An identified object is not a fully modeled object. Missing dimensions, locations and relationships remain explicit.
room · f7-room-721Modeling: not-modeled
721 · MENS TOILET
Research representation: boundary trace. Architectural checks: pending.
Seventh floor
Historical room number: 721
Source relationships · not a verified physical connection
18 recorded properties
Still to extract or check- Exact wall thickness/finish faces
- Local pilaster/reveal geometry
- Printed clear dimensions
- All openings and detail schedule
- Ceiling height/profile
- Registered W-235-to-world transform
- Exact finished room boundary and wall thicknesses
- Overall clear width, depth and ceiling height
- Fixture manufacturer, model and rough-in dimensions
- North-wall fixture type names
- Partition thickness, height, material, door leaves and hardware
- Entry-door exact jambs, leaf width, height and hardware
- Finish-schedule 4 material decoding
Inspect this object’s readings →View source IMG_1221 ↗
room · f7-room-720Modeling: not-modeled
720 · WOMENS TOILET
Research representation: boundary trace. Architectural checks: pending.
Seventh floor
Historical room number: 720
Source relationships · not a verified physical connection
18 recorded properties
Still to extract or check- Exact wall thickness/finish faces
- Local pilaster/reveal geometry
- Printed clear dimensions
- All openings and detail schedule
- Ceiling height/profile
- Registered W-235-to-world transform
- Exact finished room boundary and wall thicknesses
- Overall clear width, depth and ceiling height
- Fixture manufacturer, model and rough-in dimensions
- Rectangular wall-fixture type name
- Compartment clear widths, partition thickness, height, material, door leaves and hardware
- Entry-door exact jambs, leaf width, height and hardware
- Finish-schedule 4 material decoding
Inspect this object’s readings →View source IMG_1221 ↗
opening · f7-door-721Modeling: not-modeled
Men721 doorway
Research representation: boundary trace. Architectural checks: pending.
Seventh floor
Connects the men's toilet to the west-side service/entry sequence; other-side space identity remains unresolved.
Source relationships · not a verified physical connection
8 recorded properties · Room f7-room-721
Still to extract or check- Exact jamb/wall instance
- Printed width and height
- Sill/head elevations
- Door type/hardware
- Other-side space identity
- One or more connected rooms/landings remain unidentified
- Leaf count
- Printed width
- Printed height
- Thickness
- Door type
- Hardware
- Other-side room identity
Inspect this object’s readings →View source IMG_1221 ↗
opening · f7-door-720Modeling: not-modeled
Women720 doorway
Research representation: boundary trace. Architectural checks: pending.
Seventh floor
Connects the women's toilet to the west-side service/entry sequence; other-side space identity remains unresolved.
Source relationships · not a verified physical connection
8 recorded properties · Room f7-room-720
Still to extract or check- Exact jamb/wall instance
- Printed width and height
- Sill/head elevations
- Door type/hardware
- Other-side space identity
- One or more connected rooms/landings remain unidentified
- Leaf count
- Printed width
- Printed height
- Thickness
- Door type
- Hardware
- Other-side room identity
Inspect this object’s readings →View source IMG_1221 ↗
source-sheet · sheet-W235Modeling: not-modeled
W-235 · SPECIAL TOILETS
Research representation: none. Architectural checks: pending.
Floor assignment pending · Original mark: W-235
1931 design source sheet
2 recorded properties
Still to extract or check- W-235-to-IMG_1221 registration and accepted local/world transform
- Exact finished-face polygons for Rooms 720 and 721
- All room overall dimensions and ceiling heights
- Secure printed type labels for every unlabeled fixture symbol
- Fixture dimensions, manufacturers, elevations and rough-in offsets
- Compartment construction, heights, doors and hardware
- Room-entry door sizes, jambs, leaf counts, types and hardware
- Finish No. 4 and Finish No. 6 material schedule decoding
- Supply, waste, vent, floor-drain and cleanout connections
- Exact window assembly instances for the full-size toilet street-front frame detail
- All section dimensions, finish layers and material-code references
- Revision, date and approval history
Inspect this object’s readings →View source IMG_1272 ↗
plumbing-fixture · f7-room-721-fixture-wc-form-01Modeling: analytical-preview
Room 721 western south-wall fixture symbol 01
Research representation: control marker. Architectural checks: pending.
Seventh floor
South fixture bank, western symbol; visibly different from the two water-closet-form symbols to the east.
Source relationships · not a verified physical connection
2 recorded properties
Still to extract or check- Printed fixture type
- Earlier provisional water-closet-form classification retracted
- Manufacturer/model
- Dimensions
- Wall/rough-in offsets
- Elevation
- Material
- Supply/waste/vent connections
Inspect this object’s readings →View source IMG_1272 ↗
plumbing-fixture · f7-room-721-fixture-wc-form-02Modeling: analytical-preview
Room 721 water-closet-form fixture 02
Research representation: control marker. Architectural checks: pending.
Seventh floor
South fixture bank, middle 3-foot compartment. Classification: water-closet-form (probable-not-printed).
Source relationships · not a verified physical connection
2 recorded properties
Still to extract or check- Printed fixture type
- Manufacturer/model
- Dimensions
- Wall/rough-in offsets
- Elevation
- Material
- Supply/waste/vent connections
Inspect this object’s readings →View source IMG_1272 ↗
plumbing-fixture · f7-room-721-fixture-wc-form-03Modeling: analytical-preview
Room 721 water-closet-form fixture 03
Research representation: control marker. Architectural checks: pending.
Seventh floor
South fixture bank, eastern 3-foot compartment; adjacent to the janitor closet wall. Classification: water-closet-form (probable-not-printed).
Source relationships · not a verified physical connection
2 recorded properties
Still to extract or check- Printed fixture type
- Manufacturer/model
- Dimensions
- Wall/rough-in offsets
- Elevation
- Material
- Supply/waste/vent connections
Inspect this object’s readings →View source IMG_1272 ↗
plumbing-fixture · f7-room-721-north-wall-fixture-01Modeling: analytical-preview
Room 721 north-wall fixture 01
Research representation: control marker. Architectural checks: pending.
Seventh floor
Western of two repeated shallow wall-fixture symbols on the north wall.
Source relationships · not a verified physical connection
2 recorded properties
Still to extract or check- Fixture type
- Manufacturer/model
- Dimensions
- Spacing
- Elevation
- Material
- Supply/waste/vent connections
Inspect this object’s readings →View source IMG_1272 ↗
plumbing-fixture · f7-room-721-north-wall-fixture-02Modeling: analytical-preview
Room 721 north-wall fixture 02
Research representation: control marker. Architectural checks: pending.
Seventh floor
Eastern of two repeated shallow wall-fixture symbols on the north wall.
Source relationships · not a verified physical connection
2 recorded properties
Still to extract or check- Fixture type
- Manufacturer/model
- Dimensions
- Spacing
- Elevation
- Material
- Supply/waste/vent connections
Inspect this object’s readings →View source IMG_1272 ↗
source-audit-correction · f7-room-721-north-wall-fixture-03Modeling: not-modeled
Retracted erroneous third north-wall fixture identity
Research representation: none. Architectural checks: pending.
Seventh floor
Retained only as an audit identity so the earlier erroneous count cannot silently reappear. Classification: retracted-record (verified-correction).
0 recorded properties
Still to extract or check- No physical fixture corresponds to this retracted audit record
Inspect this object’s readings →View source IMG_1272 ↗
plumbing-fixture · f7-room-720-fixture-wc-form-01Modeling: analytical-preview
Room 720 water-closet-form fixture 01
Research representation: control marker. Architectural checks: pending.
Seventh floor
Northern fixture bank, western compartment. Classification: water-closet-form (probable-not-printed).
Source relationships · not a verified physical connection
2 recorded properties
Still to extract or check- Printed fixture type
- Manufacturer/model
- Dimensions
- Compartment clear width
- Wall/rough-in offsets
- Elevation
- Material
- Supply/waste/vent connections
Inspect this object’s readings →View source IMG_1272 ↗
plumbing-fixture · f7-room-720-fixture-wc-form-02Modeling: analytical-preview
Room 720 water-closet-form fixture 02
Research representation: control marker. Architectural checks: pending.
Seventh floor
Northern fixture bank, eastern compartment; adjacent to janitor closet wall. Classification: water-closet-form (probable-not-printed).
Source relationships · not a verified physical connection
2 recorded properties
Still to extract or check- Printed fixture type
- Manufacturer/model
- Dimensions
- Compartment clear width
- Wall/rough-in offsets
- Elevation
- Material
- Supply/waste/vent connections
Inspect this object’s readings →View source IMG_1272 ↗
plumbing-fixture · f7-room-720-rectangular-wall-fixture-01Modeling: analytical-preview
Room 720 rectangular west-wall fixture 01
Research representation: control marker. Architectural checks: pending.
Seventh floor
Mounted or set along the west wall south of the two northern compartments.
Source relationships · not a verified physical connection
2 recorded properties
Still to extract or check- Fixture type
- Manufacturer/model
- Dimensions
- Wall/rough-in offsets
- Elevation
- Material
- Supply/waste/vent connections
Inspect this object’s readings →View source IMG_1272 ↗
toilet-compartment-partition · f7-room-721-compartment-partition-01Modeling: analytical-preview
Room 721 compartment partition 01
Research representation: boundary trace. Architectural checks: pending.
Seventh floor
Divides the western and middle fixtures in the south fixture bank.
Source relationships · not a verified physical connection
5 recorded properties
Still to extract or check- Thickness
- Height
- Material
- Floor/wall anchorage
- Compartment door
- Door hardware
- Exact endpoint offsets
Inspect this object’s readings →View source IMG_1272 ↗
toilet-compartment-partition · f7-room-721-compartment-partition-02Modeling: analytical-preview
Room 721 compartment partition 02
Research representation: boundary trace. Architectural checks: pending.
Seventh floor
Divides the middle and eastern fixtures in the south fixture bank.
Source relationships · not a verified physical connection
5 recorded properties
Still to extract or check- Thickness
- Height
- Material
- Floor/wall anchorage
- Compartment door
- Door hardware
- Exact endpoint offsets
Inspect this object’s readings →View source IMG_1272 ↗
toilet-compartment-partition · f7-room-720-compartment-partition-01Modeling: analytical-preview
Room 720 compartment partition 01
Research representation: boundary trace. Architectural checks: pending.
Seventh floor
Separates the two northern fixture compartments.
Source relationships · not a verified physical connection
4 recorded properties
Still to extract or check- Clear bay widths
- Thickness
- Height
- Material
- Floor/wall anchorage
- Compartment doors
- Door hardware
- Exact endpoint offsets
Inspect this object’s readings →View source IMG_1272 ↗
service-room · f7-janitor-closet-W235Modeling: analytical-preview
Janitor closet adjacent to Rooms 720–721
Research representation: boundary trace. Architectural checks: pending.
Seventh floor · Original mark: JANITOR
East of the Rooms 720–721 fixture banks and west of their entry/service passage.
15 recorded properties
Still to extract or check- Printed room number
- Wall thicknesses
- Door exact size/hardware
- Ceiling height
- Floor elevation
- Finish-schedule 6 material decoding
- Registered world position
Inspect this object’s readings →View source IMG_1272 ↗
plumbing-fixture · f7-janitor-W235-mop-sink-01Modeling: analytical-preview
Janitor closet mop sink
Research representation: control marker. Architectural checks: pending.
Seventh floor · Original mark: MOP SINK
Inside the janitor closet at its southwest area.
Source relationships · not a verified physical connection
3 recorded properties
Still to extract or check- Manufacturer/model
- Width
- Depth
- Height
- Wall offsets
- Material
- Supply/waste/vent connections
Inspect this object’s readings →View source IMG_1272 ↗
window-assembly-type · W235-toilet-street-window-metal-frame-typeModeling: not-modeled
Full-size metal frame for obscure glass in toilets on street fronts
Research representation: none. Architectural checks: pending.
Floor assignment pending · Original mark: F.S. DETAIL OF METAL FRAME FOR OBSCURE GLASS IN TOILETS ON STREET FRONTS
Typical toilet-on-street-front head, jamb and sill assembly; no Room 720/721 instance assignment is made in this pass.
4 recorded properties
Still to extract or check- Applicable opening instances
- Every profile dimension
- Gauge
- Fasteners
- Anchorage
- Glass thickness
- Marble thickness
- Masonry-opening relation
- World orientation
Inspect this object’s readings →View source IMG_1272 ↗
evidence-gate · seventh-floor-w235-to-plan-registration-gateModeling: not-modeled
W-235 Rooms 720–721 detail-to-plan registration gate
Research representation: none. Architectural checks: pending.
Seventh floor · Original mark: W-235 / ROOMS 720–721
Source relationships · not a verified physical connection
8 recorded properties
Still to extract or check- Accepted like-for-like endpoint classification on W-235 and IMG_1221: finish face, structural face or centerline
- At least four independently recognizable controls distributed around the complete 720/721 block with reviewed point coordinates
- At least two held-out controls with residuals within the adopted tolerance
- Rectified or orthogonally scanned W-235 source, or a registered dimension network sufficient to avoid photographed line scaling
- Accepted seventh-floor finished-face polygons for Rooms 720 and 721
- Accepted Elevator No.1 shaft-face or clear-hatch geometry usable as an independent asymmetrical check
- Printed offsets locating each fixture and partition from classified room faces
Inspect this object’s readings →View source IMG_1272 ↗
assembly · courtfinish-w235-swing-toilet-stall-prototypeModeling: not-modeled
W235 swing-room toilet stall prototype
Research representation: none. Architectural checks: pending.
Floor assignment pending
3 recorded properties
Still to extract or check- Installed room/floor registration
- Marble thickness/species and partition fastening
- Door hardware, leaf thickness and full witness chains
- Companion schedules and revision authority
Inspect this object’s readings →View source IMG_1272 ↗
assembly · courtfinish-w235-swing-shower-stall-prototypeModeling: not-modeled
W235 swing-room shower stall prototype
Research representation: none. Architectural checks: pending.
Floor assignment pending
2 recorded properties
Still to extract or check- Installed room/floor registration and quantity
- Floor lowering numeral and waterproofing/drain specification
- Wood species/finish, hardware and leaf thickness
- Complete dimensions, companion schedules and revision authority
Inspect this object’s readings →View source IMG_1272 ↗