An identified object is not a fully modeled object. Missing dimensions, locations and relationships remain explicit.
roof-surface · roof-field-mainModeling: not-modeled
Main composition-roof field
Research representation: none. Architectural checks: pending.
Roof
5 recorded properties
Still to extract or check- Global registration
- World position
- Exact horizontal dimensions
- Regional roof slope/level assignment
- Construction/assembly detail
Inspect this object’s readings →View source IMG_1227 ↗
assembly · roof-img1327-typical-slab-detail-01Modeling: not-modeled
Typical roof slab source detail
Research representation: none. Architectural checks: pending.
Roof
5 recorded properties
Still to extract or check- sheet number
- confirmed slab thickness witness
- material specification
- field applicability
- complete build-up
- world footprint
- top and underside elevations
Inspect this object’s readings →View source IMG_1327 ↗
reinforcement · roof-img1327-slab-mesh-01Modeling: not-modeled
Slab mesh shown in typical roof detail
Research representation: none. Architectural checks: pending.
Roof
1 recorded properties
Still to extract or check- complete mesh specification
- gauge
- spacing
- cover
- lap and anchorage
- installed extent
Inspect this object’s readings →View source IMG_1327 ↗
assembly · roof-img1327-beam-encasement-detail-01Modeling: not-modeled
Beam encasement section in typical roof slab detail
Research representation: none. Architectural checks: pending.
Roof
3 recorded properties
Still to extract or check- beam mark and size
- confirmed side and bottom encasement witnesses
- encasement material specification
- continuity
- world placement
Inspect this object’s readings →View source IMG_1327 ↗
reinforcement · roof-img1327-beam-mesh-01Modeling: not-modeled
Mesh leader at beam encasement
Research representation: none. Architectural checks: pending.
Roof
1 recorded properties
Still to extract or check- mesh specification
- cover
- anchorage
- installed extent
Inspect this object’s readings →View source IMG_1327 ↗
assembly · detail-20261011o-img1327-vault-roofModeling: not-modeled
Typical vault roof reinforcement
Research representation: none. Architectural checks: pending.
Floor assignment pending
5 recorded properties
Still to extract or check- Vault instance, room and floor assignment
- Steel diameter glyph, material grade, bar lengths and anchorage
- Slab/wall thickness, clear cover and actual spacing endpoint registration
Inspect this object’s readings →View source IMG_1327 ↗
assembly · detail-20261011o-img1327-vault-wallModeling: not-modeled
Typical vault wall reinforcement
Research representation: none. Architectural checks: pending.
Floor assignment pending
7 recorded properties
Still to extract or check- Vault instance, room and floor assignment
- Steel diameter glyph, material grade, bar lengths and anchorage
- Slab/wall thickness, clear cover and actual spacing endpoint registration
Inspect this object’s readings →View source IMG_1327 ↗
assembly · structure-20261011b-lightcourt-raised-wall-detailModeling: not-modeled
Raised seventh-floor light-court wall slab reinforcement detail
Research representation: none. Architectural checks: pending.
Seventh floor
1 recorded properties
Still to extract or check- Complete fine-fraction/member schedule transcription
- Historical instance mapping and endpoint registration
- Annotated revisions and companion notes reconciliation
- Accepted connections and modeling checks
Inspect this object’s readings →View source IMG_1327 ↗
assembly · structure-20261012b-penthouse-slab-ruleModeling: not-modeled
Penthouse floors, sheave service landings and fan-room floor slab specification
Research representation: none. Architectural checks: pending.
Floor assignment pending
15 recorded properties
Still to extract or check- Complete member/plate/bar fraction transcription
- Historical instance and source-to-plan registration
- Revision authority and companion applicability
- Connection and modeling acceptance checks
Inspect this object’s readings →View source IMG_1327 ↗
assembly · structure-20261012b-main-entrance-slabModeling: not-modeled
Detail of slab over Main entrance
Research representation: none. Architectural checks: pending.
Floor assignment pending
6 recorded properties
Still to extract or check- Complete member/plate/bar fraction transcription
- Historical instance and source-to-plan registration
- Revision authority and companion applicability
- Connection and modeling acceptance checks
Inspect this object’s readings →View source IMG_1327 ↗
material-specification · framingwitness1014g-img1327-vault-steel-ruleModeling: not-modeled
Typical vault steel literal rule
Research representation: none. Architectural checks: pending.
Floor assignment pending
1 recorded properties
Still to extract or check- No physical diameter unit established by½φ.
- ALL STEEL IN VAULTS TO BE½φ is a literal fraction/diameter designation; no independently printed physical diameter unit established.
- Hooked-one-end/stagger-ends clause crosswalks to existing verified same-image reading; slab and roof fields still require mapping.
- Complete source-to-instance registration, physical endpoints, installed quantities and revision authority remain unresolved.
- Unreviewed regions, companion sheets, schedules and fine fractions remain open; this package is not exhaustive coverage.
- Material grades, connection capacities, world transforms and independent model/as-built checks remain unestablished.
Inspect this object’s readings →View source IMG_1327 ↗
detail-type · structsched1013g-img1327-beam-fireproofingModeling: not-modeled
Typical beam fireproofing detail
Research representation: none. Architectural checks: pending.
Floor assignment pending
5 recorded properties
Still to extract or check- Complete source-to-plan registration and installed-instance applicability remain unresolved.
- Unreviewed sheet regions, notes, callouts, schedules and revision authority remain open.
- Material grades, full profiles, connection capacities and independent modeling checks unresolved.
Inspect this object’s readings →View source IMG_1327 ↗
detail-type · structsched1013g-img1327-column-fireproofingModeling: not-modeled
Typical column fireproofing mesh
Research representation: none. Architectural checks: pending.
Floor assignment pending
1 recorded properties
Still to extract or check- Complete source-to-plan registration and installed-instance applicability remain unresolved.
- Unreviewed sheet regions, notes, callouts, schedules and revision authority remain open.
- Material grades, full profiles, connection capacities and independent modeling checks unresolved.
Inspect this object’s readings →View source IMG_1327 ↗