, exact depths and modeling checks outstanding
Inspect this object’s readings →

View source IMG_1095 ↗

assembly · closure1011u-img1095-elevator-eeModeling: not-modeled

Elevator entrance Section E-E specimen

Research representation: none. Architectural checks: pending.

Floor assignment pending · Original mark: E-E

4 recorded properties

Still to extract or check
  • All section depths, returns and profile-layer witness endpoints
  • Face-plate gauge system and resulting thickness
  • Head, sill and jamb fabrication and attachment; installed instance registration
Inspect this object’s readings →

View source IMG_1095 ↗

structural-member · closure1011u-img1095-elevator-plan-supportModeling: not-modeled

Continuous support at elevator entrance plan

Research representation: none. Architectural checks: pending.

Floor assignment pending

1 recorded properties

Still to extract or check
  • Member size and section interpretation
  • Anchor type, spacing and complete structural connection detail
  • Plan-to-section and installed structural registration
Inspect this object’s readings →

View source IMG_1095 ↗

View all source photographs →