Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
f1-door-elevator-1verified · derived
Elevator No. 1 analytical finished-entrance base · project-local vertical coordinate
Y = 0 ft · first-floor finished-floor datum0 ft
Envelope base coordinate only; sill and threshold construction remain unresolved.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: ELEVATOR No. 2; ELEVATOR 1 SIMILAR
W217 supplies the separately registered 3-foot-6-inch finished width and 6-foot-9.75-inch finished-floor-to-head height for Elevator No. 1.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: ELEVATOR NO. 1; VESTIBULE; parallel threshold/door lines facing vestibule
The prior W3 trace is retained as a provisional entrance-center witness with 2-foot uncertainty. Its traced 4.602-foot length is not used as the finished or operating width.
Calculated from: frame-first-floor-finish
f1-door-elevator-1verified · derived
Elevator No. 1 analytical finished-entrance center · world south/north coordinate
Z = 47.344 ft47.344 ft
Accepted only for the zero-thickness evidence-review envelope and retains W3's 2-foot trace uncertainty.
IMG_1126 · sheet-W229 · Locate on drawing ↗Drawing notation: 1ST FLOOR PLAN; ELEVATOR No. 1; 7'-0" CLEAR HATCH; 10'-0" CLEAR HATCH
Targeted review confirms that the first-floor landing entrance is on the page-top/south enclosure face and runs in the W229 local-u direction, which the accepted symbolic column frame maps to building +X west/Broadway. The crop does not establish wall thickness or a physical face offset.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: ELEVATOR NO. 1; VESTIBULE; parallel threshold/door lines facing vestibule
The prior W3 trace is retained as a provisional entrance-center witness with 2-foot uncertainty. Its traced 4.602-foot length is not used as the finished or operating width.
Calculated from: f1-door-elevator-1-jamb-1-north, f1-door-elevator-1-jamb-2-north
f1-door-elevator-1verified · derived
W3 traced threshold acute orientation difference from W229 building-X entrance direction
1.269987°1.269987 deg
Orientation check only; the exact building-axis direction is used for the analytical envelope.
IMG_1126 · sheet-W229 · Locate on drawing ↗Drawing notation: 1ST FLOOR PLAN; ELEVATOR No. 1; 7'-0" CLEAR HATCH; 10'-0" CLEAR HATCH
Targeted review confirms that the first-floor landing entrance is on the page-top/south enclosure face and runs in the W229 local-u direction, which the accepted symbolic column frame maps to building +X west/Broadway. The crop does not establish wall thickness or a physical face offset.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: ELEVATOR NO. 1; VESTIBULE; parallel threshold/door lines facing vestibule
The prior W3 trace is retained as a provisional entrance-center witness with 2-foot uncertainty. Its traced 4.602-foot length is not used as the finished or operating width.
Calculated from: f1-door-elevator-1-jamb-1-west, f1-door-elevator-1-jamb-1-north, f1-door-elevator-1-jamb-2-west, f1-door-elevator-1-jamb-2-north, W229-to-W3-u-axis
f1-door-elevator-1verified · derived
Centered W217 3-foot-6-inch finished-entrance endpoint residual against W3 trace
0.552857 ft each0.552857 ft
Both residuals are below W3's recorded 2-foot trace uncertainty; the W3 traced width is not used as an architectural width.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: ELEVATOR No. 2; ELEVATOR 1 SIMILAR
W217 supplies the separately registered 3-foot-6-inch finished width and 6-foot-9.75-inch finished-floor-to-head height for Elevator No. 1.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: ELEVATOR NO. 1; VESTIBULE; parallel threshold/door lines facing vestibule
The prior W3 trace is retained as a provisional entrance-center witness with 2-foot uncertainty. Its traced 4.602-foot length is not used as the finished or operating width.
Calculated from: elevator-w217-e1-finished-entrance-width, f1-door-elevator-1-jamb-1-west, f1-door-elevator-1-jamb-1-north, f1-door-elevator-1-jamb-2-west, f1-door-elevator-1-jamb-2-north
f1-door-elevator-1verified · derived
W3 traced threshold length minus W217 printed finished width
1.102130 ft · trace not used as width1.10213 ft
Documents why the provisional W3 trace cannot replace the printed finished width or establish operating clearance.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: ELEVATOR No. 2; ELEVATOR 1 SIMILAR
W217 supplies the separately registered 3-foot-6-inch finished width and 6-foot-9.75-inch finished-floor-to-head height for Elevator No. 1.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: ELEVATOR NO. 1; VESTIBULE; parallel threshold/door lines facing vestibule
The prior W3 trace is retained as a provisional entrance-center witness with 2-foot uncertainty. Its traced 4.602-foot length is not used as the finished or operating width.
Calculated from: f1-door-elevator-1-width-trace, elevator-w217-e1-finished-entrance-width
f1-door-elevator-1unreviewed · derived
Diagnostic W3 threshold-center plane offset from W229 south clear-hatch edge
1.344 ft · diagnostic only1.344 ft
Different face classes and unresolved wall/door depth make this a diagnostic gap, not a construction dimension.
IMG_1126 · sheet-W229 · Locate on drawing ↗Drawing notation: 1ST FLOOR PLAN; ELEVATOR No. 1; 7'-0" CLEAR HATCH; 10'-0" CLEAR HATCH
Targeted review confirms that the first-floor landing entrance is on the page-top/south enclosure face and runs in the W229 local-u direction, which the accepted symbolic column frame maps to building +X west/Broadway. The crop does not establish wall thickness or a physical face offset.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: ELEVATOR NO. 1; VESTIBULE; parallel threshold/door lines facing vestibule
The prior W3 trace is retained as a provisional entrance-center witness with 2-foot uncertainty. Its traced 4.602-foot length is not used as the finished or operating width.
Calculated from: W229-W3-e1-entrance-world-center-z, w229-e1-clear-hatch-south-edge-world-z
f1-door-elevator-1verified · derived
Elevator No. 1 analytical finished-entrance envelope placement
Accepted · zero-thickness evidence review onlyW229 verifies the entrance face and exact building-axis direction; W3 supplies a provisional center with 2-foot uncertainty; W217 supplies exact finished width and height.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: ELEVATOR No. 2; ELEVATOR 1 SIMILAR
W217 supplies the separately registered 3-foot-6-inch finished width and 6-foot-9.75-inch finished-floor-to-head height for Elevator No. 1.
IMG_1126 · sheet-W229 · Locate on drawing ↗Drawing notation: 1ST FLOOR PLAN; ELEVATOR No. 1; 7'-0" CLEAR HATCH; 10'-0" CLEAR HATCH
Targeted review confirms that the first-floor landing entrance is on the page-top/south enclosure face and runs in the W229 local-u direction, which the accepted symbolic column frame maps to building +X west/Broadway. The crop does not establish wall thickness or a physical face offset.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: ELEVATOR NO. 1; VESTIBULE; parallel threshold/door lines facing vestibule
The prior W3 trace is retained as a provisional entrance-center witness with 2-foot uncertainty. Its traced 4.602-foot length is not used as the finished or operating width.
f1-door-elevator-1verified · observed
Elevator No. 1 physical entrance/frame/wall-cut placement
WithheldHost-wall face/depth, rough opening, jamb and reveal depth, frame construction, sill, operating leaves, shaft walls, cab, rails, pit, overhead, equipment and independent as-built verification remain unresolved.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: ELEVATOR No. 2; ELEVATOR 1 SIMILAR
W217 supplies the separately registered 3-foot-6-inch finished width and 6-foot-9.75-inch finished-floor-to-head height for Elevator No. 1.
IMG_1126 · sheet-W229 · Locate on drawing ↗Drawing notation: 1ST FLOOR PLAN; ELEVATOR No. 1; 7'-0" CLEAR HATCH; 10'-0" CLEAR HATCH
Targeted review confirms that the first-floor landing entrance is on the page-top/south enclosure face and runs in the W229 local-u direction, which the accepted symbolic column frame maps to building +X west/Broadway. The crop does not establish wall thickness or a physical face offset.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: ELEVATOR NO. 1; VESTIBULE; parallel threshold/door lines facing vestibule
The prior W3 trace is retained as a provisional entrance-center witness with 2-foot uncertainty. Its traced 4.602-foot length is not used as the finished or operating width.
upper-envelope-curtain-mainunreviewed · derived
Analytical ruled-envelope strip count
7 zero-thickness strips; preview only7 count
Vertically project the registered W3 north segment only to the second-floor datum, then connect matching north cardinal edges of independently registered upper-floor traces. No vertical wall face, thickness, opening cut or physical construction is implied.
IMG_1202 · W3 · Locate on drawing ↗Drawing notation: FIRST FLOOR PLAN
Existing W3 enclosed-floor outer trace reused; not reopened for this derivation. The Madison loading indentation is retained as five separate curtain segments.
IMG_1335 · Locate on drawing ↗Drawing notation: FOURTH FLOOR PLAN / HEATING AND LIGHTING
Existing provisional MEP-underlay outer trace; not reopened and not treated as an accepted architectural wall face.
Calculated from: f1-enclosed-floor-outline-footprint-trace, f2-floor-outline-footprint-trace, f3-floor-outline-footprint-trace, f4-floor-outline-footprint-trace, f5-floor-outline-footprint-trace, f6-enclosed-floor-outline-footprint-trace, f7-enclosed-floor-outline-footprint-trace, f8-enclosed-envelope-footprint-trace, frame-first-floor-finish, frame-second-floor-finish, env-sixth-F3-level, env-sixth-F4-level, env-sixth-F5-level, frame-sixth-floor-finish, env-sixth-F7-level, frame-eighth-floor-schedule-finish
upper-envelope-curtain-broadwayunreviewed · derived
Analytical ruled-envelope strip count
7 zero-thickness strips; preview only7 count
Vertically project the registered W3 west segment only to the second-floor datum, then connect matching west cardinal edges of independently registered upper-floor traces. No vertical wall face, thickness, opening cut or physical construction is implied.
IMG_1202 · W3 · Locate on drawing ↗Drawing notation: FIRST FLOOR PLAN
Existing W3 enclosed-floor outer trace reused; not reopened for this derivation. The Madison loading indentation is retained as five separate curtain segments.
IMG_1335 · Locate on drawing ↗Drawing notation: FOURTH FLOOR PLAN / HEATING AND LIGHTING
Existing provisional MEP-underlay outer trace; not reopened and not treated as an accepted architectural wall face.
Calculated from: f1-enclosed-floor-outline-footprint-trace, f2-floor-outline-footprint-trace, f3-floor-outline-footprint-trace, f4-floor-outline-footprint-trace, f5-floor-outline-footprint-trace, f6-enclosed-floor-outline-footprint-trace, f7-enclosed-floor-outline-footprint-trace, f8-enclosed-envelope-footprint-trace, frame-first-floor-finish, frame-second-floor-finish, env-sixth-F3-level, env-sixth-F4-level, env-sixth-F5-level, frame-sixth-floor-finish, env-sixth-F7-level, frame-eighth-floor-schedule-finish
upper-envelope-curtain-madisonunreviewed · derived
Analytical ruled-envelope strip count
11 zero-thickness strips; preview only11 count
Vertically project all five registered W3 south/loading-indentation segments only to the second-floor datum, then connect matching south cardinal edges of independently registered upper-floor traces. No vertical wall face, thickness, opening cut or physical construction is implied.
IMG_1202 · W3 · Locate on drawing ↗Drawing notation: FIRST FLOOR PLAN
Existing W3 enclosed-floor outer trace reused; not reopened for this derivation. The Madison loading indentation is retained as five separate curtain segments.
IMG_1335 · Locate on drawing ↗Drawing notation: FOURTH FLOOR PLAN / HEATING AND LIGHTING
Existing provisional MEP-underlay outer trace; not reopened and not treated as an accepted architectural wall face.
Calculated from: f1-enclosed-floor-outline-footprint-trace, f2-floor-outline-footprint-trace, f3-floor-outline-footprint-trace, f4-floor-outline-footprint-trace, f5-floor-outline-footprint-trace, f6-enclosed-floor-outline-footprint-trace, f7-enclosed-floor-outline-footprint-trace, f8-enclosed-envelope-footprint-trace, frame-first-floor-finish, frame-second-floor-finish, env-sixth-F3-level, env-sixth-F4-level, env-sixth-F5-level, frame-sixth-floor-finish, env-sixth-F7-level, frame-eighth-floor-schedule-finish
upper-envelope-curtain-sixthunreviewed · derived
Analytical ruled-envelope strip count
7 zero-thickness strips; preview only7 count
Vertically project the registered W3 east segment only to the second-floor datum, then connect matching east cardinal edges of independently registered upper-floor traces. No vertical wall face, thickness, opening cut or physical construction is implied.
IMG_1202 · W3 · Locate on drawing ↗Drawing notation: FIRST FLOOR PLAN
Existing W3 enclosed-floor outer trace reused; not reopened for this derivation. The Madison loading indentation is retained as five separate curtain segments.
IMG_1335 · Locate on drawing ↗Drawing notation: FOURTH FLOOR PLAN / HEATING AND LIGHTING
Existing provisional MEP-underlay outer trace; not reopened and not treated as an accepted architectural wall face.
Calculated from: f1-enclosed-floor-outline-footprint-trace, f2-floor-outline-footprint-trace, f3-floor-outline-footprint-trace, f4-floor-outline-footprint-trace, f5-floor-outline-footprint-trace, f6-enclosed-floor-outline-footprint-trace, f7-enclosed-floor-outline-footprint-trace, f8-enclosed-envelope-footprint-trace, frame-first-floor-finish, frame-second-floor-finish, env-sixth-F3-level, env-sixth-F4-level, env-sixth-F5-level, frame-sixth-floor-finish, env-sixth-F7-level, frame-eighth-floor-schedule-finish
broadway-wall-witness-f1verified · printed
witness.outwardOffsetFromWestColumn
2′3″27 in
Reused W3 terminal witness, not newly checked masonry-face geometry.
Calculated from: f1-control-main-west-offset
broadway-wall-witness-f1unreviewed · derived
witness.worldX
78′7″ + 2′3″ = 80′10″80.833333 ft
Conditional outer witness coordinate. Do not treat as accepted lower-wall face.
Calculated from: structural-registration-origin-half-span, bway-plane-f1-west-witness-offset
broadway-wall-witness-f1unreviewed · derived
witness.differenceFromUpperEndSection
2′3″ − 1′10″ = 5″5 in
Difference of references with distinct story/face scopes; not an accepted physical setback.
Calculated from: bway-plane-f1-west-witness-offset, bway-plane-w403-end-offset
f1-public-lobby-architectural-envelopedisputed · printed
printed_ceiling_height
18'-9"18.75 ft
Reused from first-floor-topology.json, where the printed W3 text was independently verified. It does not prove a uniform height in every recess. Authoring eligibility: none-until-conflict-resolved. Report transcription; verify the cited drawing before promoting physical geometry.
Conflicting readings: lobby-height-report-reading-18-3
f1-public-lobby-postal-wall-systemunreviewed · observed
typical_service_module_width
customer counter modules repeatedly read about 7 feet 6 inchesThe report describes a repeated approximate reading without accepted station assignments.
IMG_1202 · sheet-W3 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing verified package; image not reopened. Named PUBLIC LOBBY and printed ceiling-height reading
IMG_1204 · sheet-W3 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit only; image not reopened. First-floor public-lobby plan, reported 18'-3" ceiling-height reading and repeated 14'/15' structural dimensions
IMG_1089 · sheet-W214 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit only. Lobby overview, floor/ceiling bay grid, Panels A-D and service-wall sequence
IMG_1302 · sheet-W214 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit only. Lobby overview, floor/ceiling bay grid, Panels A-D and service-wall sequence
IMG_1090 · sheet-W215 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit only. Bays E, I, K and B; bronze/glass screens, Letters/Packages, Registry, counters, money drawer and locks
IMG_1091 · sheet-W215 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit only. Bays E, I, K and B; bronze/glass screens, Letters/Packages, Registry, counters, money drawer and locks
IMG_1092 · sheet-W215 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit only. Bays E, I, K and B; bronze/glass screens, Letters/Packages, Registry, counters, money drawer and locks
IMG_1303 · sheet-W215 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit only. Bays E, I, K and B; bronze/glass screens, Letters/Packages, Registry, counters, money drawer and locks
IMG_1093 · sheet-W216 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit only. Parcel Post/Registry windows, roll-down curtains, staff-side casework and illuminated STAMPS sign
IMG_1094 · sheet-W216 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit only. Parcel Post/Registry windows, roll-down curtains, staff-side casework and illuminated STAMPS sign
IMG_1304 · sheet-W216 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit only. Parcel Post/Registry windows, roll-down curtains, staff-side casework and illuminated STAMPS sign
IMG_1095 · sheet-W217 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit and existing verified elevator package; images not reopened. Bay P directory, paired door, Elevator No. 2 entrance, clock and other glazed door/screen bays
IMG_1097 · sheet-W217 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit and existing verified elevator package; images not reopened. Bay P directory, paired door, Elevator No. 2 entrance, clock and other glazed door/screen bays
IMG_1098 · sheet-W217 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit and existing verified elevator package; images not reopened. Bay P directory, paired door, Elevator No. 2 entrance, clock and other glazed door/screen bays
IMG_1305 · sheet-W217 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit and existing verified elevator package; images not reopened. Bay P directory, paired door, Elevator No. 2 entrance, clock and other glazed door/screen bays
IMG_1099 · sheet-W-218 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit and existing writing-desk packages; images not reopened. Main Street foyer/lobby door-screen line, bulletin cases, bronze directory and lobby furniture family
IMG_1306 · sheet-W-218 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing text re-audit and existing writing-desk packages; images not reopened. Main Street foyer/lobby door-screen line, bulletin cases, bronze directory and lobby furniture family
IMG_1289 · sheet-WLF-246 · View drawing ↗Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches
Existing verified package plus re-audit report; image not reopened. P-5 Public Lobby and P-6 Registry/Box/Parcel Post alcove fixture types
f1-public-lobby-w217-bay-p-door-pairverified · derived
Analytical door center · world west/east coordinate
63.6025 ft (W3 midpoint registration)63.6025 ft
Accepted only for the zero-thickness analytical leaf envelopes; W3 retains 2-foot plan-trace uncertainty.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY P
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: BAY P
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
f1-public-lobby-w217-bay-p-door-pairverified · derived
Analytical door center · world south/north coordinate
41.6895 ft (W3 midpoint registration)41.6895 ft
Accepted only for the zero-thickness analytical leaf envelopes; W3 retains 2-foot plan-trace uncertainty.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY P
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: BAY P
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
f1-public-lobby-w217-bay-p-door-pairverified · derived
Analytical door plane rotation about building Y
-1.5873855067559648 rad-1.587386 rad
Maps W217 source-plan +X toward the W3 north/Elevator No. 2 end; applies only to analytical leaf surfaces.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY P
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: BAY P
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
f1-public-lobby-w217-bay-p-end-wall-assemblyverified · derived
Centered W217 overall endpoint residual at each W3 Bay P end
1.256343458758947 ft each1.256343 ft
Both endpoint residuals remain within the recorded 2-foot W3 trace allowance.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: BAY P
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
f1-public-lobby-w217-bay-p-door-pairverified · derived
Held-out W3 traced-door center residual
1.468130699730716 ft1.468131 ft
Independent center check within the 2-foot W3 trace allowance. The incomplete W3 segment is not used to resize W217.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: 3'-0" + 3'-0"
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: Double-leaf swing arcs
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
f1-public-lobby-w217-bay-p-door-pairdisputed · derived
Rejected W3 south doorway endpoint residual
2.338295206106527 ft · outside tolerance2.338295 ft
Outside tolerance and retained as evidence that the W3 swing-arc trace is not a complete jamb-to-jamb opening. It is excluded from placement acceptance.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: 3'-0" + 3'-0"
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: Double-leaf swing arcs
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
f1-public-lobby-w217-bay-p-door-pairverified · derived
Analytical leaf-envelope building placement
Accepted · zero-thickness evidence review onlyW217 supplies an exact symmetric 24'-11" Bay P plan, a 6-foot central paired door, and a separately chained 3'-6" Elevator No. 2 finished entrance. Centering that exact plan on the independently labeled W3 Bay P wall leaves 1.256-foot endpoint residuals and a 1.468-foot held-out door-center residual, both within W3's recorded 2-foot trace uncertainty. The W3 door trace is only 3.9 feet wide and its south endpoint fails the 2-foot check, so it is treated as an incomplete swing-arc trace and is not used to resize the verified W217 leaves. A separate old W3 line classified as the Elevator No. 2 threshold is 6.957 feet from the W217-predicted entrance center and differs in orientation by 89.695 degrees; targeted review confirms it is not the Bay P-parallel entrance plane, so that provisional trace is disputed and excluded. The checked registration places the zero-thickness analytical door leaves and Elevator No. 2 finished-entrance envelope only; it does not establish physical wall, frame, shaft, cab, or equipment geometry.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY P
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: BAY P
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
f1-public-lobby-w217-bay-p-door-pairverified · observed
Physical door/frame/wall-cut placement
WithheldPhysical geometry remains prohibited: Accepted physical wall face and wall thickness; Rough opening and operating clear dimensions; Frame, stile, rail, muntin and trim profiles; Glazing thickness and edge treatment; Push-bar profiles, lengths and elevations; Hardware, threshold, swing and anchorage; Directory case depth and physical world transform; Elevator entrance host-wall thickness, return geometry, rough opening and physical world transform; Independent as-built check.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY P
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: BAY P
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
f1-public-lobby-w217-bay-p-elevator-no2-entranceverified · derived
Elevator No. 2 analytical finished-entrance center · world west/east coordinate
63.454586596548396 ft63.454587 ft
Accepted only for the zero-thickness finished-entrance evidence envelope.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY P; ELEVATOR No. 2
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: BAY P; ELEVATOR NO. 2
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
Calculated from: W217-bay-p-plan-elevator-entrance-center-station, W217-bay-p-W3-rotation-y
f1-public-lobby-w217-bay-p-elevator-no2-entranceverified · derived
Elevator No. 2 analytical finished-entrance center · world south/north coordinate
50.604939757495075 ft50.60494 ft
Accepted only for the zero-thickness finished-entrance evidence envelope.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY P; ELEVATOR No. 2
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: BAY P; ELEVATOR NO. 2
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
Calculated from: W217-bay-p-plan-elevator-entrance-center-station, W217-bay-p-W3-rotation-y
f1-public-lobby-w217-bay-p-elevator-no2-entranceverified · derived
Elevator No. 2 analytical finished-entrance plane rotation about building Y
-1.5873855067559648 rad-1.587386 rad
Zero-thickness elevation plane only.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY P
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: BAY P
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
Calculated from: W217-bay-p-W3-rotation-y
f1-public-lobby-w217-bay-p-elevator-no2-entranceverified · derived
Elevator No. 2 analytical finished-entrance envelope placement
Accepted · zero-thickness evidence review onlyW217 supplies an exact symmetric 24'-11" Bay P plan, a 6-foot central paired door, and a separately chained 3'-6" Elevator No. 2 finished entrance. Centering that exact plan on the independently labeled W3 Bay P wall leaves 1.256-foot endpoint residuals and a 1.468-foot held-out door-center residual, both within W3's recorded 2-foot trace uncertainty. The W3 door trace is only 3.9 feet wide and its south endpoint fails the 2-foot check, so it is treated as an incomplete swing-arc trace and is not used to resize the verified W217 leaves. A separate old W3 line classified as the Elevator No. 2 threshold is 6.957 feet from the W217-predicted entrance center and differs in orientation by 89.695 degrees; targeted review confirms it is not the Bay P-parallel entrance plane, so that provisional trace is disputed and excluded. The checked registration places the zero-thickness analytical door leaves and Elevator No. 2 finished-entrance envelope only; it does not establish physical wall, frame, shaft, cab, or equipment geometry.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY P; ELEVATOR No. 2
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: BAY P; ELEVATOR NO. 2
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
f1-public-lobby-w217-bay-p-elevator-no2-entranceverified · observed
Elevator No. 2 physical entrance/frame/wall-cut placement
WithheldHost-wall thickness, returns, rough opening, jamb/reveal depth, frame construction, sill, doors, shaft, cab and equipment remain unresolved.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY P
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: BAY P
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
f1-door-elevator-2disputed · derived
Rejected earlier W3 threshold-trace center · world west/east coordinate
69.583 ft69.583 ft
Retained only to document the rejected classification; not authoring geometry.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: Earlier provisional threshold trace
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
Calculated from: f1-door-elevator-2-jamb-1-west, f1-door-elevator-2-jamb-2-west
f1-door-elevator-2disputed · derived
Rejected earlier W3 threshold-trace center · world south/north coordinate
47.312 ft47.312 ft
Retained only to document the rejected classification; not authoring geometry.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: Earlier provisional threshold trace
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
Calculated from: f1-door-elevator-2-jamb-1-north, f1-door-elevator-2-jamb-2-north
f1-door-elevator-2verified · derived
Rejected W3 threshold-trace center residual from registered W217 entrance center
6.95707575710492 ft · rejected6.957076 ft
The residual exceeds W3's 2-foot trace allowance; the old trace is not averaged or reused.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY P; ELEVATOR No. 2
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: Earlier provisional threshold trace
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
Calculated from: W217-bay-p-W3-elevator-entrance-world-center-x, W217-bay-p-W3-elevator-entrance-world-center-z, W217-bay-p-W3-elevator-entrance-rejected-trace-center-x, W217-bay-p-W3-elevator-entrance-rejected-trace-center-z
f1-door-elevator-2verified · derived
Rejected W3 threshold-trace acute orientation difference from registered Bay P plane
89.69515759763117° · nearly perpendicular89.695158 deg
Targeted source review confirms that the Elevator No. 2 entrance is parallel to Bay P; the nearly perpendicular trace is misclassified.
IMG_1095 · sheet-W217 · Locate on drawing ↗Drawing notation: PLAN OF BAY P
Full-sheet text and existing reports were read first; the complete sheet and sequential Bay P plan crops were then inspected one image at a time.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: Earlier provisional threshold trace
The W3 registration is provisional. Bay P wall endpoints and the double-door segment are traced plan controls with a conservative 2-foot uncertainty, not surveyed construction faces.
Calculated from: W217-bay-p-W3-elevator-entrance-rotation-y, f1-door-elevator-2-jamb-1-west, f1-door-elevator-2-jamb-1-north, f1-door-elevator-2-jamb-2-west, f1-door-elevator-2-jamb-2-north
main-north-entrance-stepsunreviewed · traced
Registered top run center X
-0.202768 ft · W3 trace-0.202768 ft
Manual W3 pixel [1907,2245] projected through the existing provisional W3 registration.
IMG_1202 · W3 · Locate on drawing ↗Drawing notation: CENTER LINE OF ENTRANCE; Main entrance stair plan; section line A
Targeted W3 Main-entrance crop reviewed after OCR/index and existing stair-package review. Pixel picks are manual plan traces, not printed dimensions.
main-north-entrance-stepsunreviewed · traced
Registered top run center Z
84.650280 ft · W3 trace84.65028 ft
Manual W3 pixel [1907,2245] projected through the existing provisional W3 registration.
IMG_1202 · W3 · Locate on drawing ↗Drawing notation: CENTER LINE OF ENTRANCE; Main entrance stair plan; section line A
Targeted W3 Main-entrance crop reviewed after OCR/index and existing stair-package review. Pixel picks are manual plan traces, not printed dimensions.
main-north-entrance-stepsunreviewed · traced
Registered lower run center X
-0.234744 ft · W3 trace-0.234744 ft
Manual W3 pixel [1907,2589] projected through the existing provisional W3 registration.
IMG_1202 · W3 · Locate on drawing ↗Drawing notation: CENTER LINE OF ENTRANCE; Main entrance stair plan; section line A
Targeted W3 Main-entrance crop reviewed after OCR/index and existing stair-package review. Pixel picks are manual plan traces, not printed dimensions.
main-north-entrance-stepsunreviewed · traced
Registered lower run center Z
109.630881 ft · W3 trace109.630881 ft
Manual W3 pixel [1907,2589] projected through the existing provisional W3 registration.
IMG_1202 · W3 · Locate on drawing ↗Drawing notation: CENTER LINE OF ENTRANCE; Main entrance stair plan; section line A
Targeted W3 Main-entrance crop reviewed after OCR/index and existing stair-package review. Pixel picks are manual plan traces, not printed dimensions.
main-north-entrance-stepsunreviewed · traced
Registered rear landing reference X
-0.197513 ft · W3 trace-0.197513 ft
Manual W3 pixel [1907,2190] projected through the existing provisional W3 registration.
IMG_1202 · W3 · Locate on drawing ↗Drawing notation: CENTER LINE OF ENTRANCE; Main entrance stair plan; section line A
Targeted W3 Main-entrance crop reviewed after OCR/index and existing stair-package review. Pixel picks are manual plan traces, not printed dimensions.
main-north-entrance-stepsunreviewed · traced
Registered rear landing reference Z
80.545140 ft · W3 trace80.54514 ft
Manual W3 pixel [1907,2190] projected through the existing provisional W3 registration.
IMG_1202 · W3 · Locate on drawing ↗Drawing notation: CENTER LINE OF ENTRANCE; Main entrance stair plan; section line A
Targeted W3 Main-entrance crop reviewed after OCR/index and existing stair-package review. Pixel picks are manual plan traces, not printed dimensions.