Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1267 · Folder 189

DETAIL OF ELEVATOR NO. 2

Sheet W230

Extraction: Reviewed · extraction partial. Bounded first-floor elevator audit: DETAIL OF ELEVATOR NO. 2. First-floor Elevator No. 2 plan, column marks, axis order, clear-hatch labels and local offset witnesses. Elevator detail-to-W3 physical-placement gate: DETAIL OF ELEVATOR NO. 2. W230 first-floor Elevator 2 plan: Column 83-to-east-outside-enclosure-face witness, Column 83-to-east-clear-hatch-edge witness, printed 7-foot clear width and resulting world-X clear-hatch edge pair. Elevator-front bounded gate: Elevator 2 east enclosure face and one-axis clear-hatch controls. Partial timed visual review: Text-first OCR/queue/prior-package audit only; existing verified properties reused without duplication. Orientation not rechecked where null. Partial timed visual review: Text reuse only; no fresh pixel evidence or exhaustive-review claim.

Unresolved extraction work
  • Accepted world wall faces and exact shaft polygons for all three elevators
  • Registered relationship between W229/W230/W231 detail coordinates and W3 world coordinates
  • Rough-versus-finished enclosure wall planes and wall thicknesses
  • W217 title-block confirmation and exact endpoint interpretation for the 3'-6" and 6'-9 3/4" door readings
  • Exact first-floor Elevator 3 door width, height, jamb/head/sill and rough opening
  • Readable Elevator 3 vertical hatch/shaft witness
  • Car/cab/platform sizes, rail/counterweight coordinates, pit depths and overhead clearances
  • Accepted ramp length, slope and threshold build-up at Elevator 3
  • Architecturally accepted reconciliation of all floor traces, especially the fourth-floor mechanical underlay
  • World-Z clear-hatch offsets, finite enclosure-face endpoints, wall thickness and physical construction remain unresolved.
  • For W229, the west outside enclosure face is fixed at world X = -65.020833 ft and the south/north clear-hatch edges are fixed at world Z = 46/56 ft; both clear-hatch world-X edges remain unresolved. For W230, the east outside enclosure face is fixed at X = 65.020833 ft and the clear-hatch east/west edges at X = 66.083333/73.083333 ft; both clear-hatch world-Z edges remain unresolved. Both elevators still lack finite enclosure-face endpoints, opposite faces, wall thickness and complete hatch-to-wall construction.
  • For W231, an exact non-collinear column/grid frame and a complete, classified shaft or clear-hatch width/depth chain.
  • Rough-face versus finish-face classification and wall thickness for each enclosure side.
  • Independently accepted matching W3 hatch or shaft faces and a reported hold-out corner residual.
  • Pit depth, overhead, slab opening and cross-floor continuation evidence for each elevator independently.
  • World wall plane and jamb-center/inside-jamb offsets for all three entrances.
  • Operating clear width and height, rough opening, leaf overlap/travel, sill, head and wall-thickness build-up.
  • Elevator 3 first-floor entrance dimensions and endpoint classes.
  • An independent check tying each local door centerline to the corresponding W3 landing wall.
  • Cab-to-hatch origin, platform size and inside-clear dimensions.
  • Guide-rail, counterweight and bracket centerlines tied to classified hatch faces.
  • Confirmed assignment of W219 Cab E elevations to Elevator 1, 2 or 3.
  • Door operator, travel/pocket and emergency-exit geometry.
  • Dimensioned horizontal extents and wall-face endpoints for the Elevator 1 vestibule and Elevator 2 Broadway foyer thresholds.
  • Elevator 3 ramp length, slope, threshold build-up and exact landing boundary at EL. 93.25 and EL. 95.33.
  • Registered sill/head coordinates and independent correspondence to W3 landing traces.
  • As-built confirmation before accepting vertical shaft or landing continuity.
  • North and south endpoints of the accepted outside enclosure face
  • World Z coordinates of both 10-foot clear-hatch edges
  • Enclosure wall thickness and opposite wall faces
  • Floor-opening construction, vertical extent, pit and overhead continuation
  • Complete physical shaft, door, cab and landing transforms
  • A readable first-floor W217 Section E or applicable companion section with front and back faces and exact profile/depth dimensions for one named component, plus complete width and height endpoints for that same component.
  • Printed or independently checked panel extents before any ornament panels are given physical sizes; retain panel instances without fabricated dimensions until then.
  • Classified first-floor host wall face, thickness and jamb/reveal/sill/head interfaces tied to named W229 or W230 controls and the corresponding W3 wall or Bay P station.
  • An independent corresponding-face or endpoint residual within a stated tolerance for the chosen physical front, preserving conflicts and W3 trace uncertainty separately.
  • Remaining fractional dimensions and endpoint classes
  • Host wall, opening, landing and component profiles
  • Companion sheet registration and revision reconciliation
  • Independent placement/model checking
  • Complete fine dimension/profile chains, fasteners, connection details, material and finish extents remain partial.
  • Installed instances, floor applicability, governing revisions, closed landings/shaft boundaries, headroom, accepted registration and independent physical checks remain unresolved.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

6 matching objects

An identified object is not a fully modeled object. Missing dimensions, locations and relationships remain explicit.

shaft · f1-elevator-2Modeling: not-modeled

ELEVATOR No. 2

Research representation: boundary trace. Architectural checks: pending.

First floor · Basement · Second floor · Third floor · Fourth floor · Fifth floor · Sixth floor · Seventh floor · Original mark: 2

Broadway/Main side; adjacent Stair C. qualitative visual relationship only; no coordinate trace

Source relationships · not a verified physical connection

20 recorded properties

Still to extract or check
  • Circled numeric marks elsewhere in this plan are not assigned as room numbers. This record identifies an instance, not a completed room enclosure.
  • Registered position and relationships
  • Printed clear width
  • Printed clear depth
  • Door size
  • Sill/head elevations
  • Pit and overhead
  • Accepted world shaft polygon and wall faces
  • Masonry wall thicknesses and finish offsets
  • Car platform/cab dimensions and rail locations
  • Pit depth and overhead
  • Accepted door jamb stations and rough opening
Inspect this object’s readings →

View source IMG_1202 ↗

opening · f1-door-elevator-1Modeling: not-modeled

Elevator No. 1 threshold

Research representation: none. Architectural checks: pending.

First floor

Elevator No. 1 page-top side; observed connections: f1-room-sixth-vestibule ↔ f1-elevator-1. Exact host wall remains unresolved.

Source relationships · not a verified physical connection

64 recorded properties · Room assignment not established

Still to extract or check
  • Exact wall instance and jamb station
  • Sill/head elevation
  • Opening type/hardware
  • Clear opening versus door-panel dimension
  • Rough opening
  • Head/sill section
  • Exact jamb stations
  • Operating clear width and height after door travel
  • Rough opening width and height
  • Sill, threshold and head sections/build-up
  • Individual leaf widths, thicknesses, overlap and travel
  • Outer ornamental-surround dimensions
  • Wall-face assignment and wall thickness
  • Registered world position and orientation
  • Accepted physical host-wall face and thickness
  • Exact entrance depth relative to the W229 clear-hatch edge
  • Rough opening and operating clear width/height
  • Jamb, reveal, frame, sill, threshold and door-leaf construction
  • Complete shaft, cab, guide, pit, overhead and machinery transforms
  • Independent as-built check
Inspect this object’s readings →

View source IMG_1202 ↗

opening · f1-door-elevator-2Modeling: not-modeled

Elevator No. 2 threshold

Research representation: none. Architectural checks: pending.

First floor

Elevator No. 2 page-top side; observed connections: f1-room-broadway-foyer ↔ f1-elevator-2. Exact host wall remains unresolved.

Source relationships · not a verified physical connection

52 recorded properties · Room assignment not established

Still to extract or check
  • Exact wall instance and jamb station
  • Sill/head elevation
  • Opening type/hardware
  • Clear opening versus door-panel dimension
  • Rough opening
  • Head/sill section
  • Exact jamb stations
  • Operating clear width and height after door travel
  • Rough opening width and height
  • Sill, threshold and head sections/build-up
  • Individual leaf widths, thicknesses, overlap and travel
  • Outer ornamental-surround dimensions
  • Wall-face assignment and wall thickness
  • Registered world position and orientation
Inspect this object’s readings →

View source IMG_1202 ↗

shaft-opening · f1-elevator-2-clear-hatchModeling: not-modeled

Elevator No. 2 clear hatch

Research representation: none. Architectural checks: pending.

First floor

10 recorded properties

Still to extract or check
  • Exact relation of the 7'-5 3/4" witness to hatch, cab and finished enclosure faces
  • South clear-hatch edge world Z
  • North clear-hatch edge world Z
  • Floor-opening construction and thickness
  • Pit and overhead continuation
  • Complete physical hatch transform
Inspect this object’s readings →

View source IMG_1267 ↗

registration-gate · elevator-w229-w231-to-w3-registration-gateModeling: not-modeled

W229/W230/W231 elevator detail controls to W3 trace registration gate

Research representation: none. Architectural checks: pending.

First floor

Source relationships · not a verified physical connection

11 recorded properties

Still to extract or check
  • For W229, the west outside enclosure face is fixed at world X = -65.020833 ft and the south/north clear-hatch edges are fixed at world Z = 46/56 ft; both clear-hatch world-X edges remain unresolved. For W230, the east outside enclosure face is fixed at X = 65.020833 ft and the clear-hatch east/west edges at X = 66.083333/73.083333 ft; both clear-hatch world-Z edges remain unresolved. Both elevators still lack finite enclosure-face endpoints, opposite faces, wall thickness and complete hatch-to-wall construction.
  • For W231, an exact non-collinear column/grid frame and a complete, classified shaft or clear-hatch width/depth chain.
  • Rough-face versus finish-face classification and wall thickness for each enclosure side.
  • Independently accepted matching W3 hatch or shaft faces and a reported hold-out corner residual.
  • Pit depth, overhead, slab opening and cross-floor continuation evidence for each elevator independently.
  • World wall plane and jamb-center/inside-jamb offsets for all three entrances.
  • Operating clear width and height, rough opening, leaf overlap/travel, sill, head and wall-thickness build-up.
  • Elevator 3 first-floor entrance dimensions and endpoint classes.
  • An independent check tying each local door centerline to the corresponding W3 landing wall.
  • Cab-to-hatch origin, platform size and inside-clear dimensions.
  • Guide-rail, counterweight and bracket centerlines tied to classified hatch faces.
  • Confirmed assignment of W219 Cab E elevations to Elevator 1, 2 or 3.
  • Door operator, travel/pocket and emergency-exit geometry.
  • Dimensioned horizontal extents and wall-face endpoints for the Elevator 1 vestibule and Elevator 2 Broadway foyer thresholds.
  • Elevator 3 ramp length, slope, threshold build-up and exact landing boundary at EL. 93.25 and EL. 95.33.
  • Registered sill/head coordinates and independent correspondence to W3 landing traces.
  • As-built confirmation before accepting vertical shaft or landing continuity.
Inspect this object’s readings →

View source IMG_1202 ↗

architectural-face-control · f1-elevator-2-w230-east-enclosure-face-controlModeling: not-modeled

Elevator 2 · W230 east outside enclosure face control

Research representation: none. Architectural checks: pending.

First floor · Original mark: 2'-0 1/4"

Source relationships · not a verified physical connection

7 recorded properties

Still to extract or check
  • North endpoint world Z
  • South endpoint world Z
  • Wall thickness and opposite face
  • Vertical extent
  • Complete physical shaft transform
Inspect this object’s readings →

View source IMG_1267 ↗

View all source photographs →