Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1265 · Folder 189

Tor Stair

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial timed visual review: Partial sequential 1000px JPEG65 locator review of public/archive/drawings/complete-upright/IMG_1265.webp after OCR/catalogue and existing reports. Actual clockwise reading rotation 0 degrees. Normalized access-image regions before rotation. Full fine-region extraction remains outstanding. Partial timed visual review: Text-first OCR/queue/prior-package audit only; existing verified properties reused without duplication. Orientation not rechecked where null. Partial timed visual review: Typical section at window for Stairs A and C; existing B/D/E and handrail schedule evidence reused. Partial timed visual review: Upper-left typical A/C construction crop. Other common B/D/E and railing facts preserved in existing IMG1122/1123 packages. Partial timed visual review: B/D/E flight rail and landing-newel witness endpoint classes. Two crops; full physical height above tread remains unresolved. Partial timed visual review: Selected construction and reference-face review only; source evidence does not authorize physical geometry. Partial timed visual review: Bounded endpoint/profile regions only; no complete-sheet extraction or physical geometry approval. Partial timed visual review: Text reuse only; no fresh pixel evidence or exhaustive-review claim.

Highlighted reading: PANELLED RISERS / REPLACEABLE SAFETY TREADS. Separate arrows identify vertical panelled risers and removable top safety-tread components. Material/product, thickness, fastening and replacement clearance remain unresolved.

Show every recorded property on this drawing →

Unresolved extraction work
  • Partial locator only: review all fine dimensions, specifications, note regions and companion details
  • Reconcile original linework with handwritten annotations/revisions
  • Register physical instances, quantities, element dimensions and spatial relationships
  • Remaining fractional dimensions and endpoint classes
  • Host wall, opening, landing and component profiles
  • Companion sheet registration and revision reconciliation
  • Independent placement/model checking
  • All unreviewed fabrication details and material-code cells
  • Newel tube/cap profiles and connections
  • W225/W226 storey-specific registration
  • Independent overlay and fabrication checking
  • Complete fractional dimensions and witness endpoint classification
  • Installed instance registration and component quantities
  • Companion details and handwritten revision reconciliation
  • Independent modeling and checks
  • Complete fine dimension chains and classified rough/finish endpoints
  • Source-to-building registration, landing polygons, slab openings and installed instances
  • Companion detail/revision authority and independent physical checks
  • Accepted rail-to-rail clear width, closed landing/slab-opening boundaries and headroom
  • Complete material/gauge/fastener schedules, cap/moulding profiles and finish extents; remaining notes and revisions not fully reviewed
  • Checked source-to-building transforms, storey/installed instance applicability and independent physical checks
  • Complete rail/string/cap offsets, tread product and panelled-riser materials not certified
  • Rail-to-rail clear width and rough/finish face classification remain unaccepted
  • Closed landing/slab-opening boundaries, physical elevations and headroom
  • Checked source-to-building transform and installed instance applicability
  • Full unreviewed notes, fine profiles, connections and revision authority
  • Complete fine dimension/profile chains, fasteners, connection details, material and finish extents remain partial.
  • Installed instances, floor applicability, governing revisions, closed landings/shaft boundaries, headroom, accepted registration and independent physical checks remain unresolved.
  • String cap/base offset fractions not reopened: prior native crop failed; clearer independent evidence is still required.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. The gold outline locates the selected reading. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

4 matching objects

An identified object is not a fully modeled object. Missing dimensions, locations and relationships remain explicit.

assembly · parallel-img1265-detailModeling: not-modeled

Typical stair details A through H

Research representation: none. Architectural checks: pending.

Floor assignment pending

10 recorded properties

Still to extract or check
  • Partial locator only: review all fine dimensions, specifications, note regions and companion details
  • Reconcile original linework with handwritten annotations/revisions
  • Register physical instances, quantities, element dimensions and spatial relationships
  • Fine construction, hardware, finishes and full region dimensions unresolved
Inspect this object’s readings →

View source IMG_1265 ↗

assembly · closure1011z-w228-ac-window-sectionModeling: not-modeled

W228 typical section at window for Stairs A and C

Research representation: none. Architectural checks: pending.

Floor assignment pending · Original mark: A & C

7 recorded properties

Still to extract or check
  • Channel section series and weight
  • Plate-string metal specification and gauge standard
  • All connection rivet/bolt/weld sizes
  • Marble and steel profiles, member lengths and window registration
  • Stair/storey installation exceptions
Inspect this object’s readings →

View source IMG_1265 ↗

assembly · detail-w228-staira-c-upper-left-constructionModeling: not-modeled

W228 upper-left typical construction for Stair A basement–second and Stair C first–second

Research representation: none. Architectural checks: pending.

Basement · First floor · Second floor

10 recorded properties

Still to extract or check
  • Complete fractional dimensions and witness endpoint classification
  • Installed instance registration and component quantities
  • Companion details and handwritten revision reconciliation
  • Independent modeling and checks
Inspect this object’s readings →

View source IMG_1265 ↗

assembly · stair-w228-bde-rail-profile-registerModeling: not-modeled

W228 B/D/E typical flight and landing rail/newel witnesses

Research representation: none. Architectural checks: pending.

Floor assignment pending · Original mark: B, D, E

45 recorded properties

Still to extract or check
  • Precisely classified rail-height witness endpoints
  • Tube fraction, wall thickness and material specification
  • Post spacing, member extents, connections and floor exceptions
  • Full fine dimension chains and witness endpoint classes
  • Source-to-building registration, slab openings and installed instances
  • Companion details, revision authority and independent physical checks
Inspect this object’s readings →

View source IMG_1122 ↗

View all source photographs →